文献速递神经介入CT

非增强CT与CT灌注预测前循环大血管闭塞卒中取栓术后结局的比较

Non-Contrast CT versus CT perfusion for predicting post-thrombectomy outcomes in anterior circulation large vessel occlusion stroke.
PubMed 文献 · Neuroradiology · 2025-10-28

双中心回顾性队列纳入216例前循环大血管闭塞卒中取栓患者,比较非增强CT-临床模型与CT灌注-临床模型预测90天功能独立(mRS 0-2)的能力。非增强CT-临床模型AUC 0.819,CT灌注-临床模型AUC 0.834,ΔAUC=0.015,P=0.964,差异无统计学意义。结论认为在延长时间窗内两模型预测预后能力相当。

要点

  • 非增强CT-临床模型纳入ASPECTS、基线NIHSS和糖尿病状态,AUC 0.819。
  • CT灌注-临床模型纳入缺血核心体积、基线NIHSS和糖尿病状态,AUC 0.834。
  • 两模型AUC差异ΔAUC=0.015(P=0.964),准确度、敏感度、特异度均相当。

核心结论

  • 在延长时间窗前循环大血管闭塞卒中取栓患者中,非增强CT-临床模型预测90天功能独立的能力与CT灌注-临床模型相当。

研究设计与样本

  • 双中心回顾性队列研究,纳入2021年5月至2024年3月连续216例接受血管内取栓的前循环大血管闭塞急性缺血性卒中患者。
  • 以90天功能独立(改良Rankin量表0-2分)为主要终点,采用5折交叉验证计算ROC曲线,DeLong检验比较AUC差异。

诊断标准与关键数值

  • 非增强CT-临床模型纳入ASPECTS、基线NIHSS和糖尿病状态,AUC为0.819。
  • CT灌注-临床模型纳入缺血核心体积、基线NIHSS和糖尿病状态,AUC为0.834。
  • 两模型AUC差异无统计学意义(ΔAUC=0.015,P=0.964)。
  • 非增强CT-临床模型与CT灌注-临床模型的准确度分别为74.0%与75.8%,敏感度分别为80.5%与82.1%,特异度分别为65.7%与67.7%。

临床应用与阅片要点

  • 原文结论认为非增强CT-临床模型在延长时间窗前循环大血管闭塞卒中取栓预后预测方面与CT灌注-临床模型能力相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: While CT perfusion (CTP) is the current standard for endovascular thrombectomy (EVT) selection in extended time windows with acute ischemic stroke with large vessel occlusion (LVO-AIS), the added prognostic value of CTP over non-contrast CT (NCCT)-based models remains debated, particularly when combined with clinical variables.

METHODS: In this dual-center retrospective cohort study, we analyzed 216 consecutive anterior circulation LVO-AIS patients undergoing EVT between May 2021 and March 2024. Univariate and multivariate analysis were performed on both NCCT-derived and CTP-derived imaging parameters alongside clinical variables, with 90-day functional independence (modified Rankin Scale [mRS] 0-2) as primary endpoint. The ROC curves of the two models were computed using 5-fold cross-validation, and differences in the area under the curve (AUC) were evaluated using DeLong's test.

RESULTS: Functional independence (mRS 0-2) was achieved in 42.6% (92/216) of the patients. The NCCT-clinical model incorporated ASPECTS, baseline NIHSS and diabetes status, and the CTP-clinical model incorporated ischemic core volume, baseline NIHSS and diabetes status. The NCCT-clinical model demonstrated AUC of 0.819 and the CTP-clinical model 0.834. The difference of AUC showed no statistical significance between NCCT-clinical model and the CTP-clinical model (ΔAUC = 0.015, P = 0.964). The NCCT-clinic model demonstrated comparable performance to CTP-clinic model, including accuracy (74.0% vs. 75.8%), sensitivity (80.5% vs. 82.1%) and specificity (65.7% vs. 67.7%).

CONCLUSION: The NCCT-clinical model achieved comparable ability to predict prognosis compared to the CTP-clinical model in extended time windows with LVO-AIS.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Ma Y, Liu Y, Tang M, et al. Non-Contrast CT versus CT perfusion for predicting post-thrombectomy outcomes in anterior circulation large vessel occlusion stroke. Neuroradiology. 2025. PMID: 41148290. doi:10.1007/s00234-025-03800-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。