CT引导下钝头针经皮空芯针活检诊断胰腺肿瘤
这项回顾性队列研究纳入2021年10月至2023年10月连续103例接受CT引导下钝头针经皮空芯针活检的胰腺肿瘤患者,技术成功率100%,明确诊断率91.3%,准确率91.8%,敏感度与特异度均为100%,并发症率7.77%;难以到达组与常规组在诊断率、准确率和并发症率上无显著差异。作者认为该技术似乎安全有效,对难以到达的病灶亦然。
要点
- 总体技术成功率100%(103/103),明确诊断94例(91.3%,95%CI 84.1%-95.9%)。
- 准确率91.8%(95%CI 84.5%-96.4%),敏感度100%(95%CI 47.8%-100%),特异度100%(95%CI 96.0%-100%)。
- 难以到达组与常规组诊断率90.0% vs 93.9%(p=0.774)、准确率90.0% vs 93.9%(p=0.774)、并发症率7.1% vs 9.1%(p=0.730)均无显著差异。
核心结论
- CT引导下钝头针经皮空芯针活检似乎是一种安全有效的胰腺肿瘤诊断方法,即使对难以到达的肿瘤亦然。
研究设计与样本
- 回顾性队列研究,纳入2021年10月至2023年10月连续103例(男64例、女39例;平均年龄61±12.3岁,范围21-86岁)接受CT引导下钝头针经皮空芯针活检的胰腺病变患者,按术中影像分为难以到达组与常规组。
诊断标准与关键数值
- 总体技术成功率100%(103/103);明确诊断94例(91.3%,95%CI 84.1%-95.9%),不明确9例(8.7%,95%CI 4.1%-15.9%);准确率91.8%(95%CI 84.5%-96.4%),敏感度100%(95%CI 47.8%-100%),特异度100%(95%CI 96.0%-100%),阳性预测值38.5%(95%CI 13.9%-68.4%);并发症率7.77%(95%CI 3.4%-14.7%)。
临床应用与阅片要点
- 平均操作时间22.5±7.4分钟(四分位距16-22,范围8-47),针调整次数中位数5次(四分位距3.0-7.0,范围1-11)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To investigate the performance of CT-guided percutaneous CNB for the diagnosis of pancreatic tumors using a blunt-tip needle technique.
MATERIALS AND METHODS: This is a retrospective cohort study included 103 consecutive patients (64 males and 39 females; mean age 61±12.3 years;range 21-86) who underwent CT-guided percutaneous CNB of pancreatic lesions using a blunt-tip needle technique between October 2021 and October 2023. The procedures were divided into two subgroups: hard-to-reach group and conventional group based on intraprocedural images. Patient demographics and clinical characteristics including age, sex, lesion location and size were recorded, as well as the histopathologic report, the clinical and radiological follow-ups were reviewed. The technical success rate, diagnostic performance, and procedural data were calculated and compared between the two groups.
RESULTS: Within the 103 procedures, the overall technique success rate was 100% (103/103). There were 94 (91.3%, 95%CI 84.1%-95.9%) conclusive and 9 (8.7%, 95%CI 4.1%-15.9%) inconclusive results; the accuracy, sensitivity, specificity, positive and negative predictive values were 91.8% (95%CI 84.5%-96.4%), 100% (95%CI 47.8%-100%), 100% (95%CI 96.0%-100%), and 38.5% (95%CI 13.9%-68.4%), respectively. Complication rate was 7.77% (95%CI 3.4%-14.7%). The mean procedure duration was 22.5±7.4(interquartile range (IQR) 16-22, range:8-47) min and the median number of needle adjustments was 5 (IQR: 3.0, 7.0,range:1-11). There were no significant differences in diagnostic yield (90.0% versus 93.9%, p=0.774), accuracy (90.0% versus 93.9%, p=0.774), and complication rate (7.1% versus 9.1%, p=0.730) between the hard-to-reach group and conventional group.
CONCLUSION: CT-guided percutaneous CNB using a blunt-tip needle technique appears to be a safe and effective method for the diagnosis of pancreatic tumors, even for those that are difficult to reach.
引用
- Wang M, Zhou Z, Du K, et al. Computer Tomography (CT)-guided Percutaneous Core-needle Biopsy for the Diagnosis of Pancreatic Tumors Using a Blunt-tip Needle Technique. Acad Radiol. 2025. PMID: 40925788. doi:10.1016/j.acra.2025.07.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。