文献速递外周血管泌尿生殖MRDSA

改良平衡稳态自由进动技术非增强MRA在肾动脉瘤栓塞术后随访中的评估

The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy.
PubMed 文献 · Abdom Radiol (NY) · 2025-09-10

研究纳入2013年6月至2024年7月间57例接受栓塞治疗的肾动脉瘤患者,其中14例患者的15个肾动脉瘤在栓塞后12个月接受改良b-SSFP联合ASL的非增强MRA及DSA随访;15组影像结果完全一致,12个完全闭塞、3个不完全闭塞,无动脉瘤增大及破裂或肾梗死等不良事件,提示该NC-MRA与DSA评估再通一致性良好,可能作为可靠的无创随访方式。

要点

  • 栓塞后12个月行改良b-SSFP联合ASL的非增强MRA,与DSA结果完全一致。
  • NC-MRA上动脉瘤内无高信号提示完全闭塞,DSA上无对比剂强化定义为完全闭塞。
  • 随访期间无动脉瘤增大,无破裂或肾梗死等不良事件。

核心结论

  • 改良b-SSFP联合ASL的非增强MRA在评估肾动脉瘤栓塞术后再通方面与DSA一致性良好,可能作为可靠的无创随访方式。

研究设计与样本

  • 单臂影像学比较研究,57例肾动脉瘤患者中14例患者的15个动脉瘤在栓塞后12个月接受NC-MRA和DSA随访,以DSA为参考标准,栓塞时间为2013年6月至2024年7月。

关键影像表现/征象

  • NC-MRA上动脉瘤内无高信号提示完全闭塞,DSA上动脉瘤内无对比剂强化定义为完全闭塞。
  • 15个动脉瘤中12个完全闭塞、3个不完全闭塞,随访期间无动脉瘤增大。
  • 15组随访MRA与DSA图像结果完全一致。

诊断标准与关键数值

  • NC-MRA完全闭塞标准:动脉瘤内无高信号。
  • DSA完全闭塞标准:动脉瘤内无对比剂强化。

临床应用与阅片要点

  • 栓塞后12个月可行改良b-SSFP联合ASL的非增强MRA随访,并与DSA结果对照。
  • 判读时以动脉瘤内有无高信号作为闭塞与再通的判断依据。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility and clinical utility of non-contrast magnetic resonance angiography (NC-MRA) using a modified balanced steady-state free precession (b-SSFP) technique combined with arterial spin labeling (ASL) for post-embolotherapy follow-up of renal artery aneurysms (RAAs), with digital subtraction angiography (DSA) as the reference standard.

METHOD: A total of 57 patients with RAAs underwent embolotherapy between June 2013 and July 2024. Among them, 15 RAAs from 14 patients underwent post-embolization surveillance with the NC-MRA and DSA. NC-MRA was performed at 12 months after coil embolization, followed by DSA. On NC-MRA images, complete occlusion is indicated by the absence of high signal within the aneurysm, whereas on DSA images, complete occlusion is defined as the absence of contrast enhancement within the aneurysm. We compare the NC-MRA and DSA results for each aneurysm during follow-up.

RESULTS: Of the 15 aneurysms, 12 achieved complete occlusion and 3 exhibited incomplete occlusion. There was no aneurysmal growth, and no adverse events such as rupture or renal infarction occurred. We acquired 15 groups of follow-up MRA and DSA images, and the results were in perfect concordance.

CONCLUSION: The NC-MRA using the modified b-SSFP combined with ASL shows good agreement with DSA in assessing recanalization of RAAs after embolotherapy and may serve as a reliable, non-invasive follow-up modality.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang P, Yan Z, Li P, et al. The evaluation of non-contrast MRA using a modified balanced steady state free precession technique in the follow-up of renal artery aneurysm after embolotherapy. Abdom Radiol (NY). 2025. PMID: 40928539. doi:10.1007/s00261-025-05193-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。