评估简化MRI方案在肺癌初始分期中筛查脑转移的价值
本研究为单中心回顾性研究,纳入54例肺癌初始分期患者,比较仅含3D FLAIR和增强3D T1w-SE的简化方案与标准方案的诊断效能。简化方案检测脑转移的敏感度和特异度均超过90%,患者水平和病灶水平诊断准确性与标准方案相当。简化方案可能缩短检查时间并改善MRI可及性。
要点
- 简化方案(3D FLAIR+增强3D T1w-SE)筛查脑转移的敏感度和特异度均超过90%。
- 患者水平和病灶水平诊断效能与标准方案相当,不受阅片者经验显著影响。
- 简化方案未检出3例缺血事件和1例动脉瘤等主要次要发现。
核心结论
- 仅含3D FLAIR和增强T1w-SE的简化脑MRI方案对肺癌患者脑转移筛查的诊断准确性与标准方案相当,缩短检查时间可能改善MRI可及性。
研究设计与样本
- 单中心回顾性研究,纳入54例肺癌初始分期患者,由4名放射科医生分别阅读简化方案(3D FLAIR和3D T1w-SE)与标准方案(DWI、T2*、3D FLAIR、平扫T1、增强3D T1w-GRE和增强3D T1w-SE),以患者和病灶为单位评估诊断效能。
诊断标准与关键数值
- 简化方案检测脑转移的敏感度和特异度在患者水平和病灶水平均超过90%;35%的患者有脑转移;简化方案检出22例转移患者,假阳性3例。
临床应用与阅片要点
- 简化方案可用于肺癌初始分期脑转移筛查,但需注意可能遗漏缺血事件和动脉瘤等次要发现。
局限性
- 单中心回顾性研究。
- 简化方案未检出3例缺血事件和1例动脉瘤,这些病变仅在长方案中检测到。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: In the routine clinical practice, only a few key sequences allow positive diagnosis of brain metastasis. The aim of our study was to investigate the diagnostic accuracy of a reduced protocol including only 2 sequences of interest for the detection of brain lesions in lung cancer.
MATERIALS AND METHODS: Fifty four patients undergoing MRI in the initial staging of lung cancer were included in this monocentric, retrospective study. Four radiologists reviewed the data from a short protocol with 2 sequences of interest (3D FLAIR and 3D T1w-SE sequences) and from the standard reference protocol (DWI, T2*, 3D FLAIR, non-enhanced T1, post-contrast 3D T1w-GRE and post-contrast 3D T1w-SE sequences). Diagnostic performances were assessed on a per-patient and per-lesion basis.
RESULTS: In our population, 35% of patients had brain metastases. The short protocol detected 22 metastatic patients with 3 false positives. The analysis showed excellent diagnostic performance of the short protocol with more than 90% sensitivity and specificity, for both per-patient and per-lesion evaluations. Metastatic classification was not significantly influenced by the reviewer's experience. Seven major secondary findings were identified, including 3 ischemic events and 1 aneurysm that were only detected when the long protocol was used.
CONCLUSIONS: A short MRI brain protocol, including only 3D FLAIR and post-contrast T1w-SE sequences, demonstrated diagnostic accuracy equivalent to standard protocols for BM screening in lung cancer patients. The subsequent reduction in examination time can potentially improve access to MRI.
引用
- Vandendriessche C, Bouzerar R, Zemani A, et al. Evaluation of an abbreviated MRI protocol in the screening for brain metastases in the initial staging of lung cancer. Neuroradiology. 2025. PMID: 41137927. doi:10.1007/s00234-025-03817-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。