文献速递胸部儿科影像CT

儿童光子计数胸部CT可在保持图像质量的同时降低碘对比剂剂量

Pediatric photon-counting chest CT enables iodinated contrast dose reduction with preserved image quality.
PubMed 文献 · Pediatr Radiol · 2025-10-11

这项回顾性观察研究纳入60例儿童增强胸部CT,比较光子计数探测器(PCD)CT在1.5 mL/kg碘对比剂剂量下与能量积分探测器(EID)CT在1.5 mL/kg和2.0 mL/kg剂量下的图像质量。结果显示PCD CT在1.5 mL/kg时左心室腔SNR和CNR高于EID CT同等剂量,主观整体对比增强也优于EID CT同等剂量,支持在保持图像质量的同时降低碘对比剂剂量。

要点

  • 儿童胸部增强CT采用光子计数探测器可在1.5 mL/kg碘对比剂剂量下保持图像质量。
  • PCD CT 1.5 mL/kg较EID CT 1.5 mL/kg左心室腔SNR更高(21.6 vs 16.2)。
  • 主观整体对比增强PCD CT 1.5 mL/kg优于EID CT 1.5 mL/kg(中位评分1 vs 2)。

核心结论

  • 儿童胸部CT使用光子计数探测器技术可在保持图像质量的同时降低碘对比剂剂量,优于常规EID CT标准对比剂剂量。

研究设计与样本

  • 回顾性观察研究,纳入60例儿童增强胸部CT,分为三组各20例:PCD CT 1.5 mL/kg、EID CT 1.5 mL/kg、EID CT 2.0 mL/kg。

诊断标准与关键数值

  • PCD CT 1.5 mL/kg较EID CT 1.5 mL/kg左心室腔SNR 21.6(IQR 16.3-25.1)vs 16.2(IQR 12.3-19.3),P=0.05;CNR 16.0(IQR 11.3-19.5)vs 10.3(IQR 8.8-13.7),P=0.05。

临床应用与阅片要点

  • 儿童胸部增强CT可考虑采用光子计数探测器技术在1.5 mL/kg碘对比剂剂量下扫描,以降低对比剂剂量并保持图像质量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Photon-counting detector (PCD) CT allows for reduced intravenous iodinated contrast dosing with preserved or improved image quality across anatomical regions as compared to conventional energy-integrating detector (EID) CT in adults. However, there is limited evidence to support this in pediatric CT, particularly for pediatric chest CT.

OBJECTIVE: To compare image quality of photon-counting detector (PCD) chest CT with energy-integrating detector (EID) CT at varying iodinated contrast doses in pediatric patients.

METHODS AND MATERIALS: This retrospective observational study included 60 contrast-enhanced chest CT studies in pediatric patients. The cohort included three groups: 20 PCD CT scans with a 1.5 mL/kg weight-based iodinated contrast dose, 20 EID CT scans with a 1.5 mL/kg dose, and 20 EID CT scans with a 2.0 mL/kg dose. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were assessed through region-of-interest measurement of Hounsfield units (HU) and standard deviation (SD). Assessed locations were the lung parenchyma, thoracic aorta, main pulmonary artery, left ventricle cavity, subcutaneous tissue, and pectoralis muscle. Blinded review by three pediatric radiologists assessed overall contrast enhancement, soft tissue delineation, and streak artifact from dense contrast using 5-point Likert scales (1 - excellent to 5 - non-diagnostic). Group comparisons were analyzed using Wilcoxon signed-rank, Chi-square, and Kruskal-Wallis tests.

RESULTS: Twenty patients were included for each group (60 patients total). Compared to equivalent-contrast dose EID CT at 1.5 mL/kg, PCD CT showed higher left ventricle cavity SNR (21.6 [IQR 16.3-25.1] vs 16.2 [IQR 12.3-19.3], P = 0.05) and CNR (16.0 [IQR 11.3-19.5] vs 10.3 [8.8-13.7] P = 0.05), and lower image noise in pectoralis muscle (P = 0.04) and subcutaneous fat (P < 0.01). Furthermore, objective image quality on PCD CT demonstrated improvements in lung parenchyma noise, SNR, and CNR, as well as subcutaneous fat SNR and CNR (all P < 0.01) compared with both equivalent (1.5 mL/kg) and standard (2.0 mL/kg) contrast dosing in EID CT. No significant differences between PCD CT and EID CT were observed with other objective measures of image quality. Subjective assessments favored PCD CT for overall contrast enhancement to EID CT at equivalent (1.5 mL/kg) contrast dosing (median 1, IQR 1-1 vs median 2, IQR 1-5, P = 0.02) and soft tissue delineation compared with EID CT with higher (2.0 mL/kg) contrast dosing (median 1, IQR 1-2 vs median 2, IQR 1-2, P = 0.05).

CONCLUSION: Pediatric chest CT using photon-counting detector technology enables iodinated contrast dose reduction while preserving image quality compared with conventional EID CT at standard contrast doses.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Daniels AA, Pinkney LP, Strubel NA, et al. Pediatric photon-counting chest CT enables iodinated contrast dose reduction with preserved image quality. Pediatr Radiol. 2025. PMID: 41073750. doi:10.1007/s00247-025-06394-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。