低剂量双能CT联合深度学习图像重建用于肝转移瘤的检出与定性
前瞻性纳入80例已知或疑似肝转移瘤受试者,分别接受标准剂量单能CT(40例)或低剂量双能CT(40例,40与70 keV虚拟单能图像联合高强度深度学习重建)。低剂量双能CT在辐射剂量降低45%的条件下图像质量更优或相当,病灶检出率无显著差异,光谱参数鉴别转移瘤与囊肿的AUC达0.977至0.990。
要点
- 低剂量双能CT联合深度学习重建可在辐射剂量降低45%时保持肝转移瘤检出率与标准剂量单能CT相当。
- 40与70 keV虚拟单能图像联合高强度深度学习重建的CNR、SNR及肝脏-病灶对比噪声比优于标准剂量单能CT。
- 光谱曲线斜率、碘浓度、归一化碘浓度及有效原子序数鉴别肝转移瘤与囊肿的AUC分别为0.977、0.990、0.982、0.980。
核心结论
- 深度学习图像重建可有效降低双能CT 40与70 keV虚拟单能图像的噪声并提升图像质量,在辐射剂量降低45%的条件下不损害肝转移瘤诊断;双能CT光谱参数可准确鉴别转移瘤与囊肿。
研究设计与样本
- 前瞻性研究,2023年6月至2025年1月纳入80例已知或疑似肝转移瘤受试者,标准剂量单能CT组40例采用120 kVp图像联合ASIR-V 40%,低剂量双能CT组40例采用40与70 keV虚拟单能图像联合高强度深度学习重建。
诊断标准与关键数值
- 光谱曲线斜率、碘浓度、归一化碘浓度及有效原子序数鉴别肝转移瘤与囊肿的AUC分别为0.977、0.990、0.982、0.980。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare image quality and diagnostic performance of reduced-dose dual-energy CT (DECT) with deep learning image reconstruction (DLIR) versus standard-dose single-energy CT (SECT) with adaptive statistical iterative reconstruction-Veo (ASIR-V) for detecting liver metastases, and to evaluate the efficacy of differentiating metastases from cysts using DECT spectral parameters.
METHODS: Eighty participants with known or suspected liver metastases from June 2023 to January 2025 were prospectively enrolled and underwent contrast-enhanced liver CT with either standard-dose SECT (n = 40, 120-kVp images, ASIR‑V 40 %) or reduced-dose DECT (n = 40, 40- and 70-keV virtual monoenergetic images [VMIs], high-intensity DLIR [DH]). The objective image noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), liver-to-lesion contrast-to-noise ratio (LLR), subjective image quality, lesion conspicuity, and detection rate were assessed. The diagnostic performance of spectral parameters for differentiating metastases from cysts was evaluated using receiver operating characteristic (ROC) curves.
RESULTS: DH significantly reduced image noise of DECT scans in reduced radiation dose conditions. With a 45 % dose reduction, the 40- and 70-keV VMIs with DH showed higher CNR, SNR, and LLR, better image quality and similar lesion detection rates and better or comparable lesion conspicuity compared with AR40 120-kVp images (P > 0.05). The use of the spectral curve slope, iodine concentration, normalized iodine concentration, and effective atomic number yielded the area under the curve (AUC) values of 0.977, 0.990, 0.982, and 0.980 for differentiating metastases from cysts, respectively.
CONCLUSION: DLIR effectively reduces image noise and improves image quality of the 40- and 70-keV VMIs in DECT, achieving a 45% radiation dose reduction without compromising metastases diagnosis. DECT spectral parameters enable accurate differentiation of metastases from cysts.
引用
- Li Y, Li L, Liu Y, et al. Reduced-dose dual-energy CT with deep learning image reconstruction for detection and characterization of liver metastases. Eur J Radiol. 2025. PMID: 41033013. doi:10.1016/j.ejrad.2025.112452
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。