基于18F-FDG PET/CT影像组学的不同机器学习模型预测病理高侵袭性非小细胞肺癌
本研究回顾性纳入两个医疗中心1459例cT1期(肿瘤≤3 cm)非小细胞肺癌患者,提取PET和CT的影像组学特征并构建Rad-score,结合临床影像特征建立联合模型,比较LR、RF、SVM和XGBoost算法。XGBoost联合模型预测病理高侵袭性表现最佳,外部验证AUC为0.903。
要点
- cT1期NSCLC病理高侵袭性预测中,XGBoost联合模型外部验证AUC达0.903。
- 影像组学模型基于11个特征,外部验证AUC为0.829。
- 联合模型整合临床影像特征与Rad-score,校准良好且净获益高。
核心结论
- XGBoost联合模型在预测cT1期NSCLC病理高侵袭性方面表现出良好性能,外部验证AUC为0.903。
研究设计与样本
- 回顾性研究,纳入两个医疗中心1459例cT1期NSCLC患者(病理高侵袭性633例,非高侵袭性826例),从PET和CT各提取1145个影像组学特征。
诊断标准与关键数值
- 影像组学模型基于11个影像组学特征构建,训练集AUC 0.851、内部验证集AUC 0.859、外部验证集AUC 0.829;XGBoost联合模型对应AUC分别为0.958、0.919、0.903。
临床应用与阅片要点
- 作者认为XGBoost联合模型在预测cT1期NSCLC病理高侵袭性方面表现出良好性能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to develop and validate machine learning models integrating clinicoradiological and radiomic features from 2-[18 F]-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) to predict pathological high invasiveness in cT1-sized (tumor size ≤ 3 cm) non-small cell lung cancer (NSCLC).
MATERIALS AND METHODS: We retrospectively reviewed 1459 patients with NSCLC (633 with pathological high invasiveness and 826 with pathological non-high invasiveness) from two medical centers. Patients with cT1-sized NSCLC were included. 1145 radiomic features were extracted per modality (PET and CT) from each patient. Optimal predictors were selected to construct a radiomics score (Rad-score) for the PET/CT radiomics model. A combined model incorporating significant clinicoradiological features and the Rad-score was developed. Logistic regression (LR), random forest (RF), support vector machine (SVM), and extreme gradient boosting (XGBoost) algorithms were used to train the combined model. Model performance was assessed the area under the receiver operating characteristic (ROC) curve (AUC), calibration curve, and decision curve analysis (DCA). Shapley Additive Explanations (SHAP) was applied to visualize the prediction process.
RESULTS: The radiomics model was built using 11 radiomic features, achieving AUCs of 0.851 (training), 0.859 (internal validation), and 0.829 (external validation). Among all models, the XGBoost combined model demonstrated the best predictive performance, with AUCs of 0.958, 0.919, and 0.903, respectively, along with good calibration and high net benefit.
CONCLUSION: The XGBoost combined model showed strong performance in predicting pathological high invasiveness in cT1-sized NSCLC.
引用
- Li Y, Shen MJ, Yi JW, et al. 18F-FDG PET/CT-based Radiomics Analysis of Different Machine Learning Models for Predicting Pathological Highly Invasive Non-small Cell Lung Cancer. Acad Radiol. 2025. PMID: 40967950. doi:10.1016/j.acra.2025.08.063