文献速递腹部技术与安全US

基于对比增强超声获得的微泡破坏曲线有助于评估MASLD患者的肝纤维化并识别高风险MASH

The Bubble-Destruction Curve Obtained Using Contrast-Enhanced Ultrasound is Useful for Assessing Liver Fibrosis and Identifying At-risk MASH in Patients With MASLD.
PubMed 文献 · Ultrasound Med Biol · 2025-10-28

本研究纳入95例经活检证实MASLD的患者,采用Sonazoid行对比增强超声,在血管后(Kupffer)期行Flash成像生成微泡破坏曲线。结果显示微泡破坏深度与组织学纤维化分期、剪切波弹性成像及FIB-4指数显著相关,诊断肝硬化(F4)的AUC为0.92;联合BDD、AST和性别的AS-BDD-MASH评分识别高风险MASH的AUC为0.847。

要点

  • 微泡破坏深度与组织学纤维化分期、剪切波弹性成像和FIB-4指数显著相关。
  • 微泡破坏深度诊断肝硬化(F4)的AUC为0.92。
  • AS-BDD-MASH评分(BDD+AST+性别)识别高风险MASH的AUC为0.847。

核心结论

  • 对比增强超声衍生的微泡破坏曲线是评估MASLD患者肝纤维化的可行且准确的方法,联合BDD、AST和性别的复合模型对识别高风险MASH具有良好诊断准确性。

研究设计与样本

  • 单中心研究,纳入95例经活检证实的MASLD患者,使用Sonazoid行对比增强超声,于血管后(Kupffer)期行Flash成像生成微泡破坏曲线,计算微泡破坏深度、微泡破坏斜率和微泡累积量三个参数,并与组织学纤维化分期、血液生物标志物、弹性成像参数及高风险MASH的存在进行相关性分析。

诊断标准与关键数值

  • 微泡破坏深度诊断肝硬化(F4)的受试者工作特征曲线下面积为0.92。
  • AS-BDD-MASH评分(微泡破坏深度+AST+性别)识别高风险MASH的受试者工作特征曲线下面积为0.847。
  • 微泡破坏深度与组织学纤维化分期、剪切波弹性成像及FIB-4指数显著相关。

临床应用与阅片要点

  • 可利用对比增强超声血管后(Kupffer)期Flash成像生成的微泡破坏曲线参数微泡破坏深度无创评估MASLD患者肝纤维化。
  • 可参考AS-BDD-MASH评分(微泡破坏深度+AST+性别)识别高风险MASH。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Metabolic-dysfunction-associated steatotic liver disease (MASLD) and its progressive form, metabolic-dysfunction-associated steatohepatitis (MASH), are becoming increasingly prevalent, with liver fibrosis (FIB) being a predictor of poor prognosis. Non-invasive tools for assessment of FIB and early detection of at-risk MASH are essential for effective clinical management. This study evaluated the clinical usefulness of a novel ultrasound (US)-based analytical tool, the bubble-destruction curve, which is derived using contrast-enhanced US (CEUS), for non-invasive assessment of liver FIB and identification of at-risk MASH in patients with MASLD.

METHODS: Ninety-five patients with biopsy-proven MASLD underwent CEUS using Sonazoid as the contrast agent. Flash imaging was performed during the post-vascular (Kupffer) phase to generate the bubble-destruction curve, which calculates three parameters: bubble-destruction depth (BDD), bubble-destruction slope and amount of bubble accumulation. These values were analyzed in relation to histological staging of FIB, blood biomarkers, elastography parameters and the presence of at-risk MASH.

RESULTS: BDD showed a significant correlation with histological FIB stage, shear wave elastography and the FIB-4 index. The diagnostic performance of BDD for cirrhosis (F4) yielded an area under the curve of 0.92. A predictive model that combines BDD, aspartate aminotransferase (AST) and sex, called the AS-BDD-MASH score, demonstrated high diagnostic accuracy for at-risk MASH, with an area under the receiver-operating characteristic curve of 0.847.

CONCLUSION: The bubble-destruction curve derived from CEUS is a feasible and accurate approach for evaluating liver FIB in patients with MASLD. Furthermore, a composite model combining BDD derived from the bubble-destruction curve with AST and sex demonstrated good diagnostic accuracy for identifying at-risk MASH.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Wakui N, Ogino Y, Kamiyama N, et al. The Bubble-Destruction Curve Obtained Using Contrast-Enhanced Ultrasound is Useful for Assessing Liver Fibrosis and Identifying At-risk MASH in Patients With MASLD. Ultrasound Med Biol. 2025. PMID: 41152066. doi:10.1016/j.ultrasmedbio.2025.09.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。