文献速递骨肌MR

基于同步多层采集与深度学习重建加速的膝关节MRI协议的真实世界诊断性能

Real-world diagnostic performance of knee MRI protocols accelerated using simultaneous multi-slice acquisition and deep learning reconstruction.
PubMed 文献 · Skeletal Radiol · 2025-10-19

这项回顾性队列研究纳入1055例在180天内接受膝关节MRI和关节镜检查的患者,比较传统协议、SMS加速协议和SMS联合DLR协议对半月板及前交叉韧带撕裂的诊断性能。加速协议在ACL撕裂敏感度上高于传统协议且非劣效性成立,MM敏感度和LM特异度也满足非劣效性,但MM特异度和LM敏感度未达到严格非劣效界值,所有指标均无统计学显著下降。

要点

  • SMS和DLR加速协议对ACL撕裂敏感度高于传统协议(0.96和0.98 vs 0.85),非劣效性成立。
  • MM敏感度0.94-0.95满足非劣效性,但MM特异度0.88-0.91和LM敏感度0.63-0.68未达到非劣效界值。
  • 所有协议各指标间均无统计学显著下降,支持加速协议用于高通量膝关节成像。

核心结论

  • 使用SMS和DLR的加速MRI协议诊断性能与传统参考协议相当;虽非所有指标满足严格非劣效界值,但敏感度和特异度均无统计学显著降低,支持临床采用加速协议实现更快的高通量膝关节成像。

研究设计与样本

  • 回顾性队列研究,纳入1055例在膝关节MRI后180天内行关节镜检查的患者,分为传统协议组(n=226)、SMS加速协议组(n=406)和SMS联合DLR协议组(n=423),每组均为连续检查;采用3 T MRI和五个标准化二维快速自旋回波序列,以关节镜为参考标准。

诊断标准与关键数值

  • 以关节镜为参考标准计算ACL、MM和LM撕裂的敏感度与特异度及95%CI(非参数自举法);非劣效性界值为敏感度和特异度差值的95%CI上限≤0.05;ACL撕裂敏感度加速协议为0.96和0.98、传统协议为0.85,非劣效性成立;所有协议特异度≥0.98;MM敏感度0.94-0.95满足非劣效性,MM特异度0.88-0.91未达非劣效界值;LM敏感度0.63-0.68未达非劣效界值,LM特异度0.94满足非劣效性。

临床应用与阅片要点

  • 原文结论支持加速协议用于更快的高通量膝关节成像;原文未据此给出具体阅片建议。

局限性

  • 原文为回顾性队列研究。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess whether accelerated knee MRI protocols using simultaneous multi-slice (SMS) and deep learning reconstruction (DLR) are non-inferior to a conventional parallel imaging protocol for detecting internal derangement injuries.

METHODS: This retrospective cohort study included 1055 patients who underwent knee MRI followed by arthroscopy within 180 days. Patients were scanned using either a conventional protocol (n = 226), an accelerated SMS protocol (n = 406), or a SMS with DLR protocol (n = 423). Each group included consecutive exams. Imaging was performed on 3 T MRI using five standardized two-dimensional turbo spin echo sequences. Radiology interpretations were compared with arthroscopy (reference standard) for anterior cruciate ligament (ACL), medial meniscus (MM), and lateral meniscus (LM) tears. Sensitivity and specificity were calculated with 95% confidence intervals using non-parametric bootstrapping. Non-inferiority was concluded if the upper bound of the 95% confidence interval for the difference in sensitivity and specificity was ≤ 0.05.

RESULTS: Among all patients, 666 had MM tears, 417 had LM tears, and 220 had ACL tears. Sensitivity for ACL tears was higher with accelerated protocols (0.96 and 0.98) than the conventional (0.85), with non-inferiority confirmed. Specificity was ≥ 0.98 across all protocols. MM sensitivity (0.94-0.95) met non-inferiority criteria. MM specificity (0.88-0.91) and LM sensitivity (0.63-0.68) were not statistically different across protocols but did not meet the non-inferiority margin. LM specificity (0.94) met non-inferiority criteria.

CONCLUSION: Accelerated MRI protocols using SMS and DLR demonstrated comparable diagnostic performance to the reference protocol. Although not all metrics met the strict non-inferiority margin, none showed statistically significant reductions in sensitivity or specificity. These findings support the clinical adoption of accelerated protocols for faster, high-throughput knee imaging.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Johnson PM, Dogra S, Westerhoff M, et al. Real-world diagnostic performance of knee MRI protocols accelerated using simultaneous multi-slice acquisition and deep learning reconstruction. Skeletal Radiol. 2025. PMID: 41109866. doi:10.1007/s00256-025-05058-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。