文献速递心血管CT

基于深度学习的人工智能辅助对冠状动脉CT血管成像判读中阅片者一致性的影响

Impact of Deep Learning-based Artificial Intelligence Assistance on Reader Agreement in Coronary CT Angiography Interpretation.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

这项回顾性研究纳入623例患者共11214个冠状动脉节段的CCTA检查,评估全自动多任务深度学习算法对CAD-RADS分级阅片者一致性的影响。AI辅助下,阅片者1与阅片者2的一致性ρ=0.899-0.949(P<.001),与阅片者3的一致性ρ=0.889-0.938(P<.001);在阅片者1与AI不一致的亚组中,手动判读时阅片者1与阅片者2一致性ρ=0.688,双方均使用AI辅助后升至ρ=0.975(P<.001)。结论认为AI辅助判读显著改善了CCTA的CAD-RADS分类阅片者一致性。

要点

  • AI辅助使阅片者1与阅片者2的CAD-RADS一致性达ρ=0.899-0.949(P<.001)。
  • AI辅助使阅片者1与阅片者3的一致性达ρ=0.889-0.938(P<.001)。
  • 阅片者1与AI不一致亚组中,双方用AI后一致性由ρ=0.688升至ρ=0.975(P<.001)。

核心结论

  • 使用深度学习算法的AI辅助判读显著改善了CCTA中CAD-RADS分类的阅片者间一致性。

研究设计与样本

  • 回顾性研究纳入623例临床指征CCTA检查,来自2010年1月至2019年12月多家厂商CT系统,共分析11214个冠状动脉节段。
  • 专家阅片者1对所有CCTA手动及AI辅助判读,在病变、冠状动脉节段和患者水平采用CAD-RADS分级。
  • AI算法检测、量化并分类冠状动脉病变;阅片者2分析随机选取的274例亚组评估阅片者间一致性。
  • 放射科报告(阅片者3)的CAD-RADS评分可用于362例患者;30例不一致亚组中阅片者2也用AI辅助判读。
  • 采用Spearman相关评估判读间一致性,逻辑回归和混合模型评估AI辅助判读对CAD-RADS分类的影响。

诊断标准与关键数值

  • 623例患者中295例(47.9%)无CAD(CAD-RADS 0),213例(33.6%)冠状动脉阻塞低风险(CAD-RADS<3),115例(18.5%)阻塞性疾病高风险(CAD-RADS≥3)。
  • AI辅助下阅片者1与阅片者2一致性ρ=0.899-0.949(P<.001),与阅片者3一致性ρ=0.889-0.938(P<.001)。
  • 阅片者1与AI不一致亚组中,手动判读时阅片者1与阅片者2一致性ρ=0.688,双方均用AI辅助判读后升至ρ=0.975(P<.001)。

临床应用与阅片要点

  • AI辅助判读可提高CCTA的CAD-RADS分类在病变、节段和患者水平的阅片者间一致性。
  • 在阅片者与AI判读不一致的病例中,双方均使用AI辅助可大幅提高一致性(ρ=0.688升至ρ=0.975)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the impact of a fully automated, multitask deep learning (DL) algorithm on interreader agreement of coronary artery disease (CAD) detection and stenosis classification using coronary CT angiography (CCTA). Materials and Methods This retrospective study included CCTA examinations (n = 623 patients) performed for clinical indications on CT systems from multiple vendors between January 2010 and December 2019. An expert reader (reader 1) analyzed all CCTA scans manually and with artificial intelligence (AI)-assisted reading at the lesion, coronary segment, and patient levels using the CAD Reporting and Data System (CAD-RADS). The AI algorithm detected, quantified, and classified coronary lesions. Interreader agreement was evaluated using a second expert reader (reader 2), who analyzed a randomly selected subset of 274 patients. CAD-RADS scores from radiologist reports (reader 3) were available for 362 patients. In a subgroup of 30 patients with disagreements, R2 also interpreted the cases using AI assistance. Agreement between readings, with and without AI, was assessed using Spearman correlation, and logistic regression and mixed models evaluated the impact of AI-assisted reading on CAD-RADS classification. Results The final study sample included 11 214 coronary segments analyzed from 623 patients (mean age ± SD, 54.8 years ± 15.7; 341 male). Of these patients, 295 (47.9%) had no CAD (CAD-RADS 0), 213 (33.6%) had low risk of coronary obstruction (CAD-RADS < 3), and 115 (18.5%) had high risk of obstructive disease (CAD-RADS ≥ 3). With AI assistance, reader 1 demonstrated improved agreement with reader 2 (ρ = 0.899-0.949; P < .001) and reader 3 (ρ = 0.889-0.938; P < .001). In the subgroup with reader 1-AI disagreement, agreement between reader 1 and reader 2 was low with manual readings (ρ = 0.688) but increased substantially when both readers used AI-assisted reading (ρ = 0.975; P < .001). Conclusion AI-assisted reading using a DL algorithm significantly improved interreader agreement for CAD-RADS classification at CCTA. Keywords: Applications - CT, CT-Coronary Angiography, Deep Learning Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Farì R, van Assen M, Quintana R, et al. Impact of Deep Learning-based Artificial Intelligence Assistance on Reader Agreement in Coronary CT Angiography Interpretation. Radiol Cardiothorac Imaging. 2025. PMID: 41065550. doi:10.1148/ryct.240563

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。