文献速递儿科影像心血管USCT

以肺动脉分支数目异常为初始线索的胎儿心脏畸形产前诊断

Prenatal Diagnosis of Fetal Heart Malformation With Abnormal Number of Pulmonary Artery Branches as the Initial Clue.
PubMed 文献 · J Ultrasound Med · 2025-09-18

回顾性分析20例超声发现肺动脉分支数目异常的胎儿,将产前超声所见与出生后超声心动图、CT、手术、尸检及基因检测结果对照。异常分支包括1支15例(肺动脉吊带7例、单侧肺动脉缺如4例、单侧肺动脉起源异常4例)、3支2例、4支3例;3VT切面检出率63.2%,3支肺动脉分支切面100%,无名动脉冠状切面57.9%。结论认为上述三个切面是诊断关键,STIC-HD live flow可辅助显示血管连接。

要点

  • 肺动脉分支数目异常可作为胎儿心脏畸形产前超声筛查的初始线索,需系统扫查3VT、3支肺动脉分支及无名动脉冠状切面。
  • 3支肺动脉分支切面对异常分支的检出率为100%,高于3VT切面63.2%和无名动脉冠状切面57.9%。
  • STIC-HD live flow超声可辅助显示与肺动脉分支异常相关的血管连接。

核心结论

  • 3VT、3支肺动脉分支及无名动脉冠状切面是以肺动脉分支异常为主要特征的胎儿心脏畸形诊断的关键切面,STIC-HD live flow超声可辅助显示相关血管连接,识别1/3/4支肺动脉分支特征有助于系统评估胎儿心脏缺陷。

研究设计与样本

  • 回顾性分析20例产前超声发现肺动脉分支数目异常的胎儿,将产前超声所见与出生后超声心动图、CT、手术、尸检及基因检测结果对照,总结3VT、3支肺动脉分支及无名动脉冠状切面的超声特征与出现频率。

关键影像表现/征象

  • 1支肺动脉分支15例:肺动脉吊带7例、单侧肺动脉缺如4例、单侧肺动脉起源异常4例。
  • 3支肺动脉分支2例:孤立性左锁骨下动脉1例、孤立性左无名动脉1例,均伴右动脉导管缺如。
  • 4支肺动脉分支3例:孤立性左锁骨下动脉2例、孤立性左无名动脉1例,伴双动脉导管。
  • 伴发畸形包括法洛四联症、永存左上腔静脉、室间隔缺损、Berry综合征及鼻骨发育不良。

诊断标准与关键数值

  • 3VT切面对异常肺动脉分支的检出率为63.2%。
  • 3支肺动脉分支切面对异常肺动脉分支的检出率为100%。
  • 无名动脉冠状切面对异常肺动脉分支的检出率为57.9%。

临床应用与阅片要点

  • 以肺动脉分支数目异常为线索时,应系统扫查3VT、3支肺动脉分支及无名动脉冠状切面。
  • STIC-HD live flow超声可辅助显示与肺动脉分支异常相关的血管连接。
  • 识别1支、3支或4支肺动脉分支特征有助于系统评估以肺动脉分支异常为主要特征的胎儿心脏缺陷。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Assess prenatal ultrasound's diagnostic value in fetal cardiac anomalies using an abnormal number of pulmonary artery (PA) branches as an initial clue.

METHODS: Retrospective analysis of 20 fetuses with an abnormal number of PA branches on ultrasound, comparing prenatal ultrasonic findings with postnatal echocardiography, computed tomography (CT), surgery, autopsy, and genetic tests. Summarized ultrasonographic characteristics and occurrence frequencies in 3-vessel trachea (3VT), 3-vessel PA branch, and innominate artery (INA) coronary section.

RESULTS: In total, abnormal PA branches included: 1 branch (15 cases: 7 pulmonary artery sling [PAS], 4 unilateral absence of pulmonary artery [UAPA], 4 anomalous origin of 1 pulmonary artery from ascending aorta [AOPA]); 3 branches (2 cases: 1 isolated left subclavian artery [ILSA], 1 isolated left innominate artery [ILINA], absent right ductus arteriosus); 4 branches (3 cases: 2 ILSA, 1 ILINA, double ductus arteriosus). Associated anomalies: tetralogy of Fallot, persistent left superior vena cava, ventricular septal defect, Berry syndrome, and nasal bone dysplasia. Postnatal confirmations were achieved via autopsy (9 cases), imaging/surgery (10 cases), or lost (1 case). Genetic tests (14 cases) were normal. Detection: 63.2% (3VT section), 100% (3-vessel PA branch section), 57.9% (INA coronary section).

CONCLUSION: The 3VT, 3-vessel PA branch, and INA coronary section are key for the diagnosis of fetal cardiac malformations with abnormal PA branches. The spatiotemporal image correlation with high-definition (STIC-HD) live flow sonography can aid in visualizing the vascular connection linked to these anomalies. Identifying features of 1/3/4 PA branches facilitates a systematic assessment of fetal cardiac defects primarily characterized by aberrant PA branching.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Yang L, Yang Z, Zhou X, et al. Prenatal Diagnosis of Fetal Heart Malformation With Abnormal Number of Pulmonary Artery Branches as the Initial Clue. J Ultrasound Med. 2025. PMID: 40964867. doi:10.1002/jum.70076

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。