文献速递妇产影像儿科影像心血管US

18至35周胎儿超声心动图脉冲波多普勒与结构测量的参考范围及Z评分计算器:一项横断面研究

Reference Ranges and Z-Score Calculators for Pulsed-Wave Doppler and Structural Measurements in Fetal Echocardiography Between 18 and 35 Weeks of Gestation: A Cross-Sectional Study.
PubMed 文献 · J Ultrasound Med · 2025-10-18

该研究基于中国3家三级医疗中心22,357例18至35周心脏结构和功能正常的胎儿超声心动图检查,回顾性分析43项心血管参数(13项结构测量和30项脉冲波多普勒测量),采用分数多项式回归建立与孕龄相关的参考范围和Z评分模型,38项参数模型拟合满意,5项脉冲波多普勒参数因正态性或回归拟合不佳被排除,并开发了在线Z评分计算器。

要点

  • 提供了18至35周汉族胎儿43项心血管参数中38项的孕龄特异性参考范围和Z评分。
  • 13项结构测量和25项脉冲波多普勒测量模型拟合满意,5项脉冲波多普勒参数被排除。
  • 开发了在线Z评分计算器(http://www.anzscore.com)以促进临床应用。

核心结论

  • 该研究基于大量汉族中国人群提供了胎儿超声心动图参数的综合参考范围和Z评分模型,为亚洲人群产前心脏评估提供了可靠基础,并支持开发人群特异性诊断工具。

研究设计与样本

  • 回顾性横断面研究,纳入中国3家三级医疗中心18至35周、经标准化超声心动图方案确认心脏结构和功能正常的胎儿超声心动图检查22,357例,评估43项心血管参数(13项结构测量和30项脉冲波多普勒测量),采用分数多项式回归建模参数与孕龄的关系,并使用预测均值和孕龄依赖的标准差建立Z评分模型。

诊断标准与关键数值

  • 38项参数(13项结构测量和25项脉冲波多普勒测量)模型拟合满意;5项脉冲波多普勒参数因正态性差或回归拟合不足被排除;最终模型与孕龄显示出强的统计学一致性,无需数学变换;为每个参数生成了孕龄特异性参考范围和Z评分,并提供完整的百分位表。

临床应用与阅片要点

  • 研究结果可用于产前心脏评估的参考,并支持开发人群特异性诊断工具;在线Z评分计算器(http://www.anzscore.com)可促进临床应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To establish gestational-age-specific reference ranges and Z-score models for fetal echocardiographic measurements using a large multicenter dataset from China.

METHODS: We retrospectively analyzed 22,357 fetal echocardiographic examinations conducted between 18 and 35 weeks of gestation across 3 tertiary medical centers in China. All fetuses had structurally and functionally normal hearts, confirmed by standardized echocardiographic protocols. A total of 43 cardiovascular parameters were assessed, including 13 structural and 30 pulsed-wave Doppler (PWD) measurements. Fractional polynomial regression was used to model the relationship between each parameter and gestational age (GA). Z-score models were developed using predicted means and GA-dependent standard deviations. Model performance was evaluated using residual analysis, quantile-quantile (QQ) plots, and goodness-of-fit statistics.

RESULTS: Thirty-eight parameters (13 structural and 25 PWD) demonstrated satisfactory model fit. Five PWD parameters were excluded due to poor normality or inadequate regression fit. The final models showed strong statistical agreement with GA, and no mathematical transformations were necessary. Gestational-age-specific reference ranges and Z-scores were generated for each parameter, with full percentile tables provided. An online Z-score calculator (http://www.anzscore.com) was developed to facilitate clinical application.

CONCLUSIONS: This study provides comprehensive reference ranges and Z-score models for fetal echocardiographic parameters based on a large Han Chinese population. These results offer a reliable foundation for prenatal cardiac assessment in Asian populations and support the development of population-specific diagnostic tools.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Peng N, Weng Z, Xie J, et al. Reference Ranges and Z-Score Calculators for Pulsed-Wave Doppler and Structural Measurements in Fetal Echocardiography Between 18 and 35 Weeks of Gestation: A Cross-Sectional Study. J Ultrasound Med. 2025. PMID: 41108647. doi:10.1002/jum.70089

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。