文献速递头颈神经CTMR

改良Node-RADS用于诊断鼻咽癌腮腺淋巴结转移

Modifying node-RADS in diagnosing parotid lymph node metastasis of nasopharyngeal carcinoma.
PubMed 文献 · Eur J Radiol · 2025-09-25

本研究回顾性纳入两家机构166例和60例伴腮腺淋巴结的鼻咽癌患者,以病灶面积和短径两个最优变量改良Node-RADS,建立la-mNode-RADS和sa-mNode-RADS;内部队列中两者AUC均高于传统Node-RADS(0.912或0.911 vs. 0.870,均p<0.05),二分类后敏感度更高而特异度相似,外部队列验证短径7.5 mm阈值表现更优。

要点

  • 腮腺淋巴结转移诊断中,病灶面积AUC=0.877(cutoff=60.69 mm2),短径AUC=0.869(cutoff=7.5 mm)。
  • la-mNode-RADS与sa-mNode-RADS的AUC分别为0.912和0.911,均高于传统Node-RADS的0.870。
  • 二分类(评分1-2 vs. 3-5)时敏感度94.8% vs. 92.7% vs. 76.0% vs. 77.1%,特异度相似。

核心结论

  • 作者认为,简便易用的sa-mNode-RADS在检测鼻咽癌腮腺淋巴结转移方面诊断性能优于传统Node-RADS。

研究设计与样本

  • 回顾性研究,纳入两家机构166例和60例伴腮腺淋巴结的鼻咽癌患者,比较初始影像特征诊断转移性腮腺淋巴结的AUC,以病灶面积和短径分别改良Node-RADS建立la-mNode-RADS和sa-mNode-RADS。

诊断标准与关键数值

  • 内部队列中病灶面积AUC=0.877(cutoff=60.69 mm2),短径AUC=0.869(cutoff=7.5 mm);la-mNode-RADS与sa-mNode-RADS的AUC分别为0.912和0.911,传统Node-RADS为0.870(均p<0.05)。

临床应用与阅片要点

  • 二分类(评分1-2 vs. 3-5)时la-mNode-RADS、sa-mNode-RADS、Node-RADS和短径的敏感度分别为94.8%、92.7%、76.0%和77.1%(均p<0.05),特异度分别为78.7%、79.8%、84.3%和86.5%(均p>0.05),准确度分别为87.0%、86.5%、80.0%(均p<0.05)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to establish a modified Node Reporting and Data System (mNode-RADS) for differentiating metastatic from benign parotid lymph nodes (PLNs) in nasopharyngeal carcinoma (NPC).

MATERIALS AND METHODS: 166 and 60 NPC patients with PLN from two institutions were retrospectively reviewed. The diagnostic performance of initial imaging characteristics for metastatic PLN (PLNM) was compared using the area under the curve (AUC). Two top-performing variables, lesion area and short axis, were used to modify Node-RADS (la-mNode-RADS and sa-mNoder-RADS, respectively). The AUC, sensitivity, specificity, and accuracy were compared among short axis, conventional and modified Node-RADS criteria.

RESULTS: In the internal cohort, the lesion area showed the highest diagnostic performance (AUC = 0.877; cutoff = 60.69 mm2), followed by the short axis (AUC = 0.869; cutoff = 7.5 mm). Both la-mNode-RADS and sa-mNode-RADS achieved higher AUCs than Node-RADS (0.912 or 0.911 vs. 0.870; all p < 0.05). Dichotomized la-mNode-RADS and sa-mNode-RADS (scores 1-2 vs. 3-5) showed greater sensitivity than Node-RADS or short axis (94.8 % vs. 92.7 % vs. 76.0 % vs. 77.1 %; all p < 0.05), with similar specificity (78.7 % vs. 79.8 % vs. 84.3 % vs. 86.5 %; all p > 0.05). Both la-mNode-RADS and sa-mNode-RADS had higher accuracy than Node-RADS (87.0 % or 86.5 % vs. 80.0 %; all p < 0.05). No significant differences were observed between la-mNode-RADS and sa-mNode-RADS. The superior diagnostic performance of short-axis threshold of 7.5 mm and its corresponding mNode-RADS was also confirmed in external cohort.

CONCLUSIONS: The user-friendly sa-mNode-RADS shows superior diagnostic performance over traditional Node-RADS in detecting PLNM in NPC.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. He D, Liang H, Deng Y, et al. Modifying node-RADS in diagnosing parotid lymph node metastasis of nasopharyngeal carcinoma. Eur J Radiol. 2025. PMID: 41027214. doi:10.1016/j.ejrad.2025.112451

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。