基于超声的列线图联合超声造影与常规超声特征提高甲状旁腺腺瘤与颈部淋巴结的术前鉴别诊断
回顾性纳入54例原发性甲状旁腺功能亢进症患者和174枚甲状腺乳头状癌患者的颈部淋巴结,构建整合常规超声与超声造影特征的列线图,用于鉴别甲状旁腺腺瘤与中央区颈部淋巴结;模型AUC为0.915,高于常规超声模型0.874和超声造影模型0.791。
要点
- 联合常规超声与超声造影的列线图鉴别甲状旁腺腺瘤与中央区颈部淋巴结的AUC为0.915。
- 常规超声模型AUC为0.874,超声造影模型AUC为0.791,联合模型诊断效能更高。
- 3个常规超声特征和2个超声造影特征是鉴别甲状旁腺腺瘤与中央区颈部淋巴结的独立特征。
核心结论
- 联合常规超声与超声造影特征构建的列线图可提高甲状旁腺腺瘤与中央区颈部淋巴结的术前鉴别诊断效能,推荐对疑似甲状旁腺病变使用超声造影以增强超声的诊断效用。
研究设计与样本
- 回顾性纳入54例原发性甲状旁腺功能亢进症患者(术前行高分辨率超声和超声造影,随后行甲状旁腺切除术)及174枚甲状腺乳头状癌患者的颈部淋巴结(行高分辨率超声和超声造影,随后行单侧、次全或全甲状腺切除联合中央区颈淋巴结清扫)。
诊断标准与关键数值
- 联合模型(常规超声+超声造影)鉴别甲状旁腺腺瘤与中央区颈部淋巴结的AUC为0.915,高于常规超声模型AUC 0.874和超声造影模型AUC 0.791;3个常规超声特征和2个超声造影特征为独立鉴别特征。
临床应用与阅片要点
- 作者推荐对疑似甲状旁腺病变使用超声造影技术以增强超声的诊断效用;列线图整合了3个常规超声特征和2个超声造影特征用于鉴别甲状旁腺腺瘤与中央区颈部淋巴结。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Precise preoperative localization of parathyroid gland lesion is essential for guiding surgery in primary hyperparathyroidism (PHPT). The aim of our study was to investigate the contrast-enhanced ultrasound (CEUS) characteristics of parathyroid gland adenoma (PGA) and to evaluate whether PGA can be differentiated from central cervical lymph nodes (CCLN).
METHODS: Fifty-four consecutive patients with PHPT were retrospectively enrolled and underwent preoperative imaging with high-resolution ultrasound (US) and CEUS, and underwent subsequent parathyroidectomy. One hundred seventy-four lymph nodes of papillary thyroid carcinomas (PTC) patients were examined by high-resolution US and CEUS, and underwent unilateral, subtotal, or total thyroidectomy with central neck dissection were enrolled. By incorporating US and CEUS characteristics, a predictive model presented as a nomogram was developed, and their performance and utility were evaluated by plotting receiver operating characteristic (ROC) curves, calibration curves and decision curve analysis (DCA).
RESULTS: Three US characteristics and 2 CEUS characteristics were independent characteristics related to PGA for their differentiation from CCLN, and were obtained for machine learning model construction. The area under the receiver characteristic curve (AUC) of the US + CEUS model was 0.915, was higher than the other US model (0.874) and CEUS model (0.791).
CONCLUSION: It is recommended that CEUS techniques be used to enhance the diagnostic utility of US in cases of suspected parathyroid lesions.
ADVANCES IN KNOWLEDGE: This is the first study to use a combination of US + CEUS to build a nomogram to distinguish between PGA and CCLN, filling a gap in the existing literatures.
引用
- Xu Y, Zuo Z, Peng Q, et al. A novel ultrasound-based nomogram using contrast-enhanced and conventional ultrasound features to improve preoperative diagnosis of parathyroid adenomas versus cervical lymph nodes. Br J Radiol. 2026. PMID: 40973087. doi:10.1093/bjr/tqaf230