吸气-呼气相胸部CT的临床实施:定义诊断质量及检测肺移植后FEV1下降的质量标准

Clinical Implementation of Inspiratory-Expiratory Chest CT: Defining Quality Criteria for Diagnostic Quality and Detection of Concurrent FEV1 Decline following Lung Transplantation.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

研究回顾性评估192例肺移植患者共603次吸气-呼气相胸部CT,通过呼气相气管形态分级及CT肺容积与肺功能对比定义诊断充分性标准。气管凸出形态占29%(175/613),导致呼气容积高估;气管凹陷时CT与肺功能容积相关性改善。基线空气潴留50%在形态以凹陷或平坦且容积变化≥1.0 L的研究中诊断CLAD特异度82.6%、敏感度34.0%;空气潴留增加20%预测FEV1下降10%的特异度92.1%、敏感度20.0%。

要点

  • 呼气相气管形态以凸出为主时CT高估呼气容积,评估空气潴留前应确认气管凹陷或平坦。
  • 气管凹陷时CT与肺功能肺容积相关性改善,支持将其作为呼气相诊断充分性标准。
  • 空气潴留预测CLAD及FEV1下降特异度高但敏感度低,阴性不能排除病变。

核心结论

  • 呼气相气管形态可用于评估呼气相CT的诊断充分性;空气潴留增加对预测FEV1下降和诊断CLAD进展高度特异但敏感度不高,有助于CLAD的诊断和监测。

研究设计与样本

  • 回顾性评估作者所在机构2020年3月至2023年11月连续肺移植后吸气-呼气相胸部CT,共192例患者(平均年龄57.2岁±13.3[SD],121例男性)603次检查;采用深度学习算法测量肺容积和体素级空气潴留,以肺功能数据为参考。

关键影像表现/征象

  • 呼气相气管形态以凸出为主见于29%(175/613)的CT检查,这些检查中呼气容积被高估。
  • 气管凹陷时CT与肺功能肺容积测量相关性改善。

诊断标准与关键数值

  • 气管形态以凹陷或平坦为主且容积变化≥1.0 L时,基线空气潴留50%诊断CLAD的敏感度34.0%、特异度82.6%。
  • 空气潴留增加20%预测同期FEV1下降10%的敏感度20.0%、特异度92.1%。

临床应用与阅片要点

  • 阅片时应评估呼气相气管形态,凸出为主提示呼气容积高估,需谨慎解读空气潴留。
  • 报告空气潴留时结合气管形态和CT-肺功能容积变化判断诊断充分性。
  • 空气潴留增加高度特异但敏感度低,阴性结果不能排除CLAD或FEV1下降。

局限性

  • 原文为回顾性评估。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To define criteria for evaluating the diagnostic adequacy of expiratory CT and use these criteria to evaluate how expiratory quality affects the performance of quantitative air trapping in predicting the presence and progression of chronic lung allograft dysfunction (CLAD). Materials and Methods Consecutive post-lung transplantation inspiratory-expiratory chest CT scans acquired at the authors' institution between March 2020 and November 2023 were retrospectively evaluated for diagnostic adequacy by grading the tracheal morphology on expiratory CT scans and comparing CT lung volume measurements with spirometry data. Lung volumes and voxelwise air trapping were measured using a deep learning algorithm. Air trapping was compared against changes in spirometry data at baseline and follow-up using Pearson correlation and receiver operating characteristic curve analysis. Results A total of 603 inspiratory-expiratory chest CT scans in 192 patients who underwent lung transplantation (mean age, 57.2 years ± 13.3 [SD]); 121 male patients) were evaluated. Tracheal morphology was identified as predominantly convex on 29% (175 of 613) of the CT scans, resulting in an overestimation of the expiratory volume in these studies. The correlation of the lung volume measurements between CT and spirometry improved with tracheal concavity. A baseline air trapping level of 50% had 82.6% specificity and 34.0% sensitivity for diagnosing CLAD on studies with predominantly concave or flat morphology and a volume change of 1.0 L or greater. A 20% increase in air trapping resulted in 92.1% specificity and 20.0% sensitivity for a concurrent 10% decline in the forced expiratory volume in 1 second (FEV1). Conclusion Tracheal morphology was used to assess the diagnostic adequacy of expiratory phase CT. Increased air trapping was highly specific, but not very sensitive, for predicting an FEV1 decline and helped in the diagnosis and monitoring of CLAD progression. Keywords: CT, CT-Quantitative, Pulmonary, Lung, Physiological Studies, QA/QC, Transplantation, Technology Assessment, Quality Assurance, Artificial Intelligence, Air Trapping, Bronchiolitis Obliterans, Lung Transplant Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Sankaran R, Cypro A, Hasenstab K, et al. Clinical Implementation of Inspiratory-Expiratory Chest CT: Defining Quality Criteria for Diagnostic Quality and Detection of Concurrent FEV1 Decline following Lung Transplantation. Radiol Cardiothorac Imaging. 2025. PMID: 40932379. doi:10.1148/ryct.240468