文献速递心血管外周血管MR

压缩SENSE联合深度学习重建加速胸部主动脉非对比增强MR血管成像

Accelerating non-contrast MR angiography of the thoracic aorta using compressed SENSE with deep learning reconstruction.
PubMed 文献 · Eur J Radiol · 2025-09-02

前瞻性单中心研究纳入40名志愿者,在3T下采用CS加速因子4(参考标准)和8采集3D REACT,CS8分别用标准法和CS-AI重建。CS8扫描时间中位数较CS4缩短44%,CS8-AI与CS4主动脉直径测量一致性极佳,主观图像质量与CS4相当或更高。

要点

  • CS8-AI可将胸部主动脉3D REACT扫描时间从8:41 min缩短至4:52 min(降低44%)。
  • CS8-AI与CS4主动脉直径测量平均差异<0.2 mm,测量方差较CS8低40-50%。
  • CS8主观图像质量评分低于CS4,CS8-AI与CS4相当或更高。

核心结论

  • 基于深度学习的重建使胸部主动脉REACT采集在不到5分钟内完成,同时保持高图像质量和极佳的测量可重复性。

研究设计与样本

  • 前瞻性单中心研究,40名志愿者,3T下ECG和导航门控触发3D REACT,CS加速因子4(CS4;参考标准)和8(CS8),CS8数据分别用标准法和CS-AI重建。

关键影像表现/征象

  • CS8-AI较CS8降低与CS4的平均绝对偏差(0.67 vs 0.77 mm;P=0.003)。
  • CS8-AI测量方差较CS8低40-50%(评估者间/评估者内:P<0.001),与CS4相当。
  • CS8主观图像质量评分显著低于CS4(3.70[3.33-4.00] vs 4.25[3.90-4.50];P<0.001)。
  • CS8-AI主观图像质量评分与CS4相当或更高(4.40[4.00-4.70];P=0.076)。
  • 强制选择比较中CS4优于CS8(90% vs 2.5%;P<0.001),CS4与CS8-AI之间无偏好(42.5% vs 37.5%;P>0.999)。

诊断标准与关键数值

  • 所有技术主动脉直径测量一致性极佳(平均差异<0.2 mm;P>0.999)。
  • CS8-AI与CS4的平均绝对偏差为0.67 mm,CS8与CS4为0.77 mm(P=0.003)。
  • CS8-AI测量方差较CS8低40-50%(评估者间/评估者内:P<0.001)。

临床应用与阅片要点

  • CS8-AI重建可在不到5分钟内完成胸部主动脉REACT采集,图像质量与CS4相当或更高。
  • CS8标准重建主观图像质量低于CS4,CS8-AI可弥补该差距。
  • CS8-AI与CS4主动脉直径测量一致性极佳,测量可重复性与CS4相当。

局限性

  • 本研究为前瞻性单中心研究,样本为40名志愿者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: REACT (Relaxation-Enhanced Angiography without ContrasT) is a reliable non-contrast magnetic resonance angiography for imaging of the thoracic aorta but remains time-consuming. This study evaluates acceleration of image acquisition using compressed sensing and parallel imaging (Compressed SENSE, CS) combined with deep learning-based image reconstruction (CS-AI).

METHODS: In this prospective single-center study, 40 volunteers underwent ECG- and navigator-triggered 3D REACT at 3 T using CS acceleration factor 4 (CS4; reference standard) and 8 (CS8). CS8 data were reconstructed with standard and CS-AI methods (CS8-AI). Two radiologists measured aortic diameters, rated subjective image quality and performed pairwise comparisons. Additionally, objective image quality metrics were calculated.

RESULTS: Median scan time was reduced by 44 % (CS4: 8:41 min; CS8/CS8-AI: 4:52 min). All techniques showed excellent agreement in aortic diameter measurements (mean differences < 0.2 mm; P > 0.999). CS8-AI demonstrated reduced mean absolute deviation from CS4 compared to CS8 (0.67 vs. 0.77 mm; P = 0.003), and measurement variance was 40-50 % lower with CS8-AI than with CS8 (inter-/intrarater: P < 0.001), and comparable to CS4. CS8 showed significantly lower subjective image quality scores than CS4 (3.70[3.33-4.00] vs. 4.25[3.90-4.50]; P < 0.001), while CS8-AI showed comparable or higher scores (4.40[4.00-4.70]; P = 0.076). Forced-choice comparisons favored CS4 over CS8 (90 % vs. 2.5 %; P < 0.001), but no preference was observed between CS4 and CS8-AI (42.5 % vs. 37.5 %; P > 0.999). Objective metrics predominantly confirmed the subjective results.

CONCLUSION: Deep learning-based reconstruction enables the acquisition of REACT of the thoracic aorta in less than five minutes while preserving high image quality and maintaining excellent measurement reproducibility.

来源:Eur J Radiol,查看原文。版权归原作者所有。