开源AI用于股外侧肌与脂肪组织分割以评估肌肉大小与质量

Open-Source AI for Vastus Lateralis and Adipose Tissue Segmentation to Assess Muscle Size and Quality.
PubMed 文献 · Ultrasound Med Biol · 2025-09-14

研究开发开源AI模型,在44名前交叉韧带重建参与者的612张超声图像上训练,在14名参与者的50张图像上测试,分割股外侧肌与皮下脂肪组织的Dice系数分别为0.9654和0.9095,模型预测与手动测量在横截面积、回声强度及皮下脂肪厚度上一致性高。

要点

  • 模型在B型超声图像上分割股外侧肌与皮下脂肪组织,Dice系数分别为0.9654和0.9095。
  • 模型预测与手动测量横截面积ICC=0.986、回声强度ICC=0.991、皮下脂肪厚度ICC=0.996。
  • 横截面积测量SEM为1.15 cm²,回声强度SEM为1.28–1.78 a.u.。

核心结论

  • 开源AI模型能准确分割B型超声图像中的股外侧肌与皮下脂肪组织,实现肌肉大小与质量的自动测量。

研究设计与样本

  • 在44名前交叉韧带重建参与者的612张超声图像上训练,在14名独特参与者的50张图像测试集上评估泛化性,采用ResNet50骨干的U-Net架构进行分割,以Dice系数和交并比评估性能。

关键影像表现/征象

  • 皮下脂肪组织分割Dice系数为0.9095,股外侧肌分割Dice系数为0.9654。
  • 模型预测与手动测量横截面积ICC=0.986,回声强度ICC=0.991,皮下脂肪厚度ICC=0.996。

诊断标准与关键数值

  • 横截面积测量SEM为1.15 cm²,回声强度测量SEM为1.28–1.78 a.u.。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Ultrasound imaging is a clinically feasible method for assessing muscle size and quality, but manual processing is time-consuming and difficult to scale. Existing artificial intelligence (AI) models measure muscle cross-sectional area, but they do not include assessments of muscle quality or account for the influence of subcutaneous adipose tissue thickness on echo intensity measurements. We developed an open-source AI model to accurately segment the vastus lateralis and subcutaneous adipose tissue in B-mode images for automating measurements of muscle size and quality.

METHODS: The model was trained on 612 ultrasound images from 44 participants who had anterior cruciate ligament reconstruction. Model generalizability was evaluated on a test set of 50 images from 14 unique participants. A U-Net architecture with ResNet50 backbone was used for segmentation. Performance was assessed using the Dice coefficient and Intersection over Union (IoU). Agreement between model predictions and manual measurements was evaluated using intraclass correlation coefficients (ICCs), R² values and standard errors of measurement (SEM).

RESULTS: Dice coefficients were 0.9095 and 0.9654 for subcutaneous adipose tissue and vastus lateralis segmentation, respectively. Excellent agreement was observed between model predictions and manual measurements for cross-sectional area (ICC = 0.986), echo intensity (ICC = 0.991) and subcutaneous adipose tissue thickness (ICC = 0.996). The model demonstrated high reliability with low SEM values for clinical measurements (cross-sectional area: 1.15 cm², echo intensity: 1.28-1.78 a.u.).

CONCLUSION: We developed an open-source AI model that accurately segments the vastus lateralis and subcutaneous adipose tissue in B-mode ultrasound images, enabling automated measurements of muscle size and quality.