高帧率超声心动图机械波分析:可行性、决定因素与正常范围

Mechanical Wave Analysis at High Frame-Rate Echocardiography: Feasibility, Determinants, and Normal Ranges.
PubMed 文献 · JACC Cardiovasc Imaging · 2025-08-27

研究在239名无症状社区人群及心脏病理患者中评估高帧率超声心动图机械波(MW)测量的可行性、决定因素与正常范围。手动测量可行性在80%左右,MW速度与临床及超声心动图血流动力学/心功能指标关联很小或无关联。在66名无明确心血管疾病者中报告了各切面MW速度的正常值,但正常范围较宽;MW速度在亚临床功能障碍者中似乎并不异常。

要点

  • 高帧率超声心动图可测量心房收缩(AK)、主动脉瓣关闭(AVC)和二尖瓣关闭(MVC)机械波速度。
  • 手动测量可行性高于自动测量;A4C与PLAX的MVC信号一致性差,尤其在高速度测量时。
  • MW速度与血流动力学及心功能指标关联很小或无关联,正常范围宽,亚临床功能障碍者似乎不异常。

核心结论

  • MW测量(尤其AK)是标准超声心动图的可行辅助手段,但正常范围宽,即使在其它检查正常者中亦如此;MW速度在亚临床功能障碍中似乎不异常。

研究设计与样本

  • 研究纳入239名参与者(无症状者来自社区心衰监测项目,并包括心脏病理患者),行临床评估、6分钟步行试验及专用高帧率超声心动图;从胸骨旁长轴(PLAX)和心尖四腔(A4C)切面获取AK、AVC、MVC的MW信号,取3个周期自动与手动测量均值并剔除离群值(AVC>9 m/s、MVC>9 m/s、AK>7 m/s),据超声心动图及临床参数分为正常与异常组。

诊断标准与关键数值

  • 手动测量可行性:PLAX切面AK 80%、AVC 77%、MVC 77%;A4C切面AK 91%、AVC 85%、MVC 62%;手动测量可行性高于自动测量。66名无明确CVD者PLAX切面AVC、MVC、AK速度分别为3.91±1.82 m/s、3.58±1.67 m/s、1.77±1.10 m/s,A4C切面分别为4.09±1.54 m/s、5.63±1.61 m/s、1.24±0.38 m/s。103名无症状亚临床功能障碍者上述值总体略高;仅AK测量在超声心动图正常与异常患者间有显著差异。观察者内与观察者间偏倚小,但所有测量的一致性界限宽。

临床应用与阅片要点

  • MW测量(尤其AK)可作为标准超声心动图的可行辅助手段;由于正常范围宽且A4C与PLAX的MVC信号一致性差(尤其高速度测量时),解读MW速度需结合切面与测量方法。

局限性

  • 正常范围宽,即使在其它检查正常的参与者中亦如此。
  • A4C与PLAX的MVC信号一致性差,尤其在高速度测量时。
  • 所有测量的一致性界限宽。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: High-frame rate echocardiography can identify naturally occurring mechanical waves (MWs). As the velocity of MWs is related to tissue properties, this methodology could solve a fundamental shortcoming of echocardiography. However, to be useful clinically, there would need to be limited overlap between the normal range of MWs and measurements associated with pathology such as left ventricular dysfunction and ischemic heart disease.

OBJECTIVES: This study aims to evaluate the feasibility, key determinants, and normal ranges of MWs in asymptomatic people and in patients with cardiac pathology.

METHODS: Asymptomatic participants were recruited from a community-based heart failure surveillance program. Clinical evaluation, 6-minute walk test, and echocardiography with specialized high-frame rate imaging were performed. MW signals from atrial kick (AK), aortic valve closure (AVC), and mitral valve closure (MVC) were acquired from parasternal long-axis (PLAX) and apical 4-chamber (A4C) windows. Measurements were averaged across 3 cycles using automated and manual methods, and outliers were removed (AVC >9 m/s, MVC >9 m/s, and AK >7 m/s). Participants were classified into normal and abnormal groups on the basis of echocardiographic and clinical parameters.

RESULTS: Of the 239 participants, manual measurement was feasible in 80% for AK, 77% for AVC, and 77% for MVC MWs in the PLAX view and in 91%, 85%, and 62% in the A4C view. Manual measurements were more feasible than automated measurements. Clinical and echocardiographic markers of hemodynamic status and cardiac function had little or no association with MW velocities. Poor agreement was noted between A4C and PLAX MVC signals, especially with high-velocity measurements. In 66 participants without overt CVD, MW velocities in the PLAX view for AVC, MVC, and AK were 3.91 ± 1.82 m/s, 3.58 ± 1.67 m/s, and 1.77 ± 1.10 m/s. In the A4C view, these were 4.09 ± 1.54 m/s, 5.63 ± 1.61 m/s, and 1.24 ± 0.38 m/s, respectively. These values were generally slightly higher in 103 asymptomatic people with subclinical dysfunction. Only AK measurements were significantly different between patients with normal and abnormal findings on echocardiography. There was little bias within and between observers, but limits of agreement were wide for all measures.

CONCLUSIONS: MW measurement, especially AK, is a feasible adjunct to standard echocardiography. However, the normal ranges are wide, even among participants with otherwise normal studies. MW velocities do not seem to be abnormal in subclinical dysfunction.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。