文献速递头颈骨肌MR

颞下颌关节MRI深度学习重建:诊断可互换性、图像质量与扫描时间缩短

Deep learning reconstruction for temporomandibular joint MRI: diagnostic interchangeability, image quality, and scan time reduction.
PubMed 文献 · Eur Radiol · 2025-09-25

本研究纳入88例疑似颞下颌关节 disorder 患者共176个颞下颌关节,同次 session 分别行常规与深度学习重建的矢状面 PDW 及 T2W FS MRI。结果显示深度学习重建对椎间盘形态、位置及关节积液的诊断与常规 MRI 等价(等价指数<3%,95%CI 在±5%内),噪声降低、SNR/CNR 提高(PDW 椎间盘 SNR 除外,p=0.189),扫描时间缩短49.2%。

要点

  • 深度学习重建颞下颌关节 MRI 对椎间盘形态、位置及积液的诊断与常规 MRI 可互换。
  • 深度学习重建降低 PDW 和 T2W FS 序列噪声并提高 SNR/CNR,但 PDW 椎间盘 SNR 无显著差异。
  • 深度学习重建使扫描时间缩短49.2%,图像质量整体改善。

核心结论

  • 深度学习重建的颞下颌关节 MRI 与常规 MRI 具有诊断可互换性,图像质量改善且扫描时间更短。

研究设计与样本

  • 单次 session 内对疑似颞下颌关节 disorder 患者行常规与深度学习重建的矢状面 PDW 及 T2W FS MRI,纳入88例患者共176个颞下颌关节,由3名口腔放射科医生独立评估。

关键影像表现/征象

  • 深度学习重建在 PDW 和 T2W FS 序列上显著降低噪声(p<0.05),同时保持锐利度和伪影水平。
  • 除 PDW 序列椎间盘 SNR 外(p=0.189),其余 SNR 和 CNR 均显著改善(p<0.05)。

诊断标准与关键数值

  • 诊断可互换性以观察者间一致性的95%CI在±5%内定义为等价,深度学习重建对椎间盘形态、位置及积液的等价指数<3%。
  • 图像质量采用5分制评估锐利度、噪声、伪影和整体质量。

临床应用与阅片要点

  • 深度学习重建可用于颞下颌关节 MRI 以缩短扫描时间并改善图像质量,且不损害对椎间盘形态、位置及积液的诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic interchangeability, image quality, and scan time of deep learning (DL)-reconstructed magnetic resonance imaging (MRI) compared with conventional MRI for the temporomandibular joint (TMJ).

MATERIALS AND METHODS: Patients with suspected TMJ disorder underwent sagittal proton density-weighted (PDW) and T2-weighted fat-suppressed (T2W FS) MRI using both conventional and DL reconstruction protocols in a single session. Three oral radiologists independently assessed disc shape, disc position, and joint effusion. Diagnostic interchangeability for these findings was evaluated by comparing interobserver agreement, with equivalence defined as a 95% confidence interval (CI) within ±5%. Qualitative image quality (sharpness, noise, artifacts, overall) was rated on a 5-point scale. Quantitative image quality was assessed by measuring the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the condyle, disc, and background air. Image quality scores were compared using the Wilcoxon signed-rank test, and SNR/CNR using paired t-tests. Scan times were directly compared.

RESULTS: A total of 176 TMJs from 88 patients (mean age, 37 ± 16 years; 43 men) were analyzed. DL-reconstructed MRI demonstrated diagnostic equivalence to conventional MRI for disc shape, position, and effusion (equivalence indices < 3%; 95% CIs within ±5%). DL reconstruction significantly reduced noise in PDW and T2W FS sequences (p < 0.05) while maintaining sharpness and artifact levels. SNR and CNR were significantly improved (p < 0.05), except for disc SNR in PDW (p = 0.189). Scan time was reduced by 49.2%.

CONCLUSION: DL-reconstructed TMJ MRI is diagnostically interchangeable with conventional MRI, offering improved image quality with a shorter scan time.

KEY POINTS: Question Long MRI scan times in patients with temporomandibular disorders can increase pain and motion-related artifacts, often compromising image quality in diagnostic settings. Findings DL reconstruction is diagnostically interchangeable with conventional MRI for assessing disc shape, disc position, and effusion, while improving image quality and reducing scan time. Clinical relevance DL reconstruction enables faster and more tolerable TMJ MRI workflows without compromising diagnostic accuracy, facilitating broader adoption in clinical settings where long scan times and motion artifacts often limit diagnostic efficiency.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jo GD, Jeon KJ, Choi YJ, et al. Deep learning reconstruction for temporomandibular joint MRI: diagnostic interchangeability, image quality, and scan time reduction. Eur Radiol. 2025. PMID: 40996510. doi:10.1007/s00330-025-12029-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。