扫描参数对5 T MRI肾脏血氧水平依赖成像图像质量和可重复性的影响:一项初步研究

Influence of scanning parameters on image quality, and repeatability of renal blood oxygenation level-dependent imaging: A preliminary study on 5 T MRI.
PubMed 文献 · Eur J Radiol · 2025-09-27

该前瞻性研究纳入20名健康受试者和25例慢性肾脏病患者,在5 T MRI上采用多组参数行肾脏BOLD成像,评估扫描参数对图像质量和R2*值可重复性的影响。高分辨率参数(1.25 mm×1.25 mm×3 mm)提供更优的皮髓质分界和临床图像质量,R2*值观察者间一致性高且重测可重复性好。慢性肾脏病患者肾皮质和髓质R2*值均显著高于健康受试者。

要点

  • 5 T肾脏BOLD-MRI中,层厚对皮质和髓质R2*值均有显著正向影响。
  • 最大回波时间仅对皮质R2*值有区域特异性正向影响。
  • 高分辨率BOLD成像(1.25 mm×1.25 mm×3 mm,10个回波,最大TE 40 ms)观察者间一致性和重测可重复性均优。

核心结论

  • 图像分辨率可能轻微影响5 T肾脏BOLD-MRI的R2*值定量;高分辨率BOLD成像在5 T MRI上可实现优异的观察者间一致性和重测可重复性,验证了其临床适用性。

研究设计与样本

  • 前瞻性研究,纳入20名健康受试者和25例慢性肾脏病患者,在5 T MRI上采用多组参数组合行肾脏BOLD-MRI扫描,以R2*值定量为参考指标。

关键影像表现/征象

  • 高分辨率参数(1.25 mm×1.25 mm×3 mm)提供更优的皮髓质分界和临床图像质量。
  • 肾皮质和髓质R2*值在不同平面内分辨率、层厚、回波数和最大TE下均具有优异一致性(所有ICC均>0.75)。
  • 与健康受试者相比,慢性肾脏病患者肾皮质R2*值显著更高(21.13 Hz vs. 22.88 Hz,P<0.001)。
  • 与健康受试者相比,慢性肾脏病患者肾髓质R2*值显著更高(40.69 Hz vs. 49.14 Hz,P<0.001)。

诊断标准与关键数值

  • 高分辨率BOLD成像参数为1.25 mm×1.25 mm×3 mm,10个回波,最大TE 40 ms。
  • 高分辨率下肾皮质和髓质R2*值的观察者间一致性ICC分别为0.992和0.971。
  • 高分辨率下肾皮质和髓质R2*值的重测可重复性均为r>0.90(P<0.05)。
  • 不同平面内分辨率、层厚、回波数和最大TE下肾皮质和髓质R2*值的一致性均为ICC>0.75。

临床应用与阅片要点

  • 在5 T肾脏BOLD-MRI中,层厚对皮质和髓质R2*值均有显著正向影响,阅片和定量时需注意层厚设置。
  • 最大回波时间仅对皮质R2*值有显著正向影响,对髓质R2*值无显著影响。
  • 平面内分辨率和回波数对R2*值无显著影响。
  • 作者指出高分辨率BOLD成像(1.25 mm×1.25 mm×3 mm,10个回波,最大TE 40 ms)在5 T MRI上可实现优异的观察者间一致性和重测可重复性,验证了其临床适用性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the influence of scanning parameters on image quality and the repeatability of renal Blood Oxygenation Level-Dependent (BOLD) imaging at 5 T.

METHODS: 20 healthy subjects and 25 patients with chronic kidney disease (CKD) were prospectively recruited for BOLD-MRI scans at 5 T using multiple parameter combinations. The Fisher's exact test, ANOVA, the Friedman test, and paired t-tests were used to compare the qualitative and quantitative indices across groups. The generalized linear models (GLM) analysis was further used to evaluate the effect of acquisition parameters on the measured R2* values. Subsequently, Pearson correlation and the intraclass correlation coefficient (ICC) were applied to assess the repeatability of R2* values in the high-resolution parameters in patients.

RESULTS: Renal cortical and medullary R2* values demonstrated excellent agreement (all ICCs > 0.75) across varied in-plane resolution, slice thickness, echo number, and maximum TE. GLM revealed a significant positive effect of slice thickness on R2* in both cortex and medulla, a region-specific positive effect of maximum TE in the cortex only, and no significant effect of in-plane resolution or echo number. High resolution (1.25 mm × 1.25 mm × 3 mm) provided superior corticomedullary demarcation and clinical image quality, and renal cortical and medullary R2* values exhibited high inter-observer agreement (ICC: 0.992 and 0.971) and test-retest repeatability (all r > 0.90, P < 0.05). Compared with healthy subjects, the renal cortical and medullary R2* values in patients with CKD were significantly higher (cortical R2*: 21.13 Hz vs. 22.88 Hz, P < 0.001; medullary R2*: 40.69 Hz vs. 49.14 Hz, P < 0.001).

CONCLUSION: This study showed that image resolution may slightly affect the quantification of the R2* values on 5 T renal BOLD-MRI. High-resolution BOLD imaging (1.25 mm × 1.25 mm × 3 mm, 10 echoes, maximum TE 40 ms) can be achieved at 5 T MRI with excellent inter-observer agreement and test-retest repeatability, validating its clinical applicability.