影响颈部淋巴结超声引导空芯针活检诊断率的临床与超声因素
回顾性研究评估136例颈部淋巴结病变超声引导空芯针活检的诊断率,淋巴增殖性疾病95例(69.8%)、反应性淋巴结24例(17.6%)、癌17例(12.5%);初始活检非诊断性24例(17.6%),淋巴结较大与诊断率较高相关(P<0.01),较小淋巴结及存在脂肪门与诊断率降低相关。
要点
- 淋巴结较大与超声引导空芯针活检诊断率较高相关(P<0.01)。
- 较小淋巴结及存在脂肪门与诊断率降低相关。
- 针径(P=0.13)、邻近大血管(P=0.68)、过冲可能性(P=0.26)与诊断率无相关性。
核心结论
- 较小淋巴结及存在脂肪门与超声引导空芯针活检诊断率降低相关,具有不利特征的患者可考虑影像监测、细针穿刺(FNA)或开放活检。
研究设计与样本
- 单中心回顾性研究,纳入136例颈部淋巴结病变患者,评估超声引导空芯针活检,两位放射科医生从正式操作报告和超声图像采集数据,并与组织病理报告进行关联。
诊断标准与关键数值
- 最终诊断:淋巴增殖性疾病95例(69.8%)、反应性淋巴结24例(17.6%)、癌17例(12.5%)。
- 初始活检非诊断性24例(17.6%),其中17例最终为反应性淋巴结,7例为淋巴增殖性疾病。
- 所有癌病例均在初始活检中检出。
- 淋巴结较大与诊断率较高相关(P<0.01)。
- 针径(P=0.13)、邻近大血管(P=0.68)、过冲可能性(P=0.26)与诊断率无相关性。
临床应用与阅片要点
- 较小淋巴结及存在脂肪门与超声引导空芯针活检诊断率降低相关。
- 具有不利特征的患者可考虑影像监测、细针穿刺(FNA)或开放活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Cervical lymphadenopathy can indicate various benign or malignant conditions. While ultrasound-guided core biopsy is commonly used for diagnosis, its effectiveness can vary. Our study aimed to determine factors that affect the diagnostic yield of this procedure, potentially guiding appropriate patient referrals towards either more invasive diagnostic procedures, such as open biopsy or less intensive approaches like ongoing follow-up.
MATERIALS AND METHODS: A retrospective study was conducted evaluating ultrasound-guided core biopsies performed for cervical lymphadenopathy at a single institution. Imaging features and technical details were documented. Two radiologists collected data from formal procedure reports and recorded sonographic images. Data were then correlated with histopathologic reports.
RESULTS: The study included 136 patients with final diagnoses of lymphoproliferative disease (95 patients, 69.8%), reactive lymphadenopathy (24 patients, 17.6%), and carcinoma (17 patients, 12.5%). Twenty-four of the initial biopsies were nondiagnostic (17.6%), requiring diagnosis through surgery, follow-up, or repeated biopsy. Of the 24 nondiagnostic biopsies, 17 were eventually identified as reactive lymph nodes, and 7 harboured lymphoproliferative disease. All carcinoma cases were detected on the initial biopsy. Larger lymph node size correlated with higher diagnostic yield (P < 0.01). No correlation was found with needle gauge (P = 0.13), proximity to large vessels (P = 0.68), or overshoot potential (P = 0.26).
CONCLUSION: Our study results show that smaller lymph node size and the presence of a fatty hilum are correlated with reduced diagnostic yield. Patients with unfavourable characteristics should be considered for imaging surveillance, fine-needle aspiration (FNA), or an open biopsy.
引用
- Yahav-Dovrat A, Saban M, Merhav G, et al. Clinical and sonographic factors influencing diagnostic yield of ultrasound-guided core biopsy of cervical lymph nodes. Clin Radiol. 2025. PMID: 41086708. doi:10.1016/j.crad.2025.107093
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。