文献速递腹部技术与安全PETCT

食管和胃食管交界处偶发18F-FDG PET/CT摄取:何时需要上消化道内镜检查

Incidental esophageal and gastroesophageal junction uptake on ¹8F-FDG PET/CT: when is upper endoscopy warranted?
PubMed 文献 · Abdom Radiol (NY) · 2025-10-24

本研究纳入106例因食管或胃食管交界处偶发摄取而推荐内镜的患者,评估18F-FDG PET/CT特征鉴别恶性与非恶性病变的价值。恶性病变更常表现为孤立中段食管摄取、偏心性摄取及CT壁增厚或肿块,病灶SUVmax/肝脏SUVmean的AUC为0.94。具备五种特征中至少一种时敏感度100%、特异度65.6%,具备至少两种时特异度升至94.6%而敏感度保持100%。

要点

  • 食管或胃食管交界处偶发摄取若出现局灶性、偏心性、孤立中段食管摄取、病灶SUVmax/肝脏SUVmean≥2.8或CT壁增厚/肿块,需内镜评估。
  • 具备上述五种特征中至少一种对恶性病变敏感度100%、特异度65.6%;具备至少两种时特异度94.6%、敏感度100%。
  • Barrett食管与良性病变的18F-FDG PET/CT特征无显著差异。

核心结论

  • 食管或胃食管交界处偶发18F-FDG PET/CT摄取中出现五种影像特征中任意一种,均需内镜检查。

研究设计与样本

  • 研究纳入2009年1月至2023年7月间全身18F-FDG PET/CT报告记录食管或胃食管交界处偶发摄取并推荐上消化道内镜、且PET扫描后一年内接受上消化道内镜的患者,排除已知食管或胃食管交界处癌者,共106例(良性病变82例、Barrett食管11例、恶性肿瘤13例),以內镜和病理诊断分类。

关键影像表现/征象

  • 恶性病变孤立中段食管摄取出现率30.8%,高于Barrett食管和良性病变的2.2%(P=0.048)。
  • 恶性病变偏心性摄取出现率38.5%,高于Barrett食管和良性病变的2.2%(P<0.001)。
  • 恶性病变CT壁增厚或肿块出现率92.4%,高于Barrett食管和良性病变的15.1%(P<0.001)。
  • Barrett食管与良性病变的18F-FDG PET/CT特征无显著差异。

诊断标准与关键数值

  • 病灶SUVmax/肝脏SUVmean预测恶性病变的曲线下面积为0.94。
  • 具备以下五种特征中至少一种时,对恶性病变敏感度100%、特异度65.6%、阳性预测值28.9%:局灶性摄取、偏心性摄取、孤立中段食管摄取、病灶SUVmax/肝脏SUVmean≥2.8、CT壁增厚或肿块。
  • 具备上述五种特征中至少两种时,特异度升至94.6%,敏感度保持100%。

临床应用与阅片要点

  • 报告食管或胃食管交界处偶发摄取时,应描述摄取位置、模式(弥漫、节段或局灶)、偏心性(环形或偏心)、最大和平均标准化摄取值及CT表现(正常、壁增厚或肿块)。
  • 出现局灶性摄取、偏心性摄取、孤立中段食管摄取、病灶SUVmax/肝脏SUVmean≥2.8或CT壁增厚/肿块中任意一种时,需建议内镜评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To identify imaging features that differentiate malignant lesions from non-malignant conditions associated with incidental uptake in the esophagus and gastroesophageal junction (GEJ) on 18F-FDG PET/CT.

METHODS: Patients were included if they (1) underwent whole-body 18F-FDG PET/CT between January 2009 and July 2023, with reports documenting incidental uptake in the esophagus or GEJ and recommending upper endoscopy; and (2) had upper endoscopy within one year of the PET scan. Patients with known esophageal or GEJ cancer were excluded. 18F-FDG PET/CT images were assessed for uptake location, pattern (diffuse, segmental, or focal), eccentricity (circumferential or eccentric), maximal and mean standardized uptake values (SUVs), and CT findings (normal, wall thickening, or mass). Patients were categorized into benign conditions, Barrett's esophagus, and malignancies based on endoscopic and pathological diagnoses.

RESULTS: A total of 106 patients were included, comprising 82 cases of benign conditions, 11 Barrett's esophagus, and 13 malignancies. 18F-FDG PET/CT features were not significantly different between Barrett's esophagus and benign conditions. Compared with the Barrett's esophagus and benign conditions, malignant lesions showed a higher frequency of isolated mid-esophageal uptake (2.2% vs. 30.8%, P = 0.048), eccentric uptake (2.2% vs. 38.5%, P < 0.001), and wall thickening or mass on CT (15.1% vs. 92.4%, P < 0.001). Lesion SUVmax/liver SUVmean demonstrated excellent diagnostic performance in predicting malignancies (area under the curve 0.94). The presence of at least one of the following five features yielded 100% sensitivity, 65.6% specificity, and 28.9% positive predictive value for malignancies: focal uptake, eccentric uptake, isolated mid-esophageal uptake, lesion SUVmax/liver SUVmean ≥ 2.8, and wall thickening or mass on CT. The presence of at least two of these features increased specificity to 94.6% while maintaining 100% sensitivity.

CONCLUSION: Any of the five incidental 18F-FDG PET/CT imaging features in the esophagus or GEJ warrant endoscopy.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Cao Y, Kako B, Eighaei Sedeh A, et al. Incidental esophageal and gastroesophageal junction uptake on ¹8F-FDG PET/CT: when is upper endoscopy warranted? Abdom Radiol (NY). 2025. PMID: 41134365. doi:10.1007/s00261-025-05257-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。