冠状动脉CT血管造影衍生的血流储备分数(FFRCT)下降斜率作为识别未来急性冠脉综合征肇事病变前体的新型生物标志物
研究纳入428例随访3年的患者,53例发生ACS并与53例对照匹配,比较53个肇事病变前体与228个非肇事病变的FFRCT斜率及病变特异性FFRCT;肇事病变前体FFRCT斜率(-0.03±0.03 vs -0.01±0.01)和病变特异性FFRCT(0.71±0.11 vs 0.83±0.10)均较低,FFRCT斜率对肇事病变前体有较好判别价值,且斜率增大时3年内成为肇事病变的风险显著降低(OR=0.27,95%CI:0.17,0.72,P<0.01)。
要点
- 肇事病变前体的FFRCT斜率较非肇事病变更低(-0.03±0.03 vs -0.01±0.01,P<0.05)。
- 肇事病变前体病变特异性FFRCT较非肇事病变更低(0.71±0.11 vs 0.83±0.10,P<0.05)。
- FFRCT斜率增大时3年内成为肇事病变的风险显著降低(OR=0.27,95%CI:0.17,0.72,P<0.01)。
核心结论
- 肇事病变前体的FFRCT显著下降,FFRCT斜率与未来肇事病变相关,对肇事病变前体有较好判别价值;低FFRCT斜率的病变未来成为肇事病变的风险增加,应予以关注。
研究设计与样本
- 研究纳入428例随访3年的患者,其中53例发生ACS并与53例对照匹配,基于基线CCTA测量肇事病变前体(53个)和非肇事病变(228个)的形态学参数、FFRCT斜率和病变特异性FFRCT。
诊断标准与关键数值
- 肇事病变前体FFRCT斜率为-0.03±0.03,非肇事病变为-0.01±0.01(P<0.05);肇事病变前体病变特异性FFRCT为0.71±0.11,非肇事病变为0.83±0.10(P<0.05)。
临床应用与阅片要点
- FFRCT斜率对肇事病变前体有较好判别价值,低FFRCT斜率的病变未来成为肇事病变的风险增加,应予以关注。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Culprit lesion precursors are vulnerable and prone to rupture, leading to myocardial ischaemia. The aim of this study was to assess the value of coronary computed tomography angiography (CCTA)-derived fractional flow reserve (FFRCT) decreasing slope through plaques to identify culprit lesion precursors.
MATERIALS AND METHODS: We studied 428 patients tracked for acute coronary syndrome (ACS) over 3 years. Fifty-three developed ACS and were matched to 53 controls. Using baseline computed tomography (CT) angiography (CCTA) scans, we measured culprit lesion precursors and non-culprit lesions, assessing their morphological parameters, FFRCT slope, and lesion-specific FFRCT.
RESULTS: Fifty-three culprit lesion precursors and 228 non-culprit lesions were compared. Culprit lesion precursors exhibited lower FFRCT slope (-0.03 ± 0.03 vs -0.01 ± 0.01, P<0.05) and lesion-specific FFRCT (0.71 ± 0.11 vs 0.83 ± 0.10, P<0.05) compared with non-culprit lesions. FFRCT slopes of culprit lesion precursors varied according to the presence of plaque type, which was not obvious in non-culprit lesions. FFRCT slope showed a better discriminatory value for future culprit lesions. In the multivariable analysis, FFRCT slope and lesion-specific FFRCT were associated with future culprit lesions. The risk of becoming a future culprit lesion within 3 years was significantly decreased with the increasing of FFRCT slope (odds ratio [OR] = 0.27, 95% confidence interval [CI]: 0.17, 0.72, P<0.01).
CONCLUSION: FFRCT declines significantly in culprit lesion precursors, and FFRCT slope is associated with future culprit lesions. FFRCT slope has a better value for discriminating culprit lesion precursors. Lesions with low FFRCT slopes have an increased risk of becoming future culprit, and care should be taken for those lesions.
引用
- Dai X, Jiang Y, Fang K, et al. Coronary computed tomography angiography-derived fractional flow reserve (FFRCT) decreasing slope as a novel biomarker to identify culprit lesion precursors causing future acute coronary syndrome. Clin Radiol. 2025. PMID: 40961861. doi:10.1016/j.crad.2025.107047
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。