心脏CT检测左心耳封堵装置后左心耳通畅性的结局:一项Meta分析
该Meta分析纳入17项研究共2036例患者,评估心脏CT检测的左心耳封堵后左心耳通畅及装置周漏与血栓栓塞风险的关联;左心耳通畅与血栓栓塞风险约2倍增加相关(汇总OR 1.87,95%CI 1.08-3.24),装置周漏呈相似趋势但未达统计学显著(汇总OR 1.50,95%CI 0.85-2.65);作者认为CT检测的残余漏可能有临床意义,不应视为良性。
要点
- 心脏CT检测的左心耳通畅与血栓栓塞风险约2倍增加相关(汇总OR 1.87,95%CI 1.08-3.24)。
- 装置周漏与血栓栓塞风险呈相似趋势但未达统计学显著(汇总OR 1.50,95%CI 0.85-2.65)。
- 作者认为CT检测的残余漏可能有临床意义,不应视为良性。
核心结论
- 心脏CT识别的左心耳通畅和装置周漏可能与血栓栓塞风险增加相关,残余漏可能有临床意义,不应视为良性。
研究设计与样本
- 研究类型为Meta分析,纳入17项研究共2036例患者,采用传统Meta分析方法及贝叶斯框架评估残余漏相关风险概率。
关键影像表现/征象
- 心脏CT检测的任何左心耳通畅与血栓栓塞风险增加相关(汇总OR 1.87,95%CI 1.08-3.24),相当于每1000例患者增加28例事件(95%CI 3-68)。
- 装置周漏与血栓栓塞风险呈相似趋势但未达统计学显著(汇总OR 1.50,95%CI 0.85-2.65)。
- 贝叶斯框架下,左心耳通畅的平均logOR为0.59(95%可信区间0.06-1.15),中位OR 1.87(95%可信区间1.06-3.14),平均绝对风险差2.8%(95%可信区间0.2%-6.8%),绝对风险差>0%的后验概率为98.5%。
- 任何装置周漏的平均logOR为0.38(95%可信区间-0.22至0.95),中位OR 1.53(95%可信区间0.80-2.59),平均绝对风险差1.9%(95%可信区间-0.7%至5.4%),绝对风险差>0%的后验概率为89.8%。
诊断标准与关键数值
- 左心耳通畅与血栓栓塞风险的汇总OR为1.87(95%CI 1.08-3.24),相当于每1000例患者增加28例事件(95%CI 3-68)。
- 装置周漏与血栓栓塞风险的汇总OR为1.50(95%CI 0.85-2.65),未达统计学显著。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Residual leaks are common after left atrial appendage occlusion (LAAO).
OBJECTIVES: The authors aimed to systematically evaluate the prognostic implications of residual left atrial appendage (LAA) patency and peridevice leaks (PDLs) detected by cardiac computed tomography (CT) following LAAO.
METHODS: The authors used traditional meta-analytical methods and a Bayesian framework to assess the probability of increased risks associated with these residual leaks.
RESULTS: Seventeen studies encompassing 2,036 patients met the inclusion criteria. During follow-up, the presence of any LAA patency was significantly associated with an almost 2-fold increased OR of thromboembolism (pooled OR: 1.87, 95% CI: 1.08-3.24), corresponding to 28 (95% CI: 3-68) additional events per 1,000 patients. Although PDL showed a similar trend, it was not significantly associated with increased thromboembolism risk (pooled OR: 1.50, 95% CI: 0.85-2.65). For thromboembolism with LAA patency, under a noninformative prior, the mean logOR was 0.59 (95% credible interval [Crl]: 0.06-1.15), and translated median OR of 1.87 (95% CrI: 1.06-3.14) and a mean absolute risk difference (ARD) of 2.8% (95% CrI: 0.2%-6.8%). The posterior probability of ARD >0% was 98.5%. For any PDL, the mean logOR was 0.38 (95% CrI: -0.22 to 0.95), with a median OR of 1.53 (95% CrI: 0.80-2.59) and mean ARD of 1.9% (95% CrI: -0.7% to 5.4%). The posterior probability of ARD >0% was 89.8%.
CONCLUSIONS: LAA patency and PDL identified by CT may be associated with an increased risk of thromboembolism. These findings indicate that residual leaks detected by CT may be clinically significant and should not be regarded as benign.
引用
- Jacquemyn X, Sá MP, Korsholm K, et al. Outcomes of Left Atrial Appendage Patency After Device Closure Detected by Cardiac CT: A Meta-Analysis. JACC Cardiovasc Imaging. 2025. PMID: 40923950. doi:10.1016/j.jcmg.2025.07.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。