文献速递头颈技术与安全PETCT

uEXPLORER全身PET/CT在鼻咽癌中的潜在价值:动态成像与动力学参数

Potential values of uEXPLORER total-body PET/CT in nasopharyngeal carcinoma: dynamic imaging and kinetic parameters.
PubMed 文献 · Eur J Radiol · 2025-09-16

前瞻性纳入56例鼻咽癌患者,治疗前行1小时动态全身PET/CT(uEXPLORER)采集,评估SUV及Patlak动力学参数。原发灶时间-活性曲线呈持续上升趋势,SUVmax与Ki、k3强相关;34枚超声活检淋巴结中10枚转移、24枚炎症,Ki图像对转移淋巴结的病灶-背景比高于PET图像。

要点

  • 鼻咽癌原发灶1小时内时间-活性曲线持续上升,SUVmean离散度逐渐增大。
  • 原发灶SUVmax与Ki强相关(r=0.903),与k3相关(r=0.660)。
  • 转移性与炎性淋巴结的SUVmax、Ki、k2、k3有显著差异,K1无显著差异。

核心结论

  • 全身PET/CT通过注射后第一小时的[18F]FDG摄取揭示肿瘤异质性和代谢特征,动力学参数和Ki图像可能有助于鉴别鼻咽癌的恶性与炎性淋巴结。

研究设计与样本

  • 前瞻性研究,纳入56例鼻咽癌患者,治疗前行1小时动态全身PET/CT(uEXPLORER)采集,评估SUV及Patlak动力学参数(Ki、K1、k2、k3)。

关键影像表现/征象

  • 原发灶时间-活性曲线呈持续上升趋势,SUVmean离散度逐渐增大;每个患者采集97帧SUVmean图像。

诊断标准与关键数值

  • 原发灶SUVmax与Ki强相关(r=0.903,P=0.001),与k3相关(r=0.660,P<0.001);转移性与炎性淋巴结的SUVmax、Ki、k2、k3差异显著(分别为p<0.0001、p<0.01、p<0.01、p<0.0001),K1无显著差异;Ki图像病灶-背景比高于PET图像(p<0.05)。

临床应用与阅片要点

  • 对鼻咽癌N分期重要的、[18F]FDG摄取轻至中度的可疑转移小淋巴结行超声引导活检;动力学参数和Ki图像可能有助于鉴别转移性与炎性淋巴结。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To explore the dynamic imaging and kinetic parameters of total-body positron-emission tomography/computed tomography (TB-PET/CT) in nasopharyngeal carcinoma (NPC).

METHODS: Fifty-six NPC patients were prospectively enrolled and underwent pretreatment 1-hour dynamic TB-PET/CT (uEXPLORER) acquisition. Standardized uptake values (SUVs) and Patlak-based quantitative kinetic parameters, including glucose metabolic rate (Ki), glucose transport rate of flow-in and flow-out between blood and tissues (K1 and k2), and tissue glucosamine-6-phosphatization rate (k3) were assessed. The suspected metastatic small lymph nodes with mild-to-moderate [18F] FDG uptake and those important for the N staging of tumor underwent ultrasound-guided biopsy, and the lesion-to-background ratio (LBR) in TB-PET images and Ki images were compared.

RESULTS: In total, 97 frame of SUVmean images were collected in each patient. The time‒activity curves (TAC) of primary lesions showed a continuous upward trend. The SUVmean dispersion among primary lesions increased gradually. SUVmax correlated strongly with Ki and k3 (r = 0.903 and 0.660, P = 0.001 and < 0.001, respectively) in primary lesions. Out of the 34 cervical lymph nodes biopsied using ultrasound, 10 were confirmed as metastases, and 24 involved inflammations. SUVmax, Ki, k2, and k3 were significantly different (p < 0.0001, p < 0.01, p < 0.01, and p < 0.0001 respectively) between metastatic lymph nodes and inflamed lymph nodes, while K1 had no significant difference. Ki images had higher LBR than PET images in metastatic lymph nodes conspicuity (p < 0.05).

CONCLUSION: TB-PET/CT uncovered tumor heterogeneity and metabolic characteristics via [18F] FDG uptake during the first hour after injection. Kinetic parameters and Ki images may help in discriminating between malignant and inflammatory lymph nodes in Nasopharyngeal Carcinoma.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hu YY, Yang ZC, Liang LP, et al. Potential values of uEXPLORER total-body PET/CT in nasopharyngeal carcinoma: dynamic imaging and kinetic parameters. Eur J Radiol. 2025. PMID: 40974693. doi:10.1016/j.ejrad.2025.112422

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。