文献速递骨肌MR

一种用于评估腰椎骨质疏松的新校准椎体骨质量评分

A novel calibration of vertebral bone quality score for the evaluation of osteoporosis in the lumbar spine.
PubMed 文献 · Clin Radiol · 2025-08-26

本研究提出将椎体骨质量(VBQ)评分校准至皮下脂肪的新型校准VBQ评分,以克服1.5 T与3.0 T磁场对评分的影响。回顾性纳入83例同时接受1.5-T和3.0-T MRI检查的患者,结果显示校准VBQ评分不受磁场影响,且对骨质疏松的诊断效能优于VBQ评分和改良VBQ评分。

要点

  • 校准VBQ评分将脂肪浸润测量校准至皮下脂肪,可消除1.5 T与3.0 T磁场差异的影响。
  • 传统VBQ评分和改良VBQ评分在1.5 T与3.0 T磁场间存在显著差异。
  • 校准VBQ评分对骨质疏松的诊断效能优于传统VBQ评分和改良VBQ评分。

核心结论

  • 校准VBQ评分可克服1.5 T与3.0 T磁场间的不一致性,与传统VBQ评分相比,可被视为更好的骨质疏松筛查工具。

研究设计与样本

  • 回顾性收集同时接受1.5-T和3.0-T MRI检查的患者83例(平均年龄67.7±8.3岁),比较自身配对VBQ评分、改良VBQ评分和校准VBQ评分在不同磁场间的差异,并进行相关分析和ROC曲线分析。

诊断标准与关键数值

  • 自身配对分析显示1.5-T和3.0-T磁场对校准VBQ评分无影响,而对VBQ评分和改良VBQ评分有显著影响;相关分析和ROC曲线分析显示校准VBQ评分对骨质疏松的诊断效果优于VBQ评分和改良VBQ评分。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: The magnetic resonance imaging (MRI)-based vertebral bone quality (VBQ) score can be used as a screening tool for identifying patients who may have osteoporosis; however, a significant influence of the magnetic fields of 1.5 T and 3.0 T on the score has been reported. The purpose of this study was to introduce a novel calibration to overcome the problem.

MATERIALS AND METHODS: We standardised fat infiltration measurement by calibrating the VBQ score to subcutaneous fat, terming it the calibrated-VBQ score. We retrospectively collected patients who underwent both the 1.5-T and 3.0-T MRI examinations. The self-paired VBQ score, a modified-VBQ score, and the calibrated-VBQ score were compared between different magnetic fields. Correlation analysis and receiver operating characteristic (ROC) curve analysis were performed.

RESULTS: The study included 83 patients (mean age: 67.7 ± 8.3 years). The analysis of self-paired patients revealed that the 1.5-T and 3.0-T magnetic fields had no influence on the calibrated-VBQ score, whereas a significant influence on the VBQ scores and the modified-VBQ score was found. By correlation analysis and ROC curve analysis, a better diagnostic effect of the calibrated-VBQ score for osteoporosis could be found than with the VBQ score and the modified-VBQ score.

CONCLUSION: The calibrated-VBQ score could overcome the inconsistency between the magnetic fields of 1.5 T and 3.0 T, and it could be considered as a better screening tool for osteoporosis compared with the traditional VBQ scores.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Hu F, Jing F, Zhao D, et al. A novel calibration of vertebral bone quality score for the evaluation of osteoporosis in the lumbar spine. Clin Radiol. 2025. PMID: 40974756. doi:10.1016/j.crad.2025.107063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。