提升MR细胞术在前列腺癌影像中的诊断效能
本研究纳入33例前列腺癌与39例良性病变患者,行脉冲梯度自旋回波和振荡梯度自旋回波(20 Hz与40 Hz)扩散MRI,采用单指数信号拟合消除灌注效应,计算ADC、MR细胞术微结构参数(细胞直径、细胞内体积分数、细胞外扩散率、细胞密度)及直方图特征,比较其鉴别良恶性病变的诊断效能。消除灌注效应与引入直方图特征均可提高联合回归模型的AUC(由0.885分别升至0.918和0.908),两者结合后AUC进一步提升至0.934。
要点
- 消除灌注效应后细胞直径在良恶性组间差异的显著性水平提高,良性组细胞直径更大。
- 单一参数直方图特征的诊断效能与对应ADC或微结构参数均值相当。
- 消除灌注效应并纳入ADC及微结构参数的直方图特征可提高鉴别诊断效能,联合模型AUC达0.934。
核心结论
- 在MR细胞术分析中,消除灌注效应并纳入ADC和微结构参数的直方图特征可提供更好的诊断效能,联合策略使AUC由0.885提升至0.934。
研究设计与样本
- 研究纳入33例前列腺癌患者和39例良性病变患者,均行时间依赖扩散MRI检查,包括脉冲梯度自旋回波扩散加权成像及频率20 Hz与40 Hz的振荡梯度自旋回波扩散加权成像;采用单指数信号拟合方法消除灌注效应,计算ADC、MR细胞术衍生的微结构参数(细胞直径、细胞内体积分数、细胞外扩散率、细胞密度)及相应直方图特征以鉴别病变。
诊断标准与关键数值
- 采用Mann-Whitney U检验评估良恶性病变间差异,行单变量和多变量logistic回归并计算受试者工作特征曲线下面积(AUC)量化分类器诊断性能;消除灌注效应使细胞直径差异的显著性水平提高,良性组细胞直径更大。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the improved diagnostic efficacy of the emerging non-invasive microstructure imaging technique, MR cytometry, in differentiating benign and malignant prostate lesions, after removing perfusion effect and introducing histogram features.
METHODS: This study included 33 patients with prostate cancer and 39 patients with benign lesions, who underwent time-dependent diffusion MRI examinations, including pulsed gradient spin-echo (PGSE) diffusion-weighted imaging (DWI) and oscillating gradient spin-echo (OGSE) DWI at frequencies of 20 Hz and 40 Hz. A mono-exponential signal-fitting method was used to eliminate perfusion effects. Apparent diffusion coefficients (ADC), MR-cytometry-derived microstructural parameters (cell diameter [Formula: see text], intracellular volume fraction [Formula: see text], extracellular diffusivity [Formula: see text] and cellularity [Formula: see text]) and corresponding histogram features were calculated to differentiate lesions. Mann-Whitney U-tests were used to evaluate the differences between benign and malignant lesions. Uni- and multi-variate logistic regressions were performed and calculated the area under the receiver operating characteristic (AUC) to quantify the diagnostic performance of classifiers.
RESULTS: Removal of perfusion effect improved the significance level of the difference in the cell diameter [Formula: see text] (from [Formula: see text] to [Formula: see text]), where [Formula: see text] is larger in the benign group. The diagnostic efficacy of a single histogram feature was comparable to that of the corresponding ADC or microstructural parameter mean value. Both removing perfusion effect and incorporating histogram features can improve the AUC of the combined regression models (from 0.885 to 0.918 and 0.908, respectively). Combining both strategies further enhanced the AUC to 0.934.
CONCLUSION: In MR cytometry analysis, removing the perfusion effect and incorporating histogram features of ADCs and microstructural parameters can provide better diagnostic efficacy.
引用
- Zhang J, Liu F, Peng Q, et al. Improving the diagnostic efficacy of MR cytometry in prostate cancer imaging. Abdom Radiol (NY). 2025. PMID: 41171409. doi:10.1007/s00261-025-05240-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。