光子计数CT测定冠状动脉斑块有效原子序数图像分析的适用性

Applicability of Effective Atomic Number (Zeff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography.
PubMed 文献 · Invest Radiol · 2025-09-22

本研究利用光子计数CT生成的虚拟单能图像推导有效原子序数(Zeff)图像,分析10例患者64个冠状动脉斑块的Zeff评分,并与传统Agatston评分和平均冠状动脉钙化评分比较。Zeff评分与两种传统评分均呈强正相关,且传统评分仅纳入CT值>130的体素而排除了39%的斑块面积,Zeff评分可分析全部斑块体素。研究表明Zeff成像技术可行,适用于反映整个斑块体积的分析。

要点

  • Zeff评分与Agatston评分及平均CAC评分均呈强正相关。
  • 传统钙化评分仅纳入CT值>130的体素,排除了39%的斑块面积。
  • Zeff评分利用斑块区域全部体素数据,可同时分析低密度和高密度斑块。

核心结论

  • Zeff成像可适用于反映整个斑块体积的斑块分析,本研究证明了其作为Zeff图像成分分析方法的技术可行性。

研究设计与样本

  • 研究论文;纳入10例患者共64个冠状动脉斑块;使用光子计数CT生成的虚拟单能图像,通过自研程序利用低能和高能线性衰减系数差值推导Zeff值;以传统Agatston评分和平均冠状动脉钙化评分为参照进行比较。

关键影像表现/征象

  • Zeff图像的系统不确定度估计为±0.08。
  • 实际患者数据的Zeff评分与传统Agatston评分及平均CAC评分均呈强正相关。
  • 传统评分仅考虑CT值>130的体素,排除了39%的斑块面积。
  • Zeff评分利用斑块区域全部体素数据,可分析低密度和高密度斑块。

诊断标准与关键数值

  • Zeff评分计算为斑块区域内Zeff值之和。
  • 传统Agatston评分和平均CAC评分仅纳入CT值>130的体素。
  • Zeff图像系统不确定度为±0.08。

临床应用与阅片要点

  • Zeff评分基于斑块区域全部体素,可弥补传统钙化评分排除低密度区域的不足。
  • Zeff图像系统不确定度为±0.08,阅片时需考虑该技术误差范围。

局限性

  • 本研究仅纳入10例患者64个斑块,样本量有限。
  • 本研究结论为技术可行性,原文指出其作为成分分析方法的技术可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Coronary computed tomography (CT) allows the assessment of cardiovascular risk by imaging calcified plaques in coronary arteries. Because photon-counting CT (PC-CT) can analyze the effective atomic number (Zeff) of the subject, it is expected to be applied to the analysis of plaque components. The purpose of this study was to investigate the applicability of plaque analysis based on Zeff images with continuous gradation.

METHODS: Zeff images were generated from virtual monoenergetic images (VMIs) obtained by PC-CT. Zeff values were derived from the difference between linear attenuation coefficients (μ) at low and high energies using an in-house program. Coronary CT images of 64 plaques in 10 patients were analyzed. The Zeff score, calculated as the sum of Zeff values within the plaque region, was calculated and compared with the conventional Agatston score and mean coronary artery calcium (CAC) score.

RESULTS: The systematic uncertainty of Zeff images was estimated to be ±0.08. The Zeff score of actual patient data showed strong positive correlations with the conventional Agatston and mean CAC scores. The Zeff score uses all voxel data in the plaque area, whereas conventional scores consider only data from voxels with a CT value >130. We found that the conventional scores excluded 39% of the plaque area, and the Zeff score permitted the analysis of low- and high-density plaques.

CONCLUSIONS: Zeff imaging was shown to be applicable to plaque analysis that reflects the entire plaque volume. This study demonstrated its technical feasibility as a compositional analysis method using the Zeff image.

来源:Invest Radiol,查看原文。版权归原作者所有。