文献速递神经介入CTDSA

高分辨率锥形束CT用于评估未破裂颅内动脉瘤血流导向装置植入后内皮化

Application of High-Resolution Conebeam CT for Evaluation of Endothelialization after Flow Diverter Implantation for Unruptured Intracranial Aneurysms.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-03-04

回顾性分析2019年3月至2023年10月378例患者446个未破裂颅内动脉瘤植入的402枚血流导向装置,用高分辨率锥形束CT和数字减影血管造影评估术后3、6、12个月内皮化。12个月时85.1%装置内皮化良好、14.9%内皮化不良;年龄≥60岁、瘤腔流入角大、载瘤动脉过度迂曲和支架贴壁不全是不良内皮化的独立危险因素。

要点

  • 高分辨率锥形束CT可评估血流导向装置内皮化和支架内狭窄。
  • 12个月时85.1%装置内皮化良好,14.9%内皮化不良。
  • 支架贴壁不全者不良内皮化风险约为无贴壁不全者的10.967倍。

核心结论

  • 高分辨率锥形束CT能准确评估未破裂颅内动脉瘤血流导向装置植入后的内皮化和支架内狭窄。
  • 年龄≥60岁、瘤腔流入角大、载瘤动脉过度迂曲和支架贴壁不全是内皮化不良的独立危险因素。

研究设计与样本

  • 回顾性分析2019年3月至2023年10月接受血流导向装置治疗的未破裂颅内动脉瘤患者的临床和影像资料。
  • 共378例患者、446个动脉瘤、402枚血流导向装置。
  • 术后即刻用高分辨率锥形束CT评估支架贴壁,术后3、6、12个月用高分辨率锥形束CT和数字减影血管造影评估内皮化。
  • 采用多因素logistic回归分析筛选内皮化不良的相关因素。

关键影像表现/征象

  • 术后即刻高分辨率锥形束CT显示41枚血流导向装置支架贴壁不全。
  • 术后12个月动脉瘤闭塞率为84.8%(378/446),8.7%(35/402)的血流导向装置出现支架内狭窄。
  • 术后12个月343枚(85.1%)血流导向装置内皮化良好,59枚(14.9%)内皮化不良。

诊断标准与关键数值

  • 多因素logistic回归显示年龄≥60岁与内皮化不良相关(OR=2.209;95%CI,1.053-4.635;P=.04)。
  • 瘤腔流入角大与内皮化不良相关(OR=1.102;95%CI,1.071-1.135;P<.001)。
  • 载瘤动脉过度迂曲与内皮化不良相关(OR=9.402;95%CI,1.141-77.479;P=.04)。
  • 支架贴壁不全与内皮化不良相关(OR=10.967;95%CI,4.290-28.035;P<.001)。

临床应用与阅片要点

  • 术后即刻可用高分辨率锥形束CT评估支架贴壁情况,术后3、6、12个月可联合高分辨率锥形束CT与数字减影血管造影评估内皮化和支架内狭窄。
  • 阅片时需关注年龄≥60岁、瘤腔流入角大、载瘤动脉过度迂曲及支架贴壁不全等内皮化不良的相关因素。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Although high-resolution conebeam CT (HR-CBCT) is used for immediate evaluation of stent apposition, studies using this technique to evaluate flow diverter (FD) endothelialization during follow-up are limited. The study aims to investigate the potential of HR-CBCT in assessing FD endothelialization and identify factors influencing poor endothelialization.

MATERIALS AND METHODS: The clinical and imaging data of patients with unruptured intracranial aneurysms (UIAs) treated by FDs from March 2019 to October 2023 were retrospectively analyzed. HR-CBCT was used for immediate evaluation of stent apposition, and FD endothelialization at 3, 6, and 12 months postimplantation was evaluated by using HR-CBCT and digital subtraction angiography. Multivariate logistic regression analysis was used to identify factors associated with poor endothelialization.

RESULTS: Among 402 FDs implanted for 446 aneurysms in 378 patients, 41 showed incomplete stent apposition (ISA) in postimplantation HR-CBCT scans. The aneurysm-occlusion rate at 12 months postimplantation was 84.8% (378/446), with 8.7% (35/402) of the FDs exhibiting in-stent stenosis (ISS). At 12 months postimplantation, 343 (85.1%) FDs showed good endothelialization, while 59 (14.9%) exhibited poor endothelialization. Multivariate logistic regression analysis identified age ≥60 years (OR = 2.209; 95% CI, 1.053-4.635; P = .04), a large aneurysm lumen inflow angle (OR = 1.102; 95% CI, 1.071-1.135; P < .001), parent artery excessive tortuosity (OR = 9.402; 95% CI, 1.141-77.479; P = .04), and ISA (OR = 10.967; 95% CI, 4.290-28.035; P < .001) as independent risk factors for poor endothelialization.

CONCLUSIONS: HR-CBCT can accurately evaluate FD endothelialization and ISS of UIAs after FD implantation. Age ≥60 years, a large aneurysm lumen inflow angle, parent artery excessive tortuosity, and ISA are independent risk factors for poor endothelialization.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Shi S, Zhang Z, Long S, et al. Application of High-Resolution Conebeam CT for Evaluation of Endothelialization after Flow Diverter Implantation for Unruptured Intracranial Aneurysms. AJNR Am J Neuroradiol. 2026. PMID: 40925683. doi:10.3174/ajnr.A8997

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。