灌注血管造影在再灌注缺血性卒中患者中的应用:区分良好与不良结局
该研究基于MR CLEAN登记中血管内治疗后成功再灌注(eTICI≥2b)的743例前循环闭塞患者,从术后DSA时间-强度曲线计算毛细血管灌注参数。eTICI评分与90天良好功能结局无关,而较短的MTT和Tmax与良好功能结局相关,DSA-CBV和DSA-CBF与mRS无显著关联。定量DSA灌注参数可提供再灌注状态的额外信息,可能有助于区分良好与不良功能结局。
要点
- 成功再灌注(eTICI≥2b)患者中,eTICI评分与90天良好功能结局无关联。
- 术后DSA-derived MTT和Tmax较短与90天良好功能结局(mRS 0-2)独立相关。
- DSA-CBV和DSA-CBF与90天mRS无显著关联。
核心结论
- 定量DSA灌注参数提供再灌注状态的额外信息,可能有助于区分良好与不良功能结局。
研究设计与样本
- 回顾性队列研究,选自MR CLEAN登记,纳入ICA、M1或M2闭塞且EVT后成功再灌注(eTICI≥2b)患者743例(总5768例中),从术后DSA时间-强度曲线去卷积计算毛细血管灌注参数。
诊断标准与关键数值
- 成功再灌注定义为扩展TICI(eTICI)≥2b。
- 良好功能结局定义为90天mRS 0-2。
- MTT较短与良好功能结局相关,校正OR 1.25(95%CI 1.03-1.51)。
- DSA-CBV和DSA-CBF与mRS无显著关联。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The TICI score determines the reperfusion grade on DSA after endovascular treatment (EVT) in patients with acute ischemic stroke. Despite successful macrovascular reperfusion, almost one-half of patients have poor clinical outcomes. In addition to the large vessels, DSA also depicts the passage of contrast in the capillaries. We aim to study differences in DSA perfusion parameters generated from the time-intensity curves that might differentiate between good and poor clinical outcome in patients who achieved successful reperfusion.
MATERIALS AND METHODS: Patients from the MR CLEAN Registry with an ICA, M1, and M2 occlusion, and successful reperfusion extended TICI (eTICI ≥2b) were selected. Perfusion parameters of the capillary pixels were computed on post-EVT DSA by deconvolving the time-intensity curve with the arterial input function obtained from the ICA. We extracted 4 perfusion parameters: CBV, CBF, time-to-maximum (Tmax), and mean transit time (MTT). The association between the perfusion parameters and favorable functional outcome at 90 days (0-2 mRS) was analyzed using logistic regression with adjustments for prognostic patient characteristics including eTICI.
RESULTS: In total, 743 of 5768 patients were included. There was no association between eTICI scores and favorable functional outcome. In contrast, a shorter MTT and Tmax were associated with favorable functional outcome (adjusted OR, 1.25 [95% CI, 1.03-1.51], 1.39 [95% CI, 1.06-1,82]). DSA-CBV and DSA-CBF were not significantly associated with mRS.
CONCLUSIONS: Quantifying DSA perfusion parameters provides additional information about reperfusion status and could contribute to differentiating between favorable and unfavorable functional outcomes. The code for producing the quantitative digital subtraction perfusion angiography is publicly available at: https://github.com/RuishengSu/perfDSA.
引用
- van der Sluijs PM, Su R, Schoon BA, et al. Perfusion Angiography in Reperfused Patients with Ischemic Stroke: Differentiating between Favorable and Unfavorable Outcome. AJNR Am J Neuroradiol. 2026. PMID: 41015542. doi:10.3174/ajnr.A8936
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。