文献速递神经介入DSA

血流导向装置与弹簧圈栓塞联合或不联合支架治疗未破裂宽颈颅内动脉瘤的随机对照比较

Flow Diversion versus Coiling with or without Stenting for Unruptured Wide-Neck Intracranial Aneurysms: A Randomized Comparison.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-04-02

EVIDENCE试验在7家法国大学医院将91例7-20mm未破裂宽颈颅内动脉瘤患者随机分配至血流导向装置组或弹簧圈栓塞(联合或不联合支架)组,主要复合疗效终点为治疗失败;可评估的86例中血流导向装置组8/43(18.6%)vs 弹簧圈组10/43(23.3%),RR=0.80(95%CI 0.35-1.83,P=.60),血流导向装置不优于弹簧圈栓塞。

要点

  • 在多数为<10mm未破裂宽颈眼动脉段动脉瘤患者中,血流导向装置主要疗效终点不优于弹簧圈栓塞联合或不联合支架。
  • 主要终点治疗失败率血流导向装置组18.6%(95%CI 9.7%-32.6%)vs 弹簧圈组23.3%(95%CI 13.1%-37.7%),RR=0.80(95%CI 0.35-1.83,P=.60)。
  • 两组严重不良事件相似。

核心结论

  • 对于多数为<10mm未破裂宽颈眼动脉段动脉瘤患者,血流导向装置不优于弹簧圈栓塞联合或不联合支架。

研究设计与样本

  • 研究者发起的随机(1:1)试验,在7家法国大学医院开展;91例入组,4例撤回知情同意,87例纳入分析(血流导向装置组43例,对照组44例);纳入标准为7-20mm硬膜内未破裂颅内动脉瘤、瘤颈4-10mm且「瘤顶/瘤颈」比值≥1;主要分析为意向性治疗分析。

诊断标准与关键数值

  • 主要复合疗效终点「治疗失败」定义:初始治疗动脉瘤失败、随访期间动脉瘤破裂或再治疗、死亡或依赖(mRS>2)、或12个月时由独立核心实验室判定的血管造影残留动脉瘤;可评估86例中,血流导向装置组8/43(18.6%,95%CI 9.7%-32.6%)vs 弹簧圈组10/43(23.3%,95%CI 13.1%-37.7%),RR=0.80(95%CI 0.35-1.83,P=.60)。

临床应用与阅片要点

  • 对于多数为<10mm未破裂宽颈眼动脉段动脉瘤患者,血流导向装置与弹簧圈栓塞联合或不联合支架的严重不良事件相似,主要疗效终点无统计学显著差异。

局限性

  • 因入组缓慢修订主要假设,原假设血流导向装置将治疗失败率从35%降至10%,需90例;4例(每组2例)撤回知情同意,87例纳入分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: There are few randomized trials comparing coiling (with or without stent placement) and flow diversion (FD) for the treatment of wide-neck unruptured intracranial aneurysms.

MATERIALS AND METHODS: EVIDENCE was an investigator-led randomized (1:1) trial conducted in 7 French university hospitals. Patients with 7 to 20-mm intradural unruptured intracranial aneurysms with a 4- to 10-mm neck and a "dome/neck" ratio of ≥1 were randomly allocated to coiling with or without adjunctive stent placement or FD alone. The composite primary efficacy outcome was "treatment failure," defined as initial failure to treat the aneurysm; aneurysm rupture or retreatment during follow-up; death or dependency (mRS> 2); or an angiographic residual aneurysm adjudicated by an independent core laboratory at 12 months. The primary hypothesis (revised for slow accrual) was that FD would decrease treatment failures from 35% to 10%, requiring 90 patients. Primary analyses were intent to treat.

RESULTS: Among the 91 enrolled patients, four (two in each group) withdrew consent; 87 patients were included in the analysis: 43 in the FD group and 44 in the control group. Most patients had <10 mm (57/87; 65.5%) asymptomatic ophthalmic aneurysms (75/87, 86.2%). A poor primary outcome, ascertainable in 86 patients, was reached in 8/43 patients with FD (18.6%; 95% CI, 9.7%-32.6%) compared with 10/43 coiling patients (23.3%; 95 CI, 13.1%-37.7%) (RR = 0.80; 95% CI, 0.35-1.83; P = .60). Serious adverse events were similar.

CONCLUSIONS: For patients with mostly unruptured, wide-neck ophthalmic aneurysms of <10 mm, FD was not superior to coiling with or without stent placement.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Boisseau W, Combaz X, Levrier O, et al. Flow Diversion versus Coiling with or without Stenting for Unruptured Wide-Neck Intracranial Aneurysms: A Randomized Comparison. AJNR Am J Neuroradiol. 2026. PMID: 41093742. doi:10.3174/ajnr.A9044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。