文献速递心血管CTMR

光子计数探测器与能量积分探测器双源CT双能量心肌细胞外容积定量:与心脏磁共振比较

Dual-energy based myocardial extracellular volume quantification with photon-counting detector and energy-integrating detector dual-source computed tomography: comparison with cardiac magnetic resonance.
PubMed 文献 · Eur Radiol · 2025-09-03

本研究以心脏磁共振为参考,比较单期与双期光子计数探测器CT及双期能量积分探测器CT对三维心肌细胞外容积(ECV)的定量。回顾性纳入80例同时接受CMR和心脏CT的患者(PCD-CT 40例,EID-CT 40例)。PCD-CT单期和双期ECV与CMR相关性和一致性均优于EID-CT(相关系数0.84、0.91 vs 0.62;ICC 0.90、0.94 vs 0.76,均p<0.05),PCD-CT两种方法间无显著差异(均p>0.05);EID-CT在心率>60 bpm时一致性降低(ICC 0.60 vs 0.78)。

要点

  • PCD-CT单期和双期ECV与CMR相关性和一致性均显著优于EID-CT(均p<0.05)。
  • PCD-CT单期与双期方法间无显著差异(均p>0.05),单期可达到与双期等效的性能。
  • EID-CT在心率>60 bpm时一致性降低(ICC 0.60),而PCD-CT在高心率下仍保持较高一致性(ICC 0.87–0.88)。

核心结论

  • 与EID-CT相比,PCD-CT在心肌ECV定量中表现出更优的相关性和可靠性,尤其在高心率患者中;PCD-CT单期方法的性能与双期方法等效。

研究设计与样本

  • 回顾性研究,纳入80例同时接受CMR和心脏CT的患者,其中40例行PCD-CT、40例行EID-CT;以CMR为参考标准,采用Pearson相关系数和组内相关系数(ICC)评估CT-ECV与CMR-ECV的相关性和可靠性,并按心率进行亚组分析。

诊断标准与关键数值

  • PCD-CT单期ECV与CMR的相关系数0.84,ICC 0.90;双期ECV与CMR的相关系数0.91,ICC 0.94。
  • EID-CT的ECV与CMR的相关系数0.62,ICC 0.76;PCD-CT两种方法均显著优于EID-CT(均p<0.05)。
  • PCD-CT单期与双期方法间无显著差异(均p>0.05)。
  • PCD-CT在心率≤60 bpm亚组ICC:单期0.89、双期0.85;心率>60 bpm亚组ICC:单期0.87、双期0.88。
  • EID-CT在心率≤60 bpm亚组ICC 0.78,心率>60 bpm亚组ICC 0.60。

临床应用与阅片要点

  • 作者认为PCD-CT作为心肌ECV评估的CMR替代方法具有前景,尤其在较高心率等挑战性条件下可提供更优的可靠性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study compared three-dimensional myocardial extracellular volume (ECV) quantification among single-phase and dual-phase photon-counting detector computed tomography (PCD-CT) and dual-phase energy-integrating detector computed tomography (EID-CT), using cardiac magnetic resonance (CMR) imaging as the reference.

MATERIALS AND METHODS: This retrospective study included 80 patients who underwent both CMR and cardiac CT (40 patients underwent PCD-CT and 40 underwent EID-CT). Pearson correlation coefficients and intraclass correlation coefficients (ICCs) were used to evaluate the correlation and reliability of CT-ECV with CMR-ECV. Subgroup analysis was performed based on heart rate.

RESULTS: The single-phase and dual-phase ECV measurements on PCD-CT showed excellent correlation and consistency with CMR (correlation coefficient: single-phase, 0.84; dual-phase, 0.91; ICC: single-phase, 0.90; dual-phase, 0.94). Both methods significantly outperformed EID-CT (correlation coefficient: 0.62; ICC: 0.76; all p < 0.05). No significant differences were observed between the two PCD-CT methods (all p > 0.05). PCD-CT demonstrated high consistency across both HR subgroups (ICC: HR ≤ 60 bpm: 0.89 for single-phase, 0.85 for dual-phase; HR > 60 bpm: 0.87 for single-phase, 0.88 for dual-phase), whereas EID-CT exhibited reduced consistency in patients with HR > 60 bpm (ICC: HR ≤ 60 bpm: 0.78; HR > 60 bpm: 0.60).

CONCLUSION: Compared with EID-CT, PCD-CT showed superior correlation and reliability for myocardial ECV quantification, particularly in patients with elevated heart rates. The single-phase PCD-CT method demonstrated performance equivalent to the dual-phase approach.

KEY POINTS: Question How does myocardial ECV quantification using PCD-CT compare with conventional EID-CT? Findings Single-phase and dual-phase methods on PCD-CT significantly outperform EID-CT in myocardial ECV quantification. Clinical relevance These findings suggest PCD-CT significantly outperforms EID-CT as a promising alternative to CMR for myocardial ECV assessment, particularly under challenging conditions such as higher heart rates, offering improved reliability for clinical myocardial tissue characterization.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bao S, Zhou M, Wang M, et al. Dual-energy based myocardial extracellular volume quantification with photon-counting detector and energy-integrating detector dual-source computed tomography: comparison with cardiac magnetic resonance. Eur Radiol. 2025. PMID: 40903622. doi:10.1007/s00330-025-11942-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。