MRI影像组学对高强度聚焦超声(HIFU)消融子宫肌瘤疗效的预测价值:一项系统综述与Meta分析
该系统综述与Meta分析纳入13项研究,评估基于MRI的影像组学机器学习模型预测HIFU消融子宫肌瘤疗效的表现。7个内部验证和6个外部验证队列共608例患者的汇总AUC为0.84,敏感度77%,特异度78%。QUADAS-2显示索引测试及流程与时机领域存在显著方法学偏倚,METRICS平均分76.93%(范围54.9%-90.3%)。
要点
- MRI影像组学模型预测HIFU消融子宫肌瘤疗效的汇总AUC为0.84。
- 汇总敏感度77%、特异度78%,来自7个内部和6个外部验证队列共608例患者。
- QUADAS-2提示索引测试及流程与时机领域存在显著方法学偏倚。
核心结论
- 基于MRI的影像组学模型在预测子宫肌瘤HIFU消融有效性方面显示出前景,但地理多样性有限、报告标准不一致和开放科学实践不足等局限妨碍更广泛应用。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Scopus、Embase和Web of Science至2025年6月,纳入13项研究,采用QUADAS-2和METRICS工具评估质量,使用双变量随机效应模型汇总敏感度、特异度和AUC。
诊断标准与关键数值
- 7个内部验证和6个外部验证队列共608例患者,汇总AUC为0.84,汇总敏感度为77%,汇总特异度为78%。
局限性
- QUADAS-2显示索引测试及流程与时机领域存在显著方法学偏倚。
- 所有研究的METRICS平均分为76.93%,范围为54.9%-90.3%,开放科学领域存在明显不足。
- 地理多样性有限。
- 报告标准不一致。
- 开放科学实践不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
High-Intensity Focused Ultrasound (HIFU) ablation has emerged as a non-invasive treatment option for uterine fibroids that preserves fertility and offers faster recovery. Pre-intervention prediction of HIFU efficacy can augment clinical decision-making and patient management. This systematic review and meta-analysis aims to evaluate the performance of MRI-based radiomics machine learning (ML) models in predicting the efficacy of HIFU ablation in uterine fibroids. Studies were retrieved by conducting a thorough literature search across databases including PubMed, Scopus, Embase, and Web of Science, up to June 2025. The quality of the included studies was assessed using the QUADAS-2 and METRICS tools. A meta-analysis of the radiomics models was conducted to pool sensitivity, specificity, and AUC using a bivariate random-effects model. A total of 13 studies were incorporated in the systematic review and meta-analysis. Meta-analysis of 608 patients from 7 internal and 6 external validation cohorts showed pooled AUC, sensitivity, and specificity of 0.84, 77%, and 78%, respectively. QUADAS-2 was notable for significant methodological biases in the index test and flow and timing domains. Across all studies, the mean METRICS score was 76.93%-with a range of 54.9%-90.3%-denoting good overall quality and performance in most domains but with notable gaps in the open science domain. MRI-based radiomics models show promise in predicting the effectiveness of HIFU ablation for uterine fibroids. However, limitations such as limited geographic diversity, inconsistent reporting standards, and poor open science practices hinder broader application. Therefore, future research should focus on standardizing imaging protocols, using multi-center designs with external validation, and integrating diverse data sources.
引用
- Salimi M, Abdolizadeh A, Fayedeh F, et al. Predictive Value of MRI Radiomics for the Efficacy of High-Intensity Focused Ultrasound (HIFU) Ablation in Uterine Fibroids: A Systematic Review and Meta-Analysis. Ultrasound Med Biol. 2025. PMID: 41027762. doi:10.1016/j.ultrasmedbio.2025.09.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。