文献速递胸部外周血管技术与安全CT

人工智能分诊对放射科医生报告周转时间的影响:真实世界时间节省与模型预测的洞察

Impact of Artificial Intelligence Triage on Radiologist Report Turnaround Time: Real-World Time Savings and Insights From Model Predictions.
PubMed 文献 · J Am Coll Radiol · 2025-09-29

本回顾性研究分析了单中心11252例因疑似肺栓塞行胸部CT肺动脉造影的成人检查,比较人工智能分诊部署前后的报告周转时间。结果显示工作时段肺栓塞阳性检查的周转时间从68.9分钟降至46.7分钟,时间节省22.2分钟(P=0.004),非工作时段节省2.82分钟(P=0.345)未达统计学显著;观察到的节省与计算模型预测一致。

要点

  • 工作时段肺栓塞阳性检查报告周转时间AI后较AI前缩短22.2分钟(P=0.004)。
  • 非工作时段周转时间节省2.82分钟,未达统计学显著(P=0.345)。
  • 模型预测的工作时段节省为29.6分钟,与临床观察到的节省方向一致。

核心结论

  • 人工智能分诊设备优先处理肺栓塞阳性胸部CT肺动脉造影检查,在工作时段可显著缩短报告周转时间,非工作时段未见显著缩短。
  • 考虑并量化临床工作流程有助于准确评估人工智能分诊部署后报告周转时间的预期节省。

研究设计与样本

  • 回顾性研究,分析单中心三级学术医疗中心11252例因疑似肺栓塞行胸部CT肺动脉造影的成人检查。
  • 数据分为人工智能部署前(4694例,肺栓塞阳性13.3%)和部署后(6558例,肺栓塞阳性16.2%)两个时期。
  • 从PACS检索527234条记录提取检查到达间隔时间和放射科医生阅读时间等工作流程参数,输入计算模型预测时间节省。
  • 参考标准为患者扫描完成至首份初步报告完成的时间间隔即周转时间。

诊断标准与关键数值

  • 人工智能部署前工作时段肺栓塞阳性检查平均周转时间为68.9分钟(95%CI 55.0-82.8),部署后为46.7分钟(95%CI 38.1-55.2)。
  • 人工智能部署前非工作时段平均周转时间为44.8分钟(95%CI 33.7-55.9),部署后为42.0分钟(95%CI 33.6-50.3)。
  • 工作时段临床观察到的周转时间节省为22.2分钟(95%CI 5.85-38.6),P=0.004。
  • 非工作时段临床观察到的节省为2.82分钟(95%CI -11.1至16.7),P=0.345。
  • 模型预测工作时段节省29.6分钟(95%范围23.2-38.1),非工作时段节省2.10分钟(95%范围1.76-2.58)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To quantify the impact of workflow parameters on time savings in report turnaround time due to an AI triage device that prioritized pulmonary embolism (PE) in chest CT pulmonary angiography (CTPA) examinations.

METHODS: This retrospective study analyzed 11,252 adult CTPA examinations conducted for suspected PE at a single tertiary academic medical center. Data was divided into two periods: pre-artificial intelligence (AI) and post-AI. For PE-positive examinations, turnaround time (TAT)-defined as the duration from patient scan completion to the first preliminary report completion-was compared between the two periods. Time savings were reported separately for work-hour and off-hour cohorts. To characterize radiologist workflow, 527,234 records were retrieved from the PACS and workflow parameters such as examination interarrival time and radiologist read time extracted. These parameters were input into a computational model to predict time savings after deployment of an AI triage device and to study the impact of workflow parameters.

RESULTS: The pre-AI dataset included 4,694 chest CTPA examinations with 13.3% being PE-positive. The post-AI dataset comprised 6,558 examinations with 16.2% being PE-positive. The mean TAT for pre-AI and post-AI during work hours are 68.9 (95% confidence interval 55.0-82.8) and 46.7 (38.1-55.2) min, respectively, and those during off-hours are 44.8 (33.7-55.9) and 42.0 (33.6-50.3) min. Clinically observed time savings during work hours (22.2 [95% confidence interval: 5.85-38.6] min) were significant (P = .004), while off-hour (2.82 [-11.1 to 16.7] min) were not (P = .345). Observed time savings aligned with model predictions (29.6 [95% range: 23.2-38.1] min for work hours; 2.10 [1.76, 2.58] min for off-hours).

DISCUSSION: Consideration and quantification of the clinical workflow contributes to the accurate assessment of the expected time savings in report TAT after deployment of an AI triage device.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Thompson YLE, Fergus J, Chung J, et al. Impact of Artificial Intelligence Triage on Radiologist Report Turnaround Time: Real-World Time Savings and Insights From Model Predictions. J Am Coll Radiol. 2025. PMID: 41026071. doi:10.1016/j.jacr.2025.07.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。