基于深度学习的屏气与自由呼吸电影MRI用于全面心脏评估
该前瞻性研究纳入70名受试者(含心律失常24例、呼吸困难17例、正常窦性心律且呼吸平稳29例),在3T扫描仪上比较标准电影MRI、屏气深度学习(BHDL)和自由呼吸深度学习(FBDL)序列的扫描时间、测量准确性和图像质量。结果显示BHDL与FBDL均显著缩短总检查时间且定量测量准确性与标准电影MRI无统计学显著差异,BHDL测量一致性更优且适用于心律失常患者,FBDL对呼吸困难患者图像质量更佳。
要点
- BHDL与FBDL较标准电影MRI显著缩短总检查时间,且定量测量准确性与标准序列无统计学显著差异。
- BHDL测量一致性优于FBDL,左、右心室射血分数的95%一致性界限更窄。
- 心律失常患者中BHDL图像质量Likert评分显著高于标准电影MRI和FBDL;呼吸困难患者中FBDL图像质量评分最高。
核心结论
- BHDL与FBDL均显著缩短扫描时间且不损害定量测量准确性;BHDL测量准确性更优、扫描时间更短,对心律失常患者可减少心律失常相关伪影,FBDL对呼吸困难患者可减轻呼吸运动伪影。
研究设计与样本
- 前瞻性研究,纳入70名受试者(心律失常24例、呼吸困难17例、正常窦性心律且呼吸平稳29例,平均年龄49±17岁),在3T扫描仪上每人行标准电影MRI、BHDL和FBDL三种序列采集,由三名放射科医师独立盲法进行双心室功能、左心室质量和心肌应变定量评估及图像质量评价。
关键影像表现/征象
- BHDL与FBDL的定量测量结果与标准电影MRI相比无统计学显著差异,且相关系数>0.85。
- BHDL在所有参数上的95%一致性界限均窄于FBDL。
- 心律失常患者中BHDL图像质量Likert评分为4.44±0.56,高于标准电影MRI的4.00±0.99(校正P=0.043)和FBDL的3.94±0.56(校正P=0.030)。
- 呼吸困难患者中FBDL图像质量评分最高为4.24±0.47,高于标准电影MRI的3.41±0.97(校正P=0.028)和BHDL的3.68±0.56(校正P=0.028)。
诊断标准与关键数值
- BHDL左心室射血分数95%一致性界限为-3.5%至3.9%,右心室射血分数为-3.4%至4.0%。
- FBDL左心室射血分数95%一致性界限为-4.6%至5.8%,右心室射血分数为-7.8%至9.3%。
- 图像质量采用五点Likert量表评价。
临床应用与阅片要点
- 心律失常患者选用BHDL序列可减少心律失常相关伪影并获得更高图像质量评分。
- 呼吸困难患者选用FBDL序列可减轻呼吸运动伪影并获得最高图像质量评分。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate and compare scan times, measurement accuracy, and image quality (IQ) of free-breathing (FB) and breath-hold (BH) deep learning (DL) cine MRI sequences versus standard cine MRI, with a specific focus on patients with arrhythmia and dyspnea.
MATERIALS AND METHODS: Seventy participants were prospectively enrolled, including 24 with arrhythmia, 17 with dyspnea, and 29 with normal sinus rhythm and eupnea (mean age, 49 ± 17 years). Each patient underwent three cine MRI acquisitions (standard cine, BHDL, and FBDL) on a 3T scanner. Quantitative assessments of biventricular function, left ventricular mass, and myocardial strain were independently performed by three radiologists, blinded to image acquisition techniques. IQ was evaluated by the same readers using both a five-point Likert scale and objective metrics.
RESULTS: Both BHDL and FBDL significantly reduced total examination times compared to standard cine (BHDL: 58 ± 5 s; FBDL: 88 ± 12 s; standard cine: 208 ± 12 s; adjusted P < 0.001). Quantitative measurements from BHDL and FBDL showed no statistically significant differences compared to standard cine and showed strong correlations (correlation coefficients > 0.85) with standard cine. BHDL consistently demonstrated narrower 95% limits of agreement (LOA) than FBDL across all parameters. For BHDL, the 95% LOA for left and right ventricular ejection fractions were -3.5% to 3.9% and -3.4% to 4.0%, respectively; for FBDL, they were -4.6% to 5.8% and -7.8% to 9.3%, respectively. In patients with arrhythmia, BHDL achieved significantly higher IQ Likert scores (4.44 ± 0.56) than both standard cine (4.00 ± 0.99; adjusted P = 0.043) and FBDL (3.94 ± 0.56; adjusted P = 0.030). In patients with dyspnea, FBDL received the highest IQ scores (4.24 ± 0.47), outperforming standard cine (3.41 ± 0.97; adjusted P = 0.028) and BHDL (3.68 ± 0.56; adjusted P = 0.028).
CONCLUSION: Both FBDL and BHDL significantly reduced scan times compared to standard cine without compromising quantitative measurement accuracy. BHDL offered superior measurement accuracy and shorter scan time than FBDL. Furthermore, BHDL demonstrated robust suitability for patients with arrhythmia by minimizing arrhythmia-related artifacts, whereas FBDL was more effective in patients with dyspnea by mitigating respiratory motion artifacts.
引用
- Wu Y, Sun W, Wang S, et al. Deep Learning-Based Breath-Hold and Free-Breathing Cine MRI for Comprehensive Cardiac Evaluation. Korean J Radiol. 2025. PMID: 41015857. doi:10.3348/kjr.2025.0440
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。