混合融合模型在灰阶超声中有效鉴别腮腺良恶性肿瘤
本研究回顾性分析两个中心328例病理确诊的腮腺肿瘤患者,构建整合影像组学与迁移学习的混合融合模型DLRN。内部和外部验证队列中DLRN的AUC分别为0.931和0.934,判别能力最强;在DLR辅助下住院医师、主治医师和主任医师的诊断准确率分别提高6.6%、6.5%和1.2%。
要点
- DLRN在内部和外部验证队列AUC分别为0.931和0.934,判别能力优于临床、影像组学、深度迁移学习和DLR模型。
- 在DLR辅助下住院医师、主治医师和主任医师诊断准确率分别提高6.6%、6.5%和1.2%。
- 模型基于灰阶超声图像提取影像组学特征并融合迁移学习预测概率,用于鉴别腮腺良恶性肿瘤。
核心结论
- 混合融合模型DLRN显著提升腮腺良恶性肿瘤的诊断性能,可有效辅助超声医师做出更准确的诊断。
研究设计与样本
- 回顾性分析两个中心共328例经病理确诊的腮腺肿瘤患者,基于超声图像提取影像组学特征输入八种机器学习分类器构建Rad模型,图像输入七种迁移学习网络构建DTL模型,决策融合构建DLR模型,再结合临床特征构建DLRN模型;采用ROC曲线、校准曲线、决策曲线分析和Hosmer-Lemeshow检验评估模型性能。
诊断标准与关键数值
- 内部验证队列AUC:临床模型0.891、Rad模型0.809、DTL模型0.905、DLR模型0.932、DLRN模型0.931;外部验证队列AUC:临床模型0.734、Rad模型0.860、DTL模型0.782、DLR模型0.828、DLRN模型0.934;DLR辅助下住院医师、主治医师和主任医师诊断准确率分别提高6.6%、6.5%和1.2%。
临床应用与阅片要点
- 作者认为DLRN可有效辅助超声医师更准确鉴别腮腺良恶性肿瘤,并在DLR辅助下住院医师、主治医师和主任医师诊断准确率分别提高6.6%、6.5%和1.2%。
局限性
- 本研究为回顾性分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop a hybrid fusion model-deep learning radiomics nomograms (DLRN), integrating radiomics and transfer learning for assisting sonographers differentiate benign and malignant parotid gland tumors.
METHODS: This study retrospectively analyzed a total of 328 patients with pathologically confirmed parotid gland tumors from two centers. Radiomics features extracted from ultrasound images were input into eight machine learning classifiers to construct Radiomics (Rad) model. Additionally, images were also input into seven transfer learning networks to construct deep transfer learning (DTL) model. The prediction probabilities from these two models were combined through decision fusion to construct a DLR model. Clinical features were further integrated with the prediction probabilities of the DLR model to develop the DLRN model. The performance of these models was evaluated using receiver operating characteristic curve analysis, calibration curve, decision curve analysis and the Hosmer-Lemeshow test.
RESULTS: In the internal and external validation cohorts, compared with Clinic (AUC = 0.891 and 0.734), Rad (AUC = 0.809 and 0.860), DTL (AUC = 0.905 and 0.782) and DLR (AUC = 0.932 and 0.828), the DLRN model demonstrated the greatest discriminative ability (AUC = 0.931 and 0.934), showing the best discriminative power. With the assistance of DLR, the diagnostic accuracy of resident, attending and chief physician increased by 6.6%, 6.5% and 1.2%, respectively.
CONCLUSION: The hybrid fusion model DLRN significantly enhances the diagnostic performance for benign and malignant tumors of the parotid gland. It can effectively assist sonographers in making more accurate diagnoses.
引用
- Mao Y, Jiang LP, Wang JL, et al. Hybrid Fusion Model for Effective Distinguishing Benign and Malignant Parotid Gland Tumors in Gray-Scale Ultrasonography. Ultrasound Med Biol. 2025. PMID: 41015751. doi:10.1016/j.ultrasmedbio.2025.06.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。