文献速递泌尿生殖MR

实施双参数前列腺MRI方案并设立静脉造影剂召回系统:召回率分析及PI-RADS分类分布比较

Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution.
PubMed 文献 · Abdom Radiol (NY) · 2025-10-09

单中心将前列腺MRI从增强多参数方案改为非增强双参数方案后,554例中547例纳入,36例(6.6%)因需静脉造影剂被召回,其中91.7%为PI-RADS 3再评估;召回中位时间35天。方案实施前后各225例的PI-RADS分类分布无统计学显著差异(卡方检验 P=0.09),放射科医师报告频率分布亦无显著差异(P=0.06)。

要点

  • 双参数MRI方案下仅6.6%受检者需召回增强,绝大多数(91.7%)为PI-RADS 3再评估。
  • 召回后48.5%(16/33)的PI-RADS 3病例升级为PI-RADS 4。
  • 方案实施前后PI-RADS分类分布无统计学显著差异(P=0.09)。

核心结论

  • 单中心实施双参数前列腺MRI方案后,少数受检者(6.6%)因造影剂再评估被召回,其中多数(91.7%)为PI-RADS 3再评估;方案实施后PI-RADS分类分布无统计学显著差异,在未改变PI-RADS分布的同时减少了患者静脉造影剂暴露。

研究设计与样本

  • 回顾性描述性研究,单中心,连续纳入方案变更后(2023年4月1日至2024年5月23日)全部3T前列腺双参数MRI共554例、纳入547例(96.8%);第2部分将其中225例与方案变更前连续样本225例比较PI-RADS分类分布,并比较实施前后放射科医师报告频率分布。

诊断标准与关键数值

  • 召回指征为需静脉造影剂再评估;547例中36例(6.6%)被召回,其中33/36(91.7%)为PI-RADS 3再评估;33例PI-RADS 3中16例(48.5%)升级为PI-RADS 4;初次与召回MRI中位间隔35天。

临床应用与阅片要点

  • 实施双参数前列腺MRI方案并设立静脉造影剂召回系统后,PI-RADS 3再评估是召回的主要原因,召回后近半数病例升级为PI-RADS 4。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The prostate magnetic resonance imaging (MRI) protocol changed from a contrast multiparametric MRI (mp-MRI) to a non-contrast biparametric (bp-MRI) protocol at a single centre. This study describes the recall rate, median time to recall, and PI-RADS distribution pre-/post-implementation.

METHODS: This retrospective descriptive study involved a consecutive sample of all 3 Tesla (3T) prostate bp-MRIs following the protocol change (01April2023-23May2024) to determine the proportion of bp-MRIs recalled, the indications for recall, and the median time until recall MRI (Part 1). A subset of these prostate MRIs was compared to a consecutive sample immediately prior to the change in protocol to compare the distribution of PI-RADS categories (Part 2). The distribution of MRI reporting frequency by radiologists was compared pre-/post-implementation (Part 2).

INCLUSION CRITERIA: 3T bp-MRI protocol, out-patient, male, and ≥ 18 years of age.

RESULTS: A total of 554 prostate bp-MRIs took place during the study period, 547 (96.8%) were included. Of the 547 subjects, 36 (6.6%) were recalled for intravenous (IV) contrast. Most recalls were for PI-RADS 3 reassessment (33/36, 91.7%). PI-RADS categories were upgraded from 3 to 4 in 16/33 (48.5%) subjects. The median time between initial and recall MRI was 35 days. There was no statistically significant difference in the distribution of PI-RADS categories before (n = 225) and after (n = 225) implementation of the bp-MRI protocol (X2, p = 0.09). There was no statistically significant difference in the distribution of MRI reporting frequency by radiologists pre-/post-implementation (X2, p = 0.06).

CONCLUSION: A small proportion (6.6%) of bp-MRI subjects were recalled for contrast reassessment and the majority of those (91.7%) were for PI-RADS 3 reassessment. There was no statistically significant difference in the distribution of PI-RADS categories following implementation of the bp-MRI protocol. Implementation of a bp-MRI protocol at a single centre reduced patient exposure to IV contrast while not changing PI-RADS distribution.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Brown JD, Payne J, Clarke SE, et al. Implementation of a biparametric prostate MRI protocol with a recall system for intravenous contrast: an analysis of recall rates and comparison of PI-RADS category distribution. Abdom Radiol (NY). 2025. PMID: 41065830. doi:10.1007/s00261-025-05223-0