文献速递心血管MRUS

高血压早期舒张功能障碍检测:CMR衍生的左心房应变

Early Diastolic Dysfunction Detection in Hypertension: CMR-Derived Left Atrial Strain.
PubMed 文献 · Acad Radiol · 2025-09-04

回顾性纳入150例高血压患者与60例健康对照,均行超声心动图和CMR检查,用CMR特征追踪量化左心房应变。高血压患者储器应变和管道应变受损并随左室舒张功能障碍严重程度加重,εs<29.3%为检测舒张功能障碍的最佳单一指标(平均AUC 0.856),联合常规超声舒张指标、εs和左房容积的多变量模型平均AUC达0.929。

要点

  • 高血压患者CMR左房储器应变εs和管道应变εe较健康对照受损,且随舒张功能障碍分级加重而进展。
  • εs<29.3%检测高血压患者左室舒张功能障碍的平均AUC为0.856、敏感度0.859、特异度0.851。
  • 联合常规超声舒张指标、εs与左房容积的多变量模型平均AUC 0.929,优于单一εs指标。

核心结论

  • CMR衍生的左心房应变参数可作为检测高血压患者左室舒张功能障碍的敏感早期标志物,随舒张功能障碍严重程度逐渐恶化,并对舒张功能障碍诊断提供增量价值。

研究设计与样本

  • 回顾性纳入150例高血压患者和60例健康对照,均接受超声心动图和CMR检查,高血压患者按现行指南的左室舒张功能障碍严重程度分层,采用CMR特征追踪量化左房储器、管道和助力泵应变。

关键影像表现/征象

  • 与健康对照相比,高血压患者储器应变(εs)和管道应变(εe)受损,并随左室舒张功能障碍严重程度增加而进行性恶化。
  • εs在各左室舒张功能障碍亚型间差异均有统计学意义(均p<0.05)。
  • 助力泵应变(εa)在早期高血压中保持或轻度升高,在晚期左室舒张功能障碍中下降。

诊断标准与关键数值

  • εs<29.3%(95%CI 27.8%-31.3%)为检测高血压患者左室舒张功能障碍的最佳单一指标,平均AUC 0.856(95%CI 0.706-0.968),敏感度0.859(95%CI 0.667-1.000),特异度0.851(95%CI 0.682-0.964)。
  • 联合常规超声舒张指标、εs和左房容积的多变量诊断模型平均AUC 0.929(95%CI 0.824-0.994),敏感度0.887(95%CI 0.692-1.000),特异度0.927(95%CI 0.792-1.000)。
  • 高血压患者按现行指南的左室舒张功能障碍严重程度进行分层。

临床应用与阅片要点

  • 左房应变和应变率参数与常规超声舒张指标呈稳健相关,可在报告中作为舒张功能评估的补充量化指标。
  • εa在早期高血压中保持或轻度升高、在晚期左室舒张功能障碍中下降,判读时应结合舒张功能障碍分期理解其变化方向。

局限性

  • 本研究为回顾性纳入。
  • 采用Bootstrap重采样(1000次迭代)进行内部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: This study aimed to investigate the role of cardiac magnetic resonance (CMR)-derived left atrial (LA) strain parameters in evaluating early cardiac dysfunction in hypertensive patients and to assess their diagnostic utility for left ventricular diastolic dysfunction (LVDD).

METHODS: A total of 150 hypertensive patients and 60 healthy controls were retrospectively enrolled, with all participants undergoing both echocardiographic and CMR examinations. Hypertensive patients were stratified by LVDD severity based on current guidelines. CMR feature-tracking (CMR-FT) was utilized to quantify LA strain, including reservoir, conduit, and booster pump functions. Intergroup comparisons of functional parameters and LA strain profiles were performed, alongside correlation analysis with conventional echocardiographic diastolic markers. Receiver operating characteristic (ROC) analysis was performed to evaluate the utility of LA strain for detecting LVDD in hypertensive patients, and a multivariable diagnostic model incorporating additional parameters was established. Bootstrap resampling (1000 iterations) was used for internal validation.

RESULTS: Compared with healthy controls, hypertensive patients exhibited impaired reservoir (εs) and conduit (εe) strains, which worsened progressively with increasing LVDD severity. εs showed significant differences across all LVDD subtypes (all p<0.05). Booster pump strain (εa) remained preserved or mildly elevated in early-stage hypertension, yet declined in advanced LVDD. LA strain and strain rate parameters demonstrated robust correlations with conventional diastolic indices. ROC analysis identified εs < 29.3% (95% confidence interval [CI]: 27.8%-31.3%) as the optimal single indicator for detecting LVDD in hypertensive patients, with a mean area under the curve (AUC) of 0.856 (95%CI: 0.706-0.968), sensitivity of 0.859 (95%CI: 0.667-1.000), specificity of 0.851 (95%CI: 0.682-0.964). The multivariable diagnostic model, which integrated conventional echocardiographic diastolic markers, εs, and LA volume, exhibited superior performance, with a mean AUC of 0.929 (95%CI: 0.824-0.994), sensitivity of 0.887 (95%CI: 0.692-1.000), and specificity of 0.927 (95%CI: 0.792-1.000).

CONCLUSION: CMR-derived LA strain parameters served as sensitive early markers for detecting LVDD in hypertension. They progressively deteriorate with the diastolic dysfunction severity and provide incremental value for LVDD diagnosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liao W, Fang B, Kang Y, et al. Early Diastolic Dysfunction Detection in Hypertension: CMR-Derived Left Atrial Strain. Acad Radiol. 2025. PMID: 40912951. doi:10.1016/j.acra.2025.08.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。