使用商业深度学习算法在计算机断层扫描血管造影中回顾性检测漏诊的颅内动脉瘤
本研究回顾性收集单中心2020年2月18日至2022年7月31日连续成人头部CTA,用NLP分类报告、CNN分析图像,不一致病例由三名神经放射学家多数投票确定参考标准。算法标记34例疑似漏诊动脉瘤,67%(23/34)经至少两名神经放射学家确认为真阳性,使检出率提高20.9%(23/110)或占全部研究的0.88%;敏感度96.36%、特异度99.56%、阳性预测值90.6%、阴性预测值99.84%。
要点
- 算法标记34例疑似漏诊动脉瘤,67%(23/34)经至少两名神经放射学家确认为真阳性。
- 漏诊动脉瘤多较小(≤3 mm),算法检出使检出率提高20.9%(23/110)或占全部研究的0.88%。
- 算法敏感度96.36%、特异度99.56%、阳性预测值90.6%、阴性预测值99.84%,假阴性4例。
核心结论
- 深度学习系统有潜力检测漏诊的颅内动脉瘤;本队列漏诊动脉瘤主要为小动脉瘤,根据临床特征和动脉瘤破裂危险因素,随访或诊断性数字减影血管造影可能仍有必要。
研究设计与样本
- 单中心回顾性研究,连续纳入2020年2月18日至2022年7月31日成人头部CTA共2,615例;使用自然语言处理分类报告、卷积神经网络分析图像,不一致病例由三名神经放射学家多数投票确定参考标准。
关键影像表现/征象
- 漏诊的颅内动脉瘤多数较小(≤3 mm)。
诊断标准与关键数值
- 算法标记34例疑似漏诊动脉瘤,其中67%(23/34)经至少两名神经放射学家确认为真阳性。
- 算法检出使检出率提高20.9%(23/110)或占全部研究的0.88%。
- 敏感度96.36%、特异度99.56%、阳性预测值90.6%、阴性预测值99.84%,假阴性4例。
临床应用与阅片要点
- 作者指出,尽管本队列漏诊动脉瘤主要为小动脉瘤,根据临床特征和动脉瘤破裂危险因素,随访或诊断性数字减影血管造影可能仍有必要。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The early identification of intracranial aneurysms (IAs) enables risk stratification and the timely initiation of optimal management. This study aimed to identify patients with missed aneurysms for follow-up and possible treatment, and to evaluate the effectiveness of a commercial deep learning algorithm in retrospectively detecting missed IAs on CTA.
METHODS: All consecutive head CTA studies of adult patients performed at a single referral center between February 18, 2020, and July 31, 2022, were retrospectively collected. A machine learning algorithm using natural language processing (NLP) classified radiology reports as positive or negative for aneurysms, and a convolutional neural network (CNN) algorithm analyzed the imaging data. Concordant results with the original reports were accepted as ground truth, while discordant cases were reviewed by three neuroradiologists, with majority voting determining the reference standard.
RESULTS: A total of 2,615 head CTA studies were analyzed. the algorithm flagged 34 suspected missed aneurysms, with 67% (23/34) confirmed as true positives by at least two neuroradiologists. This improved detection by 20.9% (23/110) or 0.88% of all studies. Most missed aneurysms were small (≤ 3 mm). There were 4 false negatives, resulting in a sensitivity of 96.36%, specificity of 99.56%, positive predictive value of 90.6%, and negative predictive value of 99.84%.
CONCLUSION: This study highlights the potential of deep learning systems to detect missed intracranial aneurysms. Although the missed aneurysms in this cohort were predominantly small, follow-up or diagnostic digital subtraction angiography may still be warranted, depending on clinical characteristics and risk factors for aneurysm rupture.
引用
- Sobeh T, Shrot S, Bakon M, et al. Retrospective detection of missed intra-cranial aneurysms on computed tomography angiography using a commercial deep learning algorithm. Neuroradiology. 2025. PMID: 41091156. doi:10.1007/s00234-025-03810-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。