文献速递腹部外周血管介入MRCTDSA

平衡稳态自由进动成像在球囊闭塞逆行经静脉栓塞术前评估门体分流道中的价值

Usefulness of balanced steady-state free precession for portosystemic shunts prior to balloon-occluded retrograde transvenous obliteration.
PubMed 文献 · Clin Radiol · 2025-09-11

本研究在球囊闭塞逆行经静脉栓塞术前用平衡稳态自由进动(bSSFP)成像显示门体分流道,并与对比增强CT(CECT)比较。22例中bSSFP仅10例评为良好显示、9例显示不佳、3例未显示,而CECT全部良好显示(P<.001);bSSFP显示侧支引流静脉13条,CECT显示20条。作者认为bSSFP是显示门体分流道的潜在替代方法,但效果不及CECT。

要点

  • bSSFP对门体分流道的良好显示率低于CECT(22例中10例 vs 全部),差异有统计学意义(P<.001)。
  • 分流道周围组织信号强度和运动伪影是bSSFP良好显示的影响因素(单因素均P<.05)。
  • bSSFP显示侧支引流静脉13条,少于球囊闭塞逆行经静脉造影显示的30条中的CECT所见20条。

核心结论

  • bSSFP成像可作为显示门体分流道的潜在替代方法,但效果不及对比增强CT。

研究设计与样本

  • 回顾性纳入2017年3月至2021年9月行球囊闭塞逆行经静脉栓塞术前同时具备bSSFP与CECT门体分流道成像的患者22例,以CECT为对照,按自流入静脉至流出静脉全程可追踪与否将图像质量分为良好显示、显示不佳、未显示三级。

关键影像表现/征象

  • bSSFP图像上22例中10例良好显示、9例显示不佳、3例未显示,CECT全部22例良好显示。
  • 两种检查方法良好显示例数差异有统计学意义(P<.001)。
  • 球囊闭塞逆行经静脉造影共显示侧支引流静脉30条,bSSFP显示其中13条,CECT显示其中20条。

诊断标准与关键数值

  • 图像质量分级标准:自流入静脉至流出静脉的整个门体分流道路径可追踪为良好显示,否则为显示不佳或未显示。
  • 单因素分析显示分流道周围组织信号强度与运动伪影是bSSFP良好显示的影响因素(均P<.05)。
  • 多因素分析显示分流道周围组织信号强度是bSSFP良好显示的影响因素(P<.001)。

临床应用与阅片要点

  • bSSFP可用于术前显示门体分流道,但良好显示率低于CECT,阅片时需注意其显示不佳或未显示的病例。
  • 分流道周围组织信号强度与运动伪影可能影响bSSFP对门体分流道的显示质量。
  • bSSFP对侧支引流静脉的显示少于CECT(13条 vs 20条),评估侧支引流静脉时以CECT为准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: This study visualised portosystemic shunts (PSSs), referring to gastrorenal or splenorenal shunts, on balanced steady-state free precession (bSSFP) imaging and assessed its accuracy compared with contrast-enhanced computed tomography (CECT).

MATERIALS AND METHODS: Patients with bSSFP and CECT imaging of a PSS prior to balloon-occluded retrograde transvenous obliteration from March 2017 to September 2021 were included. The quality of both images was graded based on whether the entire PSS pathway from the afferent vein to the efferent vein was traceable as "well-visualised," "poorly visualised," or "not visualised." Factors contributing to well-visualised on bSSFP images were investigated, including sex, age, height, weight, diagnosis (gastric varices or hepatic encephalopathy), type of PSS, maximum short-axis diameter of the PSS, signal intensity of the surrounding tissue around the PSS, and motion artifacts. Visualisation of collateral drainage veins of the PSS was also evaluated.

RESULTS: Ten of 22 cases were graded well-visualised, 9 poorly visualised, and 3 not visualised on bSSFP images, whereas all cases were graded well-visualised on CECT. There was a significant difference between the two imaging modalities for well-visualised images (P<.001). Univariate analyses identified signal intensity of the surrounding tissue around the PSS and motion artifacts as factors contributing to well-visualised on bSSFP images (both P<.05). Multivariate analysis also showed that the former factor contributed to well-visualised images (P<.001). Of 30 collateral veins visualised on balloon-occluded retrograde transvenous venography , 13 were seen on bSSFP and 20 on CECT.

CONCLUSION: Though bSSFP imaging is a potential alternative for visualising PSS, it is less effective than contrast-enhanced computed tomography.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Matsushita K, Kageyama K, Yamamoto A, et al. Usefulness of balanced steady-state free precession for portosystemic shunts prior to balloon-occluded retrograde transvenous obliteration. Clin Radiol. 2025. PMID: 41067109. doi:10.1016/j.crad.2025.107083

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。