快速三维轮状采集与常规并行成像在脑磁共振血管造影中评估颅内动脉瘤的比较
回顾性纳入50例未破裂脑动脉瘤患者,在3T磁共振上比较快速三维轮状采集(Fast 3Dw)与常规并行成像(PI)的三维时间飞跃法磁共振血管造影。Fast 3Dw检查时间显著缩短(171.5±4.9秒 vs 383.8±13.2秒,p<0.05),信噪比更高(50.0±14.2 vs 46.6±12.9,p<0.05),对比噪声比、动脉瘤直径、血管直径及定性图像质量均无显著差异;作者认为该方法可能成为常规脑磁共振血管造影的可行替代方案。
要点
- Fast 3Dw检查时间171.5±4.9秒,显著短于PI的383.8±13.2秒(p<0.05)。
- Fast 3Dw信噪比50.0±14.2,显著高于PI的46.6±12.9(p<0.05)。
- 两种技术对比噪声比、动脉瘤直径、血管直径及定性图像质量无显著差异。
核心结论
- Fast 3Dw技术较PI显著缩短脑磁共振血管造影检查时间,同时维持图像质量和诊断准确性,可能成为常规脑磁共振血管造影的可行替代方案。
研究设计与样本
- 回顾性研究纳入50例未破裂脑动脉瘤患者,在3T磁共振扫描仪上分别采用PI或Fast 3Dw技术行三维时间飞跃法磁共振血管造影。
关键影像表现/征象
- Fast 3Dw检查时间171.5±4.9秒,PI为383.8±13.2秒(p<0.05)。
- Fast 3Dw信噪比50.0±14.2,PI为46.6±12.9(p<0.05)。
- 两种技术对比噪声比无显著差异。
- 两种技术动脉瘤直径和血管直径无显著差异。
- 血管清晰度、伪影及诊断信心水平在两种技术间无显著差异。
诊断标准与关键数值
- 定性图像评估采用5分制,评估血管清晰度、伪影及诊断信心水平。
- 定量评估包括信噪比、对比噪声比、动脉瘤直径和血管直径。
- 统计方法采用t检验、Wilcoxon符号秩检验和加权kappa统计。
临床应用与阅片要点
- Fast 3Dw可显著缩短脑磁共振血管造影检查时间至171.5±4.9秒,同时维持图像质量和诊断准确性。
- 作者认为Fast 3Dw可能成为常规脑磁共振血管造影的可行替代方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aimed to evaluate the effectiveness of the Fast 3D wheel (Fast 3Dw) technique in cerebral magnetic resonance angiography (MRA) and compare it with the conventional parallel imaging (PI) technique. The primary objective was to determine whether Fast 3Dw could reduce the examination time while maintaining image quality and diagnostic accuracy in patients with cerebral aneurysms.
METHODS: This retrospective study included 50 patients with unruptured cerebral aneurysms who underwent 3D time-of-flight MRA using either PI or Fast 3Dw techniques on a 3T magnetic resonance imaging scanner. The image quality was quantitatively assessed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), aneurysm diameter, and vessel diameter. Qualitative image assessments included vascular clarity, artifacts, and diagnostic confidence level and were evaluated using a 5-point scale. Statistical comparisons were performed using t-tests, Wilcoxon signed-rank tests, and weighted kappa statistics.
RESULTS: The mean examination time for Fast 3Dw (171.5 ± 4.9 s) was significantly shorter than that for PI (383.8 ± 13.2 s; p < 0.05). Fast 3Dw exhibited a significantly higher SNR (50.0 ± 14.2) than PI (46.6 ± 12.9; p < 0.05), while CNR showed no significant difference between the two techniques. No significant differences in aneurysm diameters and vessel diameters were observed between the two methods. Qualitative evaluations demonstrated no significant differences in vascular clarity, artifacts, and diagnostic confidence levels between the two methods.
CONCLUSION: The Fast 3Dw technique significantly reduces examination time while maintaining image quality and diagnostic accuracy in cerebral MRA compared to PI. This method may be a viable alternative for routine cerebral MRA in clinical practice.
引用
- Hanamatsu S, Murayama K, Ohno Y, et al. Fast 3D wheel acquisition versus conventional parallel imaging in cerebral magnetic resonance angiography for the evaluation of intracranial aneurysms : Original Article. Neuroradiology. 2025. PMID: 40974398. doi:10.1007/s00234-025-03776-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。