文献速递泌尿生殖技术与安全US

定量超声造影评估脓毒症诱导急性肾损伤大鼠模型肾微循环与功能

Quantitative Contrast-Enhanced Ultrasound Assessment of Renal Microcirculation and Function in a Rat Model of Sepsis-Induced Acute Kidney Injury.
PubMed 文献 · Ultrasound Med Biol · 2025-09-16

研究将36只健康Sprague-Dawley大鼠分为脓毒症模型组(含重度和轻度亚组)与假手术对照组,模型亚组通过盲肠结扎穿刺诱导脓毒症相关急性肾损伤。定量超声造影显示模型组时间灌注参数较假手术组显著延长,血清肌酐和尿酸水平与时间灌注参数正相关,组织病理学证实急性肾损伤且重度亚组损伤更明显。结论认为定量超声造影可有效评估大鼠脓毒症相关急性肾损伤的肾灌注,对检测和监测肾功能变化有价值。

要点

  • 脓毒症相关急性肾损伤大鼠肾超声造影时间灌注参数较假手术组显著延长(均p<0.05)。
  • 血清肌酐与达峰时间、平均通过时间、上升时间、下降半时间正相关(r=0.695、0.669、0.704、0.394)。
  • 血清尿酸与达峰时间、平均通过时间、上升时间、下降半时间正相关(r=0.810、0.798、0.586、0.351)。

核心结论

  • 定量超声造影可有效评估大鼠脓毒症相关急性肾损伤的肾灌注,对检测和监测肾功能变化有价值。

研究设计与样本

  • 36只健康Sprague-Dawley大鼠分为脓毒症模型组(含重度和轻度亚组)与假手术对照组;模型亚组行盲肠结扎穿刺诱导脓毒症相关急性肾损伤,假手术组仅行开腹不结扎不穿刺;采集颈静脉血测血清肌酐和尿酸;行超声造影评估肾灌注并分析时间-强度曲线获取灌注参数;取肾组织行病理分析确认急性肾损伤。

诊断标准与关键数值

  • 脓毒症模型大鼠时间灌注参数达峰时间、上升时间、下降半时间和平均通过时间均显著长于假手术组(均p<0.05);血清肌酐与达峰时间、平均通过时间、上升时间、下降半时间正相关(r=0.695、0.669、0.704、0.394);血清尿酸与达峰时间、平均通过时间、上升时间、下降半时间正相关(r=0.810、0.798、0.586、0.351);均p<0.05。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This study aims to investigate the utility of quantitative contrast-enhanced ultrasound (CEUS) in both assessing renal perfusion and monitoring renal function in a rat model of sepsis-associated acute kidney injury (S-AKI).

METHODS: Thirty-six healthy Sprague-Dawley rats were divided into a sepsis model group (with severe and mild subgroups) and a sham-operated control group (Sham). The model subgroups underwent cecal ligation and puncture to induce S-AKI, while the Sham group received only a laparotomy without ligation or puncture. Jugular venous blood was collected to measure serum creatinine (Scr) and uric acid (UA) levels. CEUS was performed to evaluate renal perfusion and time-intensity curves were analyzed to derive perfusion parameters. The relationships between these CEUS-derived parameters and the serum biomarkers were examined. Finally, kidney tissue samples were harvested for pathological analysis to confirm AKI.

RESULTS: In the sepsis model rats, the time-based perfusion parameters-time to peak (TTP), rise time (RT), fall half-time (FHT) and mean transit time (MTT)-were all significantly longer than in the Sham group (all p < 0.05). Scr and UA levels correlated positively with TTP, MTT, RT and FHT (Scr: r = 0.695, 0.669, 0.704, 0.394; UA: r = 0.810, 0.798, 0.586, 0.351; all p < 0.05). Histopathological examination of renal tissues in the model subgroups revealed changes consistent with AKI, with the severe subgroup exhibiting more pronounced renal damage than the mild subgroup.

CONCLUSION: Quantitative CEUS can effectively evaluate renal perfusion in rats with S-AKI and is valuable for detecting and monitoring changes in renal function.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Liu P, Cai X, Chen H, et al. Quantitative Contrast-Enhanced Ultrasound Assessment of Renal Microcirculation and Function in a Rat Model of Sepsis-Induced Acute Kidney Injury. Ultrasound Med Biol. 2025. PMID: 40962609. doi:10.1016/j.ultrasmedbio.2025.08.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。