基于深度学习的多次激发乳腺扩散MRI:提升图像质量并减少变形
前瞻性研究纳入61例女性65个乳腺病灶,在3 T MRI上比较单次激发DWI与多次激发MUSE DWI的深度学习重建(MUSE DL)。MUSE DL较非DL的MUSE显著提升SNR,2次与4次激发MUSE DL图像变形均小于SS-DWI,且良恶性病灶ADC在三者间无显著差异。
要点
- MUSE DL可提升乳腺DWI信噪比并减少图像变形。
- MUSE DL与SS-DWI的良恶性病灶ADC值无显著差异。
- 2次与4次激发MUSE DL图像变形均小于SS-DWI。
核心结论
- MUSE DL可提升信噪比、减少图像变形,并保留病灶诊断准确性与ADC值。
研究设计与样本
- 前瞻性、经机构审查委员会批准的研究,纳入61例女性(平均年龄49.07岁±11.0,范围23-75岁)共65个乳腺病灶,使用3 T MRI扫描仪采集SS-DWI与多次激发MUSE DWI并经深度学习重建(MUSE DL)。
关键影像表现/征象
- MUSE DL在2次和4次激发设置下较非DL的MUSE显著提升图像质量。
- 2次与4次激发MUSE DL图像变形(HD 3.11 mm、2.58 mm)均显著小于SS-DWI(4.15 mm,P < 0.001)。
诊断标准与关键数值
- ADC在良性肿瘤中MUSE、MUSE DL与SS-DWI间差异无统计学意义(P = 0.154),恶性肿瘤中亦无统计学意义(P = 0.167)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the imaging performance of deep-learning reconstruction on multiplexed sensitivity encoding (MUSE DL) compared to single-shot diffusion-weighted imaging (SS-DWI) in the breast.
MATERIALS AND METHODS: In this prospective, institutional review board-approved study, both single-shot (SS-DWI) and multi-shot MUSE DWI were performed on patients. MUSE DWI was processed using deep-learning reconstruction (MUSE DL). Quantitative analysis included calculating apparent diffusion coefficients (ADCs), signal-to-noise ratio (SNR) within fibroglandular tissue (FGT), adjacent pectoralis muscle, and breast tumors. The Hausdorff distance (HD) was used as a distortion index to compare breast contours between T2-weighted anatomical images, SS-DWI, and MUSE images. Subjective visual qualitative analysis was performed using Likert scale. Quantitative analyses were assessed using Friedman's rank-based analysis with Bonferroni correction.
RESULTS: Sixty-one female participants (mean age 49.07 years ± 11.0 [standard deviation]; age range 23-75 years) with 65 breast lesions were included in this study. All data were acquired using a 3 T MRI scanner. The MUSE DL yielded significant improvement in image quality compared with non-DL MUSE in both 2-shot and 4-shot settings (SNR enhancement FGT 2-shot DL 207.8 % [125.5-309.3],4- shot DL 175.1 % [102.2-223.5]). No significant difference was observed in the ADC between MUSE, MUSE DL, and SS-DWI in both benign (P = 0.154) and malignant tumors (P = 0.167). There was significantly less distortion in the 2- and 4-shot MUSE DL images (HD 3.11 mm, 2.58 mm) than in the SS-DWI images (4.15 mm, P < 0.001).
CONCLUSIONS: MUSE DL enhances SNR, minimizes image distortion, and preserves lesion diagnosis accuracy and ADC values.
引用
- Chien N, Cho YH, Wang MY, et al. Deep learning based multi-shot breast diffusion MRI: Improving imaging quality and reduced distortion. Eur J Radiol. 2025. PMID: 40974694. doi:10.1016/j.ejrad.2025.112419
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。