文献速递儿科影像心血管US

法洛四联症胎儿升主动脉血流模式异常:血斑点追踪超声心动图评估

Abnormal flow patterns in ascending aorta in fetuses with tetralogy of Fallot: evaluation by blood speckle-tracking echocardiography.
PubMed 文献 · Ultrasound Obstet Gynecol · 2025-09-27

采用高帧率超声血斑点追踪超声心动图评估35例法洛四联症胎儿与35例孕龄匹配正常胎儿的升主动脉血流模式。法洛四联症胎儿升主动脉涡流检出率91.4%(32/35)高于正常胎儿17.1%(6/35)(P<0.001),涡流数量中位数1(范围0-3)高于正常胎儿0(范围0-1)(P<0.001),左心室流入流出道夹角中位数36.06°小于正常胎儿42.90°(P=0.006)。涡流存在与主动脉瓣尺寸(r=0.54,P=0.001)及左心室流入流出道夹角(r=-0.376,P=0.026)相关。

要点

  • 法洛四联症胎儿升主动脉涡流检出率91.4%(32/35),正常胎儿17.1%(6/35),P<0.001。
  • 法洛四联症胎儿升主动脉涡流数量中位数1(范围0-3)高于正常胎儿0(范围0-1),P<0.001。
  • 法洛四联症胎儿左心室流入流出道夹角中位数36.06°小于正常胎儿42.90°,P=0.006。

核心结论

  • 血斑点追踪超声心动图显示法洛四联症胎儿升主动脉血流涡流发生率更高、数量更多,且与左心室流出道形态及心脏几何构型相关,可能有助于阐明法洛四联症胎儿主动脉病理生理。

研究设计与样本

  • 横断面研究,纳入2022年4月至2023年8月间35例法洛四联症胎儿和35例孕龄匹配的正常胎儿(对照组),均行常规产科超声检查和完整超声心动图,采用高帧率超声血斑点追踪超声心动图记录并评估升主动脉血流模式,测量两组左心室流入流出道夹角。

关键影像表现/征象

  • 血斑点追踪超声心动图显示法洛四联症胎儿升主动脉内检出涡流者占91.4%(32/35),正常胎儿占17.1%(6/35),P<0.001。
  • 法洛四联症胎儿升主动脉涡流数量中位数为1(范围0-3),正常胎儿为0(范围0-1),P<0.001。
  • 两组涡流持续时间无显著差异。
  • 法洛四联症胎儿左心室流入流出道夹角中位数36.06°(四分位距32.55°-41.24°)小于正常胎儿42.90°(四分位距36.30°-46.37°),P=0.006。

诊断标准与关键数值

  • 法洛四联症胎儿升主动脉涡流检出率91.4%(32/35),正常胎儿17.1%(6/35),P<0.001。
  • 法洛四联症胎儿升主动脉涡流数量中位数1(范围0-3),正常胎儿0(范围0-1),P<0.001。
  • 法洛四联症胎儿左心室流入流出道夹角中位数36.06°(四分位距32.55°-41.24°),正常胎儿42.90°(四分位距36.30°-46.37°),P=0.006。
  • 法洛四联症胎儿中涡流存在与主动脉瓣尺寸相关(r=0.54,P=0.001),与左心室流入流出道夹角相关(r=-0.376,P=0.026)。
  • 法洛四联症胎儿中涡流数量与主动脉瓣尺寸相关(r=0.476,P=0.004),涡流存在及数量与肺动脉瓣尺寸无相关性。

临床应用与阅片要点

  • 采用血斑点追踪超声心动图可在胎儿期显示法洛四联症升主动脉涡流,表现为涡流检出率及数量高于孕龄匹配正常胎儿。
  • 法洛四联症胎儿升主动脉涡流存在及数量与主动脉瓣尺寸、左心室流入流出道夹角相关,与肺动脉瓣尺寸无相关性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the blood flow pattern in the ascending aorta (AAo) of fetuses with tetralogy of Fallot (ToF) using high-frame-rate ultrasound with blood speckle-tracking echocardiography (BST), and to investigate its relationship with cardiac geometry.

METHODS: Included in this cross-sectional study were 35 fetuses with ToF and 35 gestational-age-matched normal fetuses (controls) who underwent routine obstetric ultrasound examination and complete echocardiography between April 2022 and August 2023. Flow patterns in the AAo were recorded and assessed using BST in all fetuses. Left ventricular (LV) inflow and outflow tract angle (IOA) was measured in both groups. The association between the presence and number of vortices in the AAo and cardiac geometry in the ToF group was also determined.

RESULTS: On BST, at a median gestational age of 24.9 (interquartile range (IQR), 23.7-28.7) weeks for all fetuses, vortex flow in the AAo was detected in 91.4% (32/35) of fetuses with ToF and 17.1% (6/35) of normal fetuses (P < 0.001). Compared with the controls, the median number of vortices in the AAo was significantly higher in fetuses with ToF (1 (range, 0-3) vs 0 (range, 0-1); P < 0.001). There was no significant difference in vortex duration between the two groups. The fetuses with ToF exhibited significantly smaller median LV-IOA compared with the control fetuses (36.06° (IQR, 32.55°-41.24°) vs 42.90° (IQR, 36.30°-46.37°); P = 0.006). Correlation analysis indicated that the presence of vortices was associated significantly with aortic valve size in fetuses with ToF (r = 0.54 (P = 0.001)), as well as the LV-IOA (r = - 0.376 (P = 0.026)). The number of vortices correlated significantly with aortic valve size (r = 0.476 (P = 0.004)). There was no correlation between the presence and number of vortices and pulmonary valve size.

CONCLUSIONS: On BST, fetuses with ToF exhibited a higher incidence and a greater number of blood flow vortices in the AAo compared with gestational-age-matched controls. The association between the abnormal flow pattern in the AAo and LV outflow tract morphology, as well as cardiac geometry, may help to elucidate the pathophysiology of the aorta in fetuses with ToF. © 2025 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Zhou D, Liu Y, Xu G, et al. Abnormal flow patterns in ascending aorta in fetuses with tetralogy of Fallot: evaluation by blood speckle-tracking echocardiography. Ultrasound Obstet Gynecol. 2025. PMID: 41014168. doi:10.1002/uog.70029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。