文献速递神经外周血管DSA

基于血管造影图像的颅内动脉粥样硬化性狭窄血流动力学评估:与支架内再狭窄的相关性

Hemodynamic Assessment of Intracranial Atherosclerotic Stenosis Using Angiographic Images: Correlation with In-Stent Restenosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-04-02

研究纳入54例接受脑血管造影的重度颅内动脉粥样硬化性狭窄患者,比较术前与术后即刻Angio-FF值,随访6个月中9例发生支架内再狭窄。术后即刻Angio-FF值在再狭窄组明显低于非再狭窄组(0.84 vs 0.94,P=0.007),预测再狭窄的AUC为0.785,截断值0.845。

要点

  • 术后即刻Angio-FF值在再狭窄组为0.84,低于非再狭窄组的0.94(P=0.007)。
  • 术后即刻Angio-FF预测支架内再狭窄的AUC为0.785(95%CI 0.647-0.923),截断值0.845。
  • 术前形态学与血流动力学指标在再狭窄组与非再狭窄组间无统计学显著差异。

核心结论

  • 术后即刻Angio-FF是支架内再狭窄的有效预测指标,可为评估颅内动脉粥样硬化性狭窄患者支架置入效果提供术中信息。

研究设计与样本

  • 研究纳入2019年1月至2022年9月期间54例接受脑血管造影的重度颅内动脉粥样硬化性狭窄患者,收集并比较术前与术后即刻Angio-FF值,随访6个月确认9例发生支架内再狭窄,采用ROC曲线分析术后即刻Angio-FF对支架内再狭窄的预测效能。

诊断标准与关键数值

  • 术后即刻Angio-FF预测支架内再狭窄的AUC为0.785(95%CI 0.647-0.923),截断值为0.845;再狭窄组术后即刻狭窄程度%为26(22-33),非再狭窄组为10(0-20),组间差异P<.001。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Cerebral hemodynamics hold profound clinical significance in the comprehensive management of intracranial atherosclerotic stenosis (ICAS). We have developed Angio-FF, a novel noninvasive fractional flow (FF) calculation technique derived from cerebral angiography, for evaluating hemodynamics in patients with ICAS. This study aims to evaluate the clinical applicability of Angio-FF in reflecting cerebral hemodynamics by assessing its correlation with in-stent restenosis (ISR) in patients with ICAS.

MATERIALS AND METHODS: A total of 54 patients with severe ICAS who had undergone cerebral angiography were recruited in the study between January 2019 and September 2022. For each patient, both preoperative and immediate postoperative Angio-FF values were collected and compared. During the 6-month follow-up, 9 patients were confirmed to have developed ISR. Receiver-operating characteristic curve (ROC) analysis was performed to evaluate the predictive efficacy of immediate postoperative Angio-FF value in differentiating between ISR and non-ISR.

RESULTS: No statistically significant disparities were detected in preoperative morphologic and hemodynamic between ISR and non-ISR groups. However, the immediately postoperative degree of stenosis% was significantly different between the ISR and non-ISR groups (26 [22-33] versus 10 [0-20]; P < .001). The postoperative Angio-FF value in the ISR group was markedly lower than that in the non-ISR group (0.84 [0.81-0.90] versus 0.94 [0.87-0.97]; P = .007). ROC analysis was performed to assess the predictive value of postoperative Angio-FF for ISR (area under the curve = 0.785; 95% CI, 0.647-0.923), with a cutoff value of 0.845.

CONCLUSIONS: This study reveals that immediately postoperative Angio-FF is an effective predictor of ISR, providing valuable intraoperative information for assessing the effectiveness of stent placement in patients with ICAS.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Wang L, Xiao X, Tan Y, et al. Hemodynamic Assessment of Intracranial Atherosclerotic Stenosis Using Angiographic Images: Correlation with In-Stent Restenosis. AJNR Am J Neuroradiol. 2026. PMID: 41115809. doi:10.3174/ajnr.A9050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。