猪模型光子计数CT心肌细胞外容积定量最佳增强后时间窗:以心脏磁共振为参考标准
本研究在梗死猪与健康对照中比较光子计数CT(PCCT)与心脏磁共振(CMR)衍生的心肌细胞外容积(ECV),于增强后3、5、7、9、12、15分钟采集PCCT。全节段r为0.79–0.91、ICC为0.88–0.95、AUC为0.799–0.847(均p<0.001),5分钟相关性及一致性最高(r=0.91;ICC=0.95,95%CI 0.92–0.96),3–7分钟形成较宽时间窗,心率>84 bpm时仍保持较好一致性(ICC=0.78–0.92)与诊断效能(AUC 0.677–0.777)。
要点
- 增强后3–7分钟为PCCT-ECV与CMR一致性较高的时间窗,5分钟达峰值(r=0.91;ICC=0.95)。
- 全节段PCCT-ECV鉴别LGE阳性与阴性节段的AUC为0.799–0.847(均p<0.001)。
- 心率>84 bpm时PCCT与CMR一致性ICC为0.78–0.92,AUC为0.677–0.777。
核心结论
- 在猪模型中,PCCT可在增强后3–7分钟准确、稳定地定量ECV并与CMR高度一致,提供较宽的临床扫描时间窗,且在不同心率下表现稳健。
研究设计与样本
- 临床前动物研究:对梗死猪行23次CMR与PCCT扫描、健康对照行9次扫描;PCCT于增强后3、5、7、9、12、15分钟采集,以CMR为参考标准。
关键影像表现/征象
- PCCT-ECV与CMR-ECV在全心肌节段、梗死心肌及正常心肌中均具相关性(r=0.79–0.91)与一致性(ICC=0.88–0.95)。
- 增强后5分钟相关性及一致性最高(r=0.91;ICC=0.95,95%CI 0.92–0.96),3分钟与7分钟亦较高(r=0.90;ICC分别为0.93与0.94),其后逐渐下降。
- 心率>84 bpm时PCCT与CMR仍保持稳健一致性(ICC=0.78–0.92)及可接受的诊断效能(AUC 0.677–0.777)。
诊断标准与关键数值
- 以CMR为参考标准,PCCT-ECV鉴别LGE阳性与LGE阴性心肌节段的全节段AUC为0.799–0.847(均p<0.001)。
- PCCT与CMR-ECV的一致性以ICC评价:全节段ICC 0.88–0.95,5分钟最高(0.95,95%CI 0.92–0.96)。
- 相关性以Pearson r评价:全节段r 0.79–0.91,5分钟最高(r=0.91)。
临床应用与阅片要点
- 作者结论提示增强后3–7分钟为PCCT-ECV与CMR一致性较高的采集时间窗,可供临床扫描方案参考。
- 心率>84 bpm时PCCT-ECV与CMR一致性ICC为0.78–0.92、AUC为0.677–0.777,提示该方法在高心率下仍具稳健性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Advances in computed tomography (CT) have enabled myocardial extracellular volume (ECV) quantification, but the optimal post-contrast timing for CT-derived ECV remains undefined. In this preclinical study using a swine model, we aimed to determine the optimal post-contrast acquisition time for photon-counting CT (PCCT)-derived ECV using cardiac magnetic resonance (CMR) as the reference standard.
MATERIALS AND METHODS: Twenty-three CMR and PCCT scans were performed on infarcted swine, and nine scans on healthy controls. PCCT scans were acquired at 3-, 5-, 7-, 9-, 12-, and 15-minutes after contrast administration. Pearson correlation coefficients (r) and intraclass correlation coefficients (ICCs) were calculated between PCCT- and CMR-derived ECV across all myocardial segments, infarcted and normal myocardium. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of PCCT-ECV in differentiating LGE-positive from LGE-negative myocardial segments. Subgroup analyses were conducted based on heart rate (HR).
RESULTS: Across all segments, r ranged from 0.79 to 0.91 and ICCs from 0.88 to 0.95 and the area under the ROC curve (AUC) values ranged from 0.799 to 0.847 (all p < 0.001). Peak correlation and agreement occurred at 5 min (r = 0.91; ICC = 0.95, 95 % CI: 0.92-0.96), with similarly high values at 3 and 7 min (r = 0.90; ICC = 0.93 and 0.94, respectively), followed by a gradual decline. At elevated HRs (>84 bpm), PCCT still maintained robust agreement with CMR (ICC = 0.78-0.92) and satisfactory diagnostic performance (AUC values ranged from 0.677 to 0.777).
CONCLUSION: PCCT enables accurate and consistent ECV quantification with strong concordance to CMR from 3 to 7 min post-contrast in swine models, providing a wide temporal window for clinical scanning. This was further confirmed by ROC analysis, and the method demonstrated robustness across varying heart rates.
引用
- Bao S, Yang M, Liu P, et al. Optimal post-contrast timing for photon-counting CT-based myocardial extracellular volume quantification in a swine model: Cardiac magnetic resonance as the reference. Eur J Radiol. 2025. PMID: 40886490. doi:10.1016/j.ejrad.2025.112383
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。