髌骨脱位或半脱位患者胫骨结节-Roman弓距离与胫骨结节-滑车沟距离的比较
回顾性分析259例患者和262例对照的膝关节MRI和/或CT,比较胫骨结节-滑车沟(TT-TG)与胫骨结节-Roman弓(TT-RA)距离,评估TT-RA的可靠性和可重复性,并用ROC分析确定手术治疗病理阈值。TT-RA在患者与对照组间差异显著,其ICC值高于TT-TG,MRI阈值TT-RA>17.30 mm、TT-TG>13.30 mm,CT阈值TT-RA>18.80 mm、TT-TG>15.60 mm。
要点
- TT-RA距离在髌骨脱位/半脱位患者中可靠且可重复,ICC值高于TT-TG。
- MRI手术参考阈值:TT-RA>17.30 mm、TT-TG>13.30 mm、TT-PCL>23.8 mm、滑车沟角>146°。
- CT手术参考阈值:TT-RA>18.80 mm、TT-TG>15.60 mm、TT-PCL>21.5 mm、滑车沟角>148°。
核心结论
- TT-RA距离是定位胫骨结节的可靠且可重复的方法,可靠性高于TT-TG。
- TT-RA阈值17.3 mm(MRI)和18.8 mm(CT)可指导手术指征。
研究设计与样本
- 回顾性分析纳入259例患者和262例对照的膝关节MRI和/或CT检查。
- 由两名放射科医生测量TT-RA、TT-TG、胫骨结节-后交叉韧带(TT-PCL)距离、Roman弓高度、滑车沟角和股骨髁总宽度,并评估滑车形态。
- 采用Student t检验比较测量值,组内相关系数(ICC)评估可靠性和可重复性,ROC分析确定病理阈值,Pearson相关比较TT-TG与TT-RA。
关键影像表现/征象
- 患者组与对照组的TT-RA、TT-TG、TT-PCL距离和滑车沟角差异显著(p < 0.001)。
- MRI和CT亚组分析也显示显著差异(p < 0.001)。
诊断标准与关键数值
- MRI阈值:TT-RA > 17.30 mm,TT-TG > 13.30 mm,TT-PCL > 23.8 mm,滑车沟角 > 146°。
- CT阈值:TT-RA > 18.80 mm,TT-TG > 15.60 mm,TT-PCL > 21.5 mm,滑车沟角 > 148°。
- TT-RA的ICC值在可重复性和可靠性均 > 0.959和 > 0.988。
- TT-TG与TT-RA距离强相关(r = 0.867,p < 0.001)。
临床应用与阅片要点
- TT-RA距离可在临床实践中作为TT-TG距离的替代方法,用于髌骨半脱位和脱位患者的手术治疗指征。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare tibial tubercle-trochlear groove (TT-TG) and tibial tubercle-Roman arch (TT-RA) distances in patients with patellar dislocation or subluxation, evaluate TT-RA reliability and reproducibility, and determine pathological threshold values for surgical treatment using magnetic resonance imaging (MRI) and computed tomography (CT).
MATERIALS AND METHODS: Retrospective analysis included 259 patient and 262 control examinations of knee MRIs and/or CTs performed. TT-RA, TT-TG, and tibial tubercle-posterior cruciate ligament (TT-PCL) distances, Roman Arch height, trochlear sulcus angle, and total femoral condyle width were measured by two radiologists, and trochlear morphology was assessed. Measurements were compared using the Student's t-test. Reliability and reproducibility were evaluated using intraclass correlation coefficients (ICC). Receiver Operating Characteristic (ROC) analysis determined pathological thresholds, and Pearson correlation compared TT-TG and TT-RA.
RESULTS: TT-RA, TT-TG, TT-PCL distances, and trochlear sulcus angles were significantly different between patient and control groups (p < 0.001). Subgroup analyses for MRI and CT also showed significant differences (p < 0.001). TT-RA distance had higher ICC values for reproducibility and reliability (> 0.959; > 0.988). ROC analysis determined MRI thresholds as TT-RA > 17.30 mm, TT-TG > 13.30 mm, TT-PCL > 23.8 mm, and trochlear sulcus angle > 146°; for CT, TT-RA > 18.80 mm, TT-TG > 15.60 mm, TT-PCL > 21.5 mm, and trochlear sulcus angle > 148°. Strong correlation was found between TT-TG and TT-RA distances (r = 0.867, p < 0.001).
CONCLUSION: TT-RA distance is a reliable and reproducible method for tibial tubercle localization and shows higher reliability than TT-TG. Thresholds of 17.3 mm (MRI) and 18.8 mm (CT) for TT-RA can guide surgical indications.
KEY POINTS: Question The reliable measurement of the tibial tubercle lateralization is crucial for planning the treatment of patients with patellar dislocation/subluxation. Findings The tibial tubercle-Roman arch (TT-RA) distance is more reliable and repeatable than the tibial tubercle-trochlear groove (TT-TG) distance in patients with patellar dislocation and subluxation. Clinical relevance TT-RA distance can be used in clinical practice as an alternative to tibial tubercle-trochlear groove (TT-TG) distance for surgical treatment indications in patients with patellar subluxation and dislocation.
引用
- Aksakal ET, Soydan H, Çay N, et al. Comparison of tibial tubercle-Roman arch distance and tibial tubercle-trochlear groove distance in patients with patellar dislocation or subluxation. Eur Radiol. 2025. PMID: 40911062. doi:10.1007/s00330-025-11982-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。