文献速递乳腺技术与安全US

常规超声联合弹性成像或超声造影诊断乳腺非肿块型病变的获益:系统综述与Meta分析

Benefits of Conventional Ultrasound Combined With Elastography or Contrast-Enhanced Ultrasound for Breast Non-mass Lesions: A Systematic Review and Meta-Analysis.
PubMed 文献 · Ultrasound Med Biol · 2025-09-13

该系统综述与Meta分析纳入14项研究共1040个乳腺非肿块型病变(533个恶性),评估常规超声联合弹性成像或超声造影的诊断效能。常规超声联合弹性成像或超声造影可提高特异度,诊断效能满意;BI-RADS分类阈值、造影剂剂量和研究设计是异质性来源。

要点

  • 常规超声诊断乳腺非肿块型病变敏感度高(93%)但特异度低(52%)。
  • 联合弹性成像或超声造影可将特异度分别提高至71%和79%。
  • BI-RADS分类阈值、造影剂剂量和研究设计是异质性来源。

核心结论

  • 在常规超声基础上联合弹性成像或超声造影可提高诊断乳腺非肿块型病变的特异度,诊断效能满意。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Cochrane Library、Web of Science和Embase数据库至2023年10月,纳入14项研究共1040个乳腺非肿块型病变(533个恶性)。

诊断标准与关键数值

  • 常规超声:汇总敏感度93%(95%CI 82-98),特异度52%(95%CI 33-70),阳性似然比1.9(95%CI 1.4-2.8),阴性似然比0.13(95%CI 0.06-0.29),诊断比值比15(95%CI 7-33),SROC曲线下面积84%(95%CI 80-87)。
  • 常规超声联合弹性成像:汇总敏感度93%(95%CI 87-96),特异度71%(95%CI 54-84),阳性似然比3.2(95%CI 2.0-55.4),阴性似然比0.10(95%CI 0.06-0.17),诊断比值比33(95%CI 19-56),SROC曲线下面积93%(95%CI 90-95)。
  • 常规超声联合超声造影:汇总敏感度91%(95%CI 85-95),特异度79%(95%CI 71-85),阳性似然比4.3(95%CI 3.1-6.0),阴性似然比0.11(95%CI 0.06-0.20),诊断比值比40(95%CI 18-87),SROC曲线下面积91%(95%CI 88-93)。

临床应用与阅片要点

  • 对常规超声发现的乳腺非肿块型病变,联合弹性成像或超声造影可提高诊断特异度。
  • BI-RADS分类阈值、造影剂剂量和研究设计是诊断异质性的影响因素。

局限性

  • BI-RADS分类阈值、造影剂剂量和研究设计是异质性来源。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This systematic review and meta-analysis analyzed the effectiveness of combining conventional ultrasound (US) with ultrasound elastography (UE) or contrast-enhanced ultrasound (CEUS) for diagnosing breast non-mass lesions (NMLs).

METHODS: PubMed, Cochrane Library, Web of Science and Embase databases were searched up to Oct. 2023. Pooled sensitivity and specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), post-test probability and the area under the summary receiver operating characteristic (SROC) curve were used to evaluate diagnostic efficacy.

RESULTS: A total of 1040 NMLs (533 malignant NMLs) from 14 studies were included. The pooled sensitivity, specificity, PLR, NLR and DOR of conventional US were 93% (95% confidence intervals [95% CI]: 82-98), 52% (95% CI: 33-70), 1.9 (95% CI: 1.4-2.8), 0.13 (95% CI: 0.06-0.29) and 15 (95% CI: 7-33). For the studies combined US with UE, the pooled sensitivity, specificity, PLR, NLR and DOR were 93% (95% CI: 87-96), 71% (95% CI: 54-84), 3.2 (95% CI: 2.0-55.4), 0.10 (95% CI: 0.06-0.17) and 33 (95% CI: 19-56). For the studies combined US with CEUS, the pooled sensitivity, specificity, PLR, NLR and DOR were 91% (95% CI: 85-95), 79% (95% CI: 71-85), 4.3 (95% CI: 3.1-6.0), 0.11 (95% CI: 0.06-0.20) and 40 (95% CI: 18-87). The area under the SROC curve was 84% (95% CI: 80-87), 93% (95% CI: 90-95) and 91% (95% CI: 88-93), respectively. We found no evidence of publication bias.

CONCLUSION: The addition of UE or CEUS to conventional US can improve the specificity and has satisfactory diagnostic performance for diagnosing breast NMLs. Threshold of Breast Imaging Reporting and Data System categories, dose of contrast agent and study design are factors contributing to heterogeneity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Lin S, Tang G, Luo Y, et al. Benefits of Conventional Ultrasound Combined With Elastography or Contrast-Enhanced Ultrasound for Breast Non-mass Lesions: A Systematic Review and Meta-Analysis. Ultrasound Med Biol. 2025. PMID: 40947376. doi:10.1016/j.ultrasmedbio.2025.08.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。