英国生物银行中身体脂肪与骨骼肌的自动容积MRI定量:对照专家手工分割的技术验证及与单层技术的比较

Automated volumetric MRI quantification of body fat and skeletal muscle in the UK Biobank: technical validation against expert manual segmentations and comparison with single-slice techniques.
PubMed 文献 · Abdom Radiol (NY) · 2025-09-08

研究纳入4905名英国生物银行有重复全身Dixon MRI扫描的个体,将新自动容积MRI与手工分割金标准及单层L3面积测量比较。新自动容积测量与手工金标准一致性极佳(ICC≥0.96,CoV≤3.8%),单层L3面积与对应体积相关性很强(VAT ρ=0.97、SAT ρ=0.94、SM ρ=0.95),各方法间可互换。

要点

  • 新自动容积MRI与手工分割金标准一致性极佳:ICC≥0.96,CoV≤3.8%,无明显偏倚。
  • 单层L3面积与对应体积相关性很强:VAT ρ=0.97、SAT ρ=0.94、SM ρ=0.95,均p<0.001。
  • 单层面积与体积的相关性在性别、年龄及心血管代谢特征各层中均保持优秀(中位ρ=0.95)。

核心结论

  • 手工分割、自动容积与半自动单层身体成分测量方法之间相关性稳健,方法可互换,应用时应根据实际考虑、操作差异和测量粒度而非技术性能选择方法。

研究设计与样本

  • 技术验证研究,纳入4905名英国生物银行有重复全身Dixon MRI扫描的个体,以100名受试者扫描的手工分割作为金标准,并与既往容积测量及新的半自动单层L3面积测量比较。

诊断标准与关键数值

  • 新自动容积测量与手工金标准一致性:ICC≥0.96、CoV≤3.8%;既往与新容积法VAT和SAT测量相关性:VAT ρ=0.99、SAT ρ=1(均p<0.001);单层L3面积与对应体积相关性:VAT ρ=0.97、SAT ρ=0.94、SM ρ=0.95(均p<0.001),按性别、年龄和心血管代谢特征分层中位ρ=0.95。

临床应用与阅片要点

  • 作者认为各方法可互换,具体应用时应根据实际考虑、操作差异和测量粒度而非技术性能来选择方法。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The escalating global incidence of obesity, cardiometabolic disease and sarcopenia necessitates reliable body composition measurement tools. MRI-based assessment is the gold standard, with utility in both clinical and drug trial settings. This study aims to validate a new automated volumetric MRI method by comparing with manual ground truth, prior volumetric measurements, and against a new method for semi-automated single-slice area measurements.

METHODS: 4905 individuals from the UK Biobank with repeat whole-body Dixon MRI scans were selected. MRI data were processed automatically to derive new (1) volumetric and (2) single-slice area measurements at L3 vertebral level for visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), and abdominal skeletal muscle (SM). For comparison, prior volumetric measurements of VAT and SAT were included. A separate set of scans from 100 subjects was randomly selected and body composition volumes and areas were manually segmented as ground truth.

RESULTS: The new automated volumetric measurements were found to have excellent agreement with manual ground truth with no substantial bias (ICC ≥ 0.96, CoV ≤ 3.8%). In the cohort of 4905 individuals (49% male, mean age 62 years ± 8, BMI 26 kg/m2 ± 4), we confirmed that prior and new volumetric methods of VAT and SAT measurement were very strongly correlated (VAT: ρ = 0.99; SAT: ρ = 1; both p < 0.001). Single-slice L3 area measurements demonstrated very strong correlations with corresponding volumes (for VAT ρ = 0.97, for SAT ρ = 0.94, for SM ρ = 0.95, all p < 0.001), and remained excellent across sex, age, and cardiometabolic characteristics (median ρ = 0.95).

CONCLUSION: We found robust correlations between manually segmented, automated volumetric, and semi-automated single-slice body composition methods. The interchangeability of these methods suggests that for each application the method should be selected according to practical considerations, operational differences and measurement granularity, rather than technical performance.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Nowak M, Núñez L, Hill CE, et al. Automated volumetric MRI quantification of body fat and skeletal muscle in the UK Biobank: technical validation against expert manual segmentations and comparison with single-slice techniques. Abdom Radiol (NY). 2025. PMID: 40924130. doi:10.1007/s00261-025-05170-w