术前临床评分与双能CT参数预测晚期高级别浆液性卵巢癌完全切除术的比较
研究纳入56例晚期高级别浆液性卵巢癌患者,比较Suidan评分、CT-PCI、CT-Eisenkop评分、Aletti评分与双能CT参数预测R0切除的效能。VMI40(VP-AP)/AP比值是R0预测的唯一独立危险因素(OR 0.019,P=0.022),AUC为0.724;CT-Eisenkop评分联合VMI40(VP-AP)/AP的AUC最高(0.853,敏感度94.7%,特异度69.0%)。
要点
- VMI40(VP-AP)/AP比值是预测R0切除的唯一独立危险因素(OR 0.019,P=0.022)。
- VMI40(VP-AP)/AP比值预测R0的AUC为0.724,与CT-PCI及CT-Eisenkop评分(AUC均为0.722)相当。
- CT-Eisenkop评分联合VMI40(VP-AP)/AP的AUC最高(0.853,敏感度94.7%,特异度69.0%)。
核心结论
- 双能CT参数VMI40(VP-AP)/AP比值预测晚期HGSC患者R0切除的效能优于传统CT-based临床评分,联合CT-Eisenkop评分可进一步提高预测准确性。
研究设计与样本
- 研究纳入2021年11月至2024年7月间56例具有完整双能CT图像和临床病理信息的晚期HGSC患者,评估Suidan评分、CT-PCI、CT-Eisenkop评分和Aletti评分,并前瞻性收集手术结局;双能CT参数于两期增强图像的实性原发肿瘤成分上测量,采用ROC曲线和logistic回归分析评估R0预测的诊断效能。
诊断标准与关键数值
- VMI40(VP-AP)/AP比值预测R0切除的AUC为0.724;CT-PCI和CT-Eisenkop评分预测R0的AUC均为0.722;CT-Eisenkop评分联合VMI40(VP-AP)/AP预测R0的AUC为0.853,敏感度94.7%,特异度69.0%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: The aim of this study was to compare clinical scores with dual-energy computed tomography (CT) parameters of ovarian advanced high-grade serous carcinoma (HGSC) in prediction of complete (R0) resection.
MATERIALS AND METHODS: Between November 2021 and July 2024, 56 advanced HGSC patients with complete dual-energy CT images and clinicopathological information were enrolled. Clinical scores, including the Suidan score, computed tomography-based peritoneal cancer index (CT-PCI), computed tomography-based Eisenkop (CT-Eisenkop) score, and Aletti score, were evaluated, and surgical outcomes were prospectively collected. Dual-energy CT parameters were measured from the solid primary tumour component in two-phase contrast-enhanced images. Receiver operating characteristic curves and logistic regression analysis were used to evaluate the diagnostic efficacy in predicting R0 resection.
RESULTS: Of the 56 advanced HGSC patients, 32 (57.14%) had R0 resection and 24 (42.86%) had tumour residue. Virtual monoenergetic images at 40 keV (VMI40) were analysed using the ratio of venous phase (VP) to arterial phase (AP) enhancement, expressed as (VP-AP)/AP. The VMI40 (VP-AP)/AP ratio was identified as the only independent risk factor for R0 prediction (odds ratio: 0.019; P=0.022). The VMI40 (VP-AP)/AP ratio showed considerable area under the curve (AUC) performance (AUC of 0.724) for R0 resection, as did the CT-PCI and the CT-Eisenkop scores (both with an AUC of 0.722), compared to the Suidan score. Using CT-Eisenkop score + VMI40 (VP-AP)/AP showed the highest AUC for R0 resection (AUC: 0.853, sensitivity: 94.7%, and specificity: 69.0%).
CONCLUSION: The VMI40 (VP-AP/AP) ratio, a dual-energy CT parameter, outperforms traditional CT-based clinical scores for predicting R0 resection in advanced HGSC. Predictive accuracy is further improved when combined with the CT-Eisenkop score.
引用
- Song J, Jiang X, Zhang A, et al. Preoperative clinical scores compared with dual-energy computed tomography parameters in predicting complete resection of ovarian advanced high-grade serous carcinoma. Clin Radiol. 2025. PMID: 41151412. doi:10.1016/j.crad.2025.107104
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。